Murat Ayaz

Prof. Dr. Murat Ayaz

Electric and Energy, Kocaeli University, Kocaeli, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Simulation Modelling Practice and Theory
Verified
Journal Article
Closed access
Serkan SezenSerkan Sezen
Serkan Sezen
EKErcument Karakas
Ercument Karakas
Kadir YılmazKadir Yılmaz
Kadir Yılmaz
Murat AyazMurat Ayaz
Murat Ayaz

22 March 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ABALI BAKBAK
ALI BAKBAK
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
Murat AyazMurat Ayaz
Murat Ayaz
MAMert Altintas
Mert Altintas
EMErkan Mese
Erkan Mese
Direct grid coupling of permanent magnet synchronous generators (PMSG) for wind energy conversion systems provides certain advantages with the penalties of maximum power point tracking (MPPT) and reactive power control. This article proposes a novel PMSG design philosophy such that optimizing PMSG design at the initial stage would compensate for the drawbacks arising from the lack of an MPPT algorithm. Also, the ability to maintain a high PF across a wide range of operating power levels is investigated by considering reactive power in the design process. In this article, optimization of slot/pole combination is described for direct grid coupled PMSGs to extract as much energy as possible according to wind data. A new benchmark, adequacy factor, is presented to determine the slot/pole combination. Variation of the reactive power is theoretically analyzed. A relationship is established between induced electromotive force, synchronous inductance values of machines, and the PF. Fixed and variable speed operations of PMSGs are compared in terms of annual energy yield. Finally, theoretical analyses are validated through laboratory testing of prototype generators.

1 April 2016 in Electric Power Systems Research
Verified
Journal Article
Closed access
Murat AyazMurat Ayaz
Murat Ayaz
EMErkan Mese
Erkan Mese

24 August 2021 in IEEE Access
Verified
Journal Article
Open access
ABALI BAKBAK
ALI BAKBAK
MAMert Altintas
Mert Altintas
Murat AyazMurat Ayaz
Murat Ayaz
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
MBMutlu Boztepe
Mutlu Boztepe
EMErkan Mese
Erkan Mese
In this study, a dual-port wind-energy conversion system has been proposed. A double-fed permanent-magnet synchronous generator (DFPMSG) forms the central part of the system, where the concentrated single-layer winding configuration of the generator enables electric and magnetic isolation between the ports. DFPMSG has two three-phase terminals out of the stator; one is connected directly to the grid, whereas the other is tied to the grid through a back-to-back converter. This study investigates design issues caused by the DFPMSG port with a direct grid connection. The unique design issues of the proposed system include determining the slot/pole combination using wind data and determining the minimum reactive power requirement for the port with a direct grid connection. Next, the load-sharing capability among the ports of the proposed system is presented through a detailed investigation of three schemes. Experimental work is presented for a 5-kW prototype DFPMSG system to illustrate the isolation among the ports, minimized reactive power demand on the port with direct grid connection, and load-sharing ability among the ports for different control schemes.

1 October 2024 in Materials Research Express
Verified
Journal Article
Open access
YKYiğit Karabulut
Yiğit Karabulut
EMErkan Meşe
Erkan Meşe
Murat AyazMurat Ayaz
Murat Ayaz
SASerkan Aktas
Serkan Aktas
This study aims to compare the soft magnetic composite (SMC) and grain-oriented (GO) steel stator axial flux permanent-magnet synchronous machine (AFPMSM) in terms of performance and iron losses. Stator cores are manufactured using both materials to perform experimental performance tests. The produced machines are designed for pump propulsion systems in left ventricular assist devices as an application area. The machines are modeled with several analytical equations, and iron losses and performance tests are carried out with AFPMSMs, finite element methods, and experimental setups. Our findings show that the torque density is higher in the GO steel stator AFPMSMs that can produce 15.07 percent more torque. GO steel material experimentally has 20.33 percent less iron loss as SMC material since the loss value per kilogram for SMC material is higher than that for GO steel. In addition, the saturation value of the SMC material is lower than that of the GO material according to the magnetic flux density value.

7 February 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YKYiğit Karabulut
Yiğit Karabulut
UAUfuk Ayhan
Ufuk Ayhan
SASerkan Aktas
Serkan Aktas
Murat AyazMurat Ayaz
Murat Ayaz
EMErkan Meşe
Erkan Meşe
This paper addresses the design and thermal analysis of Axial Flux Permanent Magnet Synchronous Machines (AFPMSMs) integrated into flow left ventricular assist devices (LVADs). Allowed temperature rise limitation due to medical application was the primary motivation of this research. Thermal challenges are further elevated due to the limited volume, which increases the thermal loading of the motor. Furthermore, effective cooling of both the rotor and stator was achieved, which is an innovative aspect of this work. Within the scope of this study, the thermal aspects of AFPMSMs specifically for LVAD pumps were examined, and their validations were carried out through analytical calculations and simulation studies along with some experimental work. It was validated by the FEA that the temperature of the fluid at the LVAD pump inlet under rated load increased by only 0.04°C. Therefore, the pump design presented does not pose any risks to the patient. Subsequently, to validate the design, an AFPMSM prototype was produced and tested in a laboratory environment. These tests showed that under the rated load, the winding temperature increase was 26.5°C, and the outer case temperature increase was 15.1°C. These results are consistent with both analytical and simulation results. This study demonstrated that the LVAD pump design is thermally suitable and that the established analytical equations are accurate in both simulation and experimental tests. Additionally, the novel integration of AFPMSM and pump yielded significantly higher current-carrying capacity due to the devised effective cooling mechanism.