Direct grid coupling of permanent magnet synchronous generators (PMSG) for wind energy conversion systems provides certain advantages with the penalties of maximum power point tracking (MPPT) and reactive power control. This article proposes a novel PMSG design philosophy such that optimizing PMSG design at the initial stage would compensate for the drawbacks arising from the lack of an MPPT algorithm. Also, the ability to maintain a high PF across a wide range of operating power levels is investigated by considering reactive power in the design process. In this article, optimization of slot/pole combination is described for direct grid coupled PMSGs to extract as much energy as possible according to wind data. A new benchmark, adequacy factor, is presented to determine the slot/pole combination. Variation of the reactive power is theoretically analyzed. A relationship is established between induced electromotive force, synchronous inductance values of machines, and the PF. Fixed and variable speed operations of PMSGs are compared in terms of annual energy yield. Finally, theoretical analyses are validated through laboratory testing of prototype generators.
In this study, a dual-port wind-energy conversion system has been proposed. A double-fed permanent-magnet synchronous generator (DFPMSG) forms the central part of the system, where the concentrated single-layer winding configuration of the generator enables electric and magnetic isolation between the ports. DFPMSG has two three-phase terminals out of the stator; one is connected directly to the grid, whereas the other is tied to the grid through a back-to-back converter. This study investigates design issues caused by the DFPMSG port with a direct grid connection. The unique design issues of the proposed system include determining the slot/pole combination using wind data and determining the minimum reactive power requirement for the port with a direct grid connection. Next, the load-sharing capability among the ports of the proposed system is presented through a detailed investigation of three schemes. Experimental work is presented for a 5-kW prototype DFPMSG system to illustrate the isolation among the ports, minimized reactive power demand on the port with direct grid connection, and load-sharing ability among the ports for different control schemes.
Unbalanced Magnetic Force (UMF) is a critical factor that significantly impacts vibration and overall performance in Permanent Magnet Synchronous Machines (PMSMs). This study investigates the influence of different fractional slot combinations on UMF behavior in PMSMs using finite element analysis (FEA). The focus is on the canceling and additive effects of UMFs generated by radial and circumferential stresses. Two PMSM configurations with slot and pole numbers differing by one—26 poles/27 slots and 28 poles/27 slots—are analyzed to evaluate the effect of varying pole configurations while keeping the slot count constant. The analysis employed the Maxwell stress tensor method to quantify the UMFs in these designs. The results underscore the critical role of the magnet configuration in determining UMF characteristics, providing essential insights for optimizing machine design to minimize vibration and enhance performance. These findings serve as a valuable reference for designing and operating high-performance fractional slot PMSMs, particularly for industrial and automotive applications.
21 July 2023 in IEEE Transactions on Industry Applications
The stability of a wind turbine-rotated synchronous generator must be maintained during a sudden change in wind speed or direction. In integral slot winding machines this task is taken care of by rotor damper windings. Tooth-coil permanent magnet generators cannot, however, have a damper winding in the rotor because of the high harmonic content of the air gap. In this paper, we study a possibility to stabilize PMSG damperless synchronous operation by dividing the generator stator winding into two parts - power winding (PW) and control winding (CW). We call this machine a dual-port PMSG (DPPMSG). The PW is directly connected to the grid. Therefore, the generator rotates, in average, at a fixed speed. On the other hand, the CW is connected to the grid through a four-quadrant power converter. The CW has three different tasks: It is responsible for the startup process, damping of speed oscillations and, of course, power generation. Electrical and magnetic decoupling of the winding sets is ensured by concentrated wound coils. The number of stator coils allocated to a winding set determines its power level. Different power levels of winding sets are analytically analyzed for wind gust speeds according to the IEC 61 400 standard. The results are verified by experimental tests.
30 August 2025 in International Journal of 3D Printing Technologies and Digital Industry
Günümüzde elektrikli araçların yaygınlaşması, bu alanda yapılan araştırmaları hızlandırmıştır. Hafif elektrikli araçlar, sürüş döngüleri sırasında belirli bir hız-tork karakteristiğine sahip olmaları ve düşük hızlarda yüksek tork gereksinimleri nedeniyle, bu tür araçlara uygun elektrik motorlarının belirlenmesi, tasarımı ve analizi kritik bir öneme sahiptir. Bu çalışma, hafif elektrikli araçlar için dış rotorlu, yüzey montajlı, sabit mıknatıslı senkron motor (SMSM) tasarımı ve analizini kapsamaktadır. Araştırma kapsamında, motor tasarımı ve analizine geçilmeden önce, araçların geometrik ve fiziksel parametreleri ile ayrıntılı bir sürüş döngüsü analizi gerçekleştirilmiştir. Araç modeline, pist koşullarına ve belirlenen sürüş döngüsüne göre motor tasarım gereksinimleri belirlenmiş ve bu doğrultuda optimizasyon yapılmıştır. Enerji verimliliği ve araç performansının ön planda olduğu hafif elektrikli araç yarışlarında kullanılmak üzere tasarlanan dış rotorlu SMSM, bu gereksinimlere göre optimize edilmiştir. Bu tasarım ve analiz süreci, motorun yüksek enerji verimliliği ve performansını sağlamayı hedeflemektedir.
17 March 2025 in International Journal of Computational and Experimental Science and Engineering
This study presents the development of a locally manufactured solenoid-coil-based door lock system for industrial washing machines, addressing the challenges associated with imported mechanisms such as high costs, frequent failures, and supply chain delays. The solenoid coil design is optimized using Finite Element Analysis (FEA) to achieve sufficient electromagnetic force while maintaining energy efficiency. The system operates at 24V DC with a nominal current of 0.65A, consuming 15W of power. Extensive testing demonstrated the system's reliability and robustness, including mechanical durability over 15,000 locking cycles, resilience under high temperature (up to 60°C) and humidity (90% RH) conditions, and resistance to forced entry. The results validate the system’s ability to meet the stringent demands of industrial environments while providing a cost-effective and reliable alternative. This development highlights the potential for scalable applications and contributes to advancing local manufacturing capabilities for industrial machinery components.