In order to reduce the computational complexity, and improve the pitch/roll estimation accuracy of the low-cost attitude heading reference system (AHRS) under conditions of magnetic-distortion, a novel linear Kalman filter, suitable for nonlinear attitude estimation, is proposed in this paper. The new algorithm is the combination of two-step geometrically-intuitive correction (TGIC) and the Kalman filter. In the proposed algorithm, the sequential two-step geometrically-intuitive correction scheme is used to make the current estimation of pitch/roll immune to magnetic distortion. Meanwhile, the TGIC produces a computed quaternion input for the Kalman filter, which avoids the linearization error of measurement equations and reduces the computational complexity. Several experiments have been carried out to validate the performance of the filter design. The results demonstrate that the mean time consumption and the root mean square error (RMSE) of pitch/roll estimation under magnetic disturbances are reduced by 45.9% and 33.8%, respectively, when compared with a standard filter. In addition, the proposed filter is applicable for attitude estimation under various dynamic conditions.
The design principle of the magnetic flux concentrators (MFCs) is studied by finite element method (FEM) and experiment. Firstly, the establishment process of the FEM model in Comsol Multiphysics is elaborated. Based on the simulation model, the magnetic amplification distributions of different shaped MFCs is compared, and the shape design principle of the MFC is obtained. Then, the influence of size parameters on the magnetic amplification of T, triangle, and trapezoid shaped MFCs is analyzed, and the size design principle of the MFCs is obtained. Additionally, the linear working range of the three MFCs is compared. To verify the simulation results, the MFCs are prepared using 1j79 permalloy. The experimental platform is established to acquire the magnetic gain under different magnetic fields. Based on the results, the linear working range of the MFCs is analyzed. And the influence of size parameters on the magnetic gain is tested. The experimental results are compared with the simulation ones to verify the validity of the model.
The cubature Kalman filter (CKF) is widely used in the application of GPS/INS integrated navigation systems. However, its performance may decline in accuracy and even diverge in the presence of process uncertainties. To solve the problem, a new algorithm named improved strong tracking seventh-degree spherical simplex-radial cubature Kalman filter (IST-7thSSRCKF) is proposed in this paper. In the proposed algorithm, the effect of process uncertainty is mitigated by using the improved strong tracking Kalman filter technique, in which the hypothesis testing method is adopted to identify the process uncertainty and the prior state estimate covariance in the CKF is further modified online according to the change in vehicle dynamics. In addition, a new seventh-degree spherical simplex-radial rule is employed to further improve the estimation accuracy of the strong tracking cubature Kalman filter. In this way, the proposed comprehensive algorithm integrates the advantage of 7thSSRCKF’s high accuracy and strong tracking filter’s strong robustness against process uncertainties. The GPS/INS integrated navigation problem with significant dynamic model errors is utilized to validate the performance of proposed IST-7thSSRCKF. Results demonstrate that the improved strong tracking cubature Kalman filter can achieve higher accuracy than the existing CKF and ST-CKF, and is more robust for the GPS/INS integrated navigation system.
The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.
ECG is one of the most effective medical tests for heart disease diagnosis, and R-peak detection is the first step in ECG interpretation. For wearable ECG signals, the difficulty of R-peak detection mainly lies in the interference of dynamic strong noise, and the limited hardware computational resources limit the use of some complex algorithms. Therefore, an adaptive threshold R-peak detection algorithm based on Brown’s exponential smoothing model is proposed in this paper. The algorithm selects features based on the morphological characteristics and occurrence law of R-peaks, updates the threshold parameters using the Brown exponential smoothing model, optimizes the smoothing coefficients in it using the relative error least squares method, corrects the smoothing ability of the observation error and the response speed to the change of the observation, so that the updated threshold can be more consistent with the R-peak detection. Finally the algorithm achieves 99.6% precision, 99.7% recall and 99.65% F1 score on the self-constructed ECG dataset, and compares with other R-peak detection algorithms to determine the superiority of the proposed algorithm in some performance metrics. It is demonstrated experimentally that the algorithm can adapt well to the strong noise environment and obtain satisfactory R-peak detection accuracy.