Weiyan Chen

Dr. Weiyan Chen

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PBPeng Bao
Peng Bao
HSHuaiqiang Sun
Huaiqiang Sun
ZWZhangyang (Atlas) Wang
Zhangyang (Atlas) Wang
YZYi Zhang
Yi Zhang
WXWenjun Xia
Wenjun Xia
HZHe Zhang
He Zhang
Over the past few years, dictionary learning (DL)-based methods have been successfully used in various image reconstruction problems. However, traditional DL-based computed tomography (CT) reconstruction methods are patch-based and ignore the consistency of pixels in overlapped patches. In addition, the features learned by these methods always contain shifted versions of the same features. In recent years, convolutional sparse coding (CSC) has been developed to address these problems. In this paper, inspired by several successful applications of CSC in the field of signal processing, we explore the potential of CSC in sparse-view CT reconstruction. By directly working on the whole image, without the necessity of dividing the image into overlapped patches in DL-based methods, the proposed methods can maintain more details and avoid artifacts caused by patch aggregation. With predetermined filters, an alternating scheme is developed to optimize the objective function. Extensive experiments with simulated and real CT data were performed to validate the effectiveness of the proposed methods. Qualitative and quantitative results demonstrate that the proposed methods achieve better performance than several existing stateof- the-art methods.

27 September 2023 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
WCWeiyan Chen
Weiyan Chen
HYHongliu Yang
Hongliu Yang
XBXiaoyang Bi
Xiaoyang Bi
RZRong Zheng
Rong Zheng
FZFusang Zhang
Fusang Zhang
Daqing ZhangDaqing Zhang
Daqing Zhang
Device-free indoor localization and tracking using commercial millimeter wave radars have attracted much interest lately due to their non-intrusive nature and high spatial resolution. However, it is challenging to achieve high tracking accuracy due to rich multipath reflection and occlusion in indoor environments. Static objects with non-negligible reflectance of mmWave signals interact with moving human subjects and generate time-varying multipath ghosts and shadow ghosts, which can be easily confused as real subjects. To characterize the complex interactions, we first develop a geometric model that estimates the location of multipath ghosts given the locations of humans and static reflectors. Based on this model, the locations of static reflectors that form a reflection map are automatically estimated from received radar signals as a single person traverses the environment along arbitrary trajectories. The reflection map allows for the elimination of multipath and shadow ghost interference as well as the augmentation of weakly reflected human subjects in occluded areas. The proposed environment-aware multi-person tracking system can generate reflection maps with a mean error of 15.5cm and a 90-percentile error of 30.3cm, and achieve multi-person tracking accuracy with a mean error of 8.6cm and a 90-percentile error of 17.5cm, in four representative indoor spaces with diverse subjects using a single mmWave radar.

29 May 2024
Verified
Conference Paper
Open access
ZCZhaoxin Chang
Zhaoxin Chang
FZFusang Zhang
Fusang Zhang
JXJie Xiong
Jie Xiong
WCWeiyan Chen
Weiyan Chen
Daqing ZhangDaqing Zhang
Daqing Zhang
Wireless signals have been widely utilized for human sensing. However, wireless sensing systems face a fundamental limitation, i.e., the wireless device must keep static during the sensing process. Also, when sensing fine-grained human motions such as respiration, the human target is required to stay stationary. This is because wireless sensing relies on signal variations for sensing. When device is moving or human body is moving, the signal variation caused by the target area (e.g., chest for respiration sensing) is mixed with the signal variation induced by device or other body parts, failing wireless sensing. In this paper, we propose MSense, a general solution to deal with motion interference from wireless device and/or human body, moving wireless sensing one step forward towards real-life adoption. We establish the sensing model by taking both device motion and interfering body motion into consideration. By extracting the effect of body and device motions through pure signal processing, the motion interference can be removed to achieve accurate target sensing. Comprehensive experiments demonstrate the effectiveness of the proposed scheme. The achieved solution is general and can be applied to different sensing tasks involving both periodic and aperiodic motions.

21 November 2024 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
ZCZhaoxin Chang
Zhaoxin Chang
FZFusang Zhang
Fusang Zhang
XMXujun Ma
Xujun Ma
PWPei Wang
Pei Wang
WCWeiyan Chen
Weiyan Chen
Daqing ZhangDaqing Zhang
Daqing Zhang
Fine-grained vital sign monitoring in emergency care is crucial for accurately assessing patient conditions, predicting disease progression, and formulating effective rescue plans. In non-hospital settings, limited equipment often necessitates manual observation of respiration and heartbeat, which can lead to significant errors. Contactless monitoring using wireless signals offers a promising alternative. Unlike traditional systems that require stationary devices for contactless sensing, handheld devices are more practical for rescuers during emergency care. However, sensing performance can be severely compromised by involuntary hand movements. Previous research has achieved respiration monitoring with handheld devices, but the randomness of hand motion still prevents reliable heartbeat monitoring. In this paper, we first demonstrate that the key to mitigating the effects of device motion lies in accurately estimating the motion direction. We then introduce a novel method that uses two static objects, i.e., corner reflectors, to precisely estimate the random motion direction of the device. These reflectors can be quickly and easily deployed by the rescuer before initiating vital sign monitoring, enabling a more thorough elimination of device motion effects. Comprehensive experiments validate the effectiveness of our solution using mmWave radar. Real-world tests demonstrate that our system can accurately monitor both respiration and heartbeat with handheld devices, significantly enhancing emergency medical response by improving the accuracy and feasibility of vital sign monitoring in urgent situations.

9 June 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
HYHongliu Yang
Hongliu Yang
DZDuo Zhang
Duo Zhang
XZXusheng Zhang
Xusheng Zhang
JXJie Xiong
Jie Xiong
ZFZizhou Fan
Zizhou Fan
Daqing ZhangDaqing Zhang
Daqing Zhang
Point clouds are a crucial data type for mmWave radar and are widely used in sensing applications such as human tracking and activity recognition. However, for indoor human sensing, the point clouds obtained by mmWave radar are often sparse. Previous studies attribute the sparsity to the limited sensing capabilities of mmWave radar, underestimating the impact of CFAR---a key algorithmic component of mmWave systems---on point cloud quality. Through empirical studies, we find that the spatial-based CFAR widely used in existing works suffers from a severe energy masking issue. This is because these algorithms work well when the target is far away enough to be approximated as a point. In short-range indoor sensing, the human body can not be considered as a point but an extended target, causing the spatial-based CFAR to calculate the noise power wrongly and accordingly a miss-generation of the point cloud. To fundamentally solve the problem, this paper proposes a temporal-based CFAR named ETCM-CFAR. We address multiple issues such as lacking initial noise power and the absence of a closed-form threshold solution to make the proposed algorithm work. Based on ETCM-CFAR, this paper proposes a point cloud generation system named mmPC. mmPC is implemented on three different types of commercial-off-the-shelf mmWave radars and extensive experiments demonstrate that mmPC significantly improves point cloud quality, increasing the number of cloud points by 148.6% compared to the state-of-the-art systems. Two representative sensing applications, i.e., fitness activity recognition and human-pet classification are further employed to demonstrate the effectiveness of mmPC on sensing.

4 December 2024
Verified
Conference Paper
Open access
ZCZhaoxin Chang
Zhaoxin Chang
XXXinyu Xue
Xinyu Xue
FZFusang Zhang
Fusang Zhang
JXJie Xiong
Jie Xiong
WCWeiyan Chen
Weiyan Chen
Daqing ZhangDaqing Zhang
Daqing Zhang
In recent years, wireless signals have been extensively investigated for contactless human respiration monitoring. However, most wireless sensing systems encounter challenges when the target exhibits body movements. In this demo, we present a solution to mitigate the impact of body motion on contactless respiration monitoring. By employing novel signal processing techniques, body motion can be first estimated and subsequently eliminated from the signal reflected signal by the chest. We prototype the proposed system using a MIMO mmWave radar. Evaluations in real-world environments demonstrate the effectiveness of the solution.