9 June 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Point clouds are a crucial data type for mmWave radar and are widely used in sensing applications such as human tracking and activity recognition. However, for indoor human sensing, the point clouds obtained by mmWave radar are often sparse. Previous studies attribute the sparsity to the limited sensing capabilities of mmWave radar, underestimating the impact of CFAR---a key algorithmic component of mmWave systems---on point cloud quality. Through empirical studies, we find that the spatial-based CFAR widely used in existing works suffers from a severe energy masking issue. This is because these algorithms work well when the target is far away enough to be approximated as a point. In short-range indoor sensing, the human body can not be considered as a point but an extended target, causing the spatial-based CFAR to calculate the noise power wrongly and accordingly a miss-generation of the point cloud. To fundamentally solve the problem, this paper proposes a temporal-based CFAR named ETCM-CFAR. We address multiple issues such as lacking initial noise power and the absence of a closed-form threshold solution to make the proposed algorithm work. Based on ETCM-CFAR, this paper proposes a point cloud generation system named mmPC. mmPC is implemented on three different types of commercial-off-the-shelf mmWave radars and extensive experiments demonstrate that mmPC significantly improves point cloud quality, increasing the number of cloud points by 148.6% compared to the state-of-the-art systems. Two representative sensing applications, i.e., fitness activity recognition and human-pet classification are further employed to demonstrate the effectiveness of mmPC on sensing.
15 June 2026 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
MmWave radar has emerged as a promising technology for human sensing. While large bandwidths and multiple antennas enable high-quality point clouds for sensing applications, low-cost 24 GHz radars are restricted to 250 MHz bandwidth by regulations, leading to limited range resolution. In addition, the limited number of antennas, constrained by cost and device size, results in low angular resolution. Together, these limitations produce sparse point clouds that impede fine-grained human sensing. In this work, we present RaPoint, the first system to produce high-density point clouds from 24 GHz radars under regulatory bandwidth limits. RaPoint introduces a joint super-resolution modeling framework that leverages the MUSIC algorithm to jointly exploit super-resolution range and angle dimensions, together with the Doppler dimension, for distinguishing reflection points. To overcome the high computational complexity problem of the MUSIC algorithm, we convert the eigenvalue decomposition from the noise subspace to the sparse signal subspace, drastically reducing computation. We implement RaPoint on three representative mmWave radars. Extensive experiments demonstrate that RaPoint improves point cloud density by 9.45× and 24.10× over the state-of-the-art research and industrial baselines, respectively, and substantially boosts downstream sensing performance. We believe RaPoint takes a significant step toward fine-grained human sensing with low-cost, bandwidth-limited 24 GHz radars, enabling affordable and ubiquitous radar sensing.
30 September 2026 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Continuous, fine-grained cardiac monitoring during sleep is vital for cardiovascular health. Emerging as a promising alternative to cumbersome wearables, mmWave radar offers a contactless, privacy-preserving modality capable of capturing minute skin vibrations. However, transitioning mmWave radar from labs to real-world bedrooms remains challenging. Our rigorous empirical evaluation of state-of-the-art systems reveals a severe reliability gap: valid Inter-Beat Intervals (IBI) are captured for only 24%-42% of the night within an error threshold of 50 ms. Since clinical HRV analysis requires millisecond-level precision (e.g., RMSSD changes), such coarse and intermittent tracking renders existing methods medically insufficient. We attribute this failure to two fundamental hurdles: (i) instability driven by overwhelming respiratory interference and postural diversity, and (ii) signal entanglement in co-sleeping scenarios where angular separation defies hardware resolution. To bridge this gap, we present DuBCG. First, to tackle instability, we introduce a Head-Facing configuration to capture the Radar Ballistocardiogram (R-BCG). By leveraging the body's longitudinal recoil, this approach achieves orthogonal respiratory suppression and posture-invariant robustness. Second, to resolve entanglement, we propose the Multi-point Scattering Spatial Selectivity Model, theoretically proving that signal separability is achievable beyond physical resolution limits. Extensive real-world benchmarks demonstrate that DuBCG achieves a median IBI error of 8.4 ms—an 8× improvement over existing methods. This precision bridges the gap from existing intermittent monitoring to long-term, clinically comparable continuous HRV assessment.
30 September 2026 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Highly reflective surfaces such as TV, whiteboard, and granite counters are common indoors. When human motion occurs near these surfaces, the transmitted Wi-Fi signal can undergo multiple specular reflections that involve both the moving target and the surrounding reflectors. These interactions give rise to secondary dynamic reflections (SDRs), additional time-varying signal components beyond the primary target reflection. SDRs can be comparable in strength to the desired sensing path, inducing non-negligible interference and significantly degrading Wi-Fi sensing performance. This paper presents SDR-Sense, a novel approach to recover target reflections in presence of strong SDRs. We analyze the spatial characteristics of SDRs and reveal their localized distribution within a sensing area. Two complementary metrics, Curvature Standard Deviation (CSD) and Interference to Sensing Path Loss Ratio (ISPLR), are proposed to detect periods of strong-reflection interference. SDR-Sense further identifies optimal differential intervals and applies CSI differencing to successively recover target reflections during interfered periods, thereby enhancing the sensing signal-to-interference ratio. Implemented on commodity Wi-Fi devices, SDR-Sense is evaluated through two representative sensing applications, namely, human trajectory tracking and gesture recognition, across diverse participants and environments. Experimental results show substantial performance gains over existing methods and demonstrate its potential to benefit a broad range of downstream Wi-Fi sensing tasks.