Cement poles serve as supporting components for transmission lines and are widely used in medium- and low-voltage transmission networks. The main rebar is the primary load-bearing structure of the pole, and the accurate measurement of its diameter and embedment depth is crucial for quality control and safety assessment. However, existing non-destructive testing methods lack the accuracy of quantifying the internal main rebar of cement poles, and the measurement process is complex, cumbersome, and inefficient. To address this issue, this paper proposes a magnetic rotation-based detection method for measuring the diameter and embedment depth of the main rebar within cement poles. A specially designed H-type magnetic excitation structure is proposed, coupled with a detection technique utilizing rotating permanent magnets. The magnetic induction intensity data were acquired at seven distinct rotation angles using sensors, and the collected data were subsequently combined with a CNN-LSTM model to invert the diameter and embedment depth of the main rebar. The experimental results indicate that the method significantly improved the measurement accuracy compared with the condition of fixed magnetic excitation, with reductions in root mean square error (RMSE) of 46.71% and 35.57% for the diameter and embedment depth measurements, respectively. This method provides a robust, efficient, and accurate solution for quantifying the main rebar within cement poles, addressing the challenge associated with the quality assessment and health monitoring of these structures.
During the long-term operation of the DC grounding electrode of the converter station, there are often hazards such as heating and aging of the coke layer, and burning and corrosion at the connection between the feed rod and the cable, resulting in break problems at the connection between the cable and the feed rod. Currently, the operational status monitoring of grounding electrodes primarily relies on daily tracking of well temperature, humidity, and water level characteristics; periodic testing; and on-site excavation. However, the above methods cannot accurately obtain the breakage location information at the connection between the cable and the feed rod. To address these issues, this paper first analyzes the current distribution law in the feeder rod of the DC grounding electrode. Subsequently, it studies the impact of localized fractures in the DC grounding electrode on the surface potential distribution characteristics. Finally, an Operation State Detection Method (OSDM) based on potential distribution is proposed and validated through case studies, demonstrating high measurement accuracy. The results indicate that OSDM can effectively monitor the operational status of DC grounding electrodes, providing a reference for their maintenance and repair.