Biomagnetic field measurement is a promising tool for the investigation of electrical activities in a living body. Room temperature (RT) magnetic sensors with an improved resolution such as magnetoresistance (MR) devices have been recently employed for the detection of weak magnetic fields, which were earlier detected solely using superconducting interference device magnetic sensors. The position, orientation, and sensitivity of each magnetic sensor in a sensor array must be precisely determined for accurate magnetic source analysis. We proposed a calibration method using an array of multiple coils, which is applicable to an RT magnetic sensor array. To demonstrate the validity of the proposed calibration method, we applied it to an MR device-based magnetocardiography (MCG) system equipped with an L-shaped planar sensor array, which was newly developed for the simultaneous observation of both anterior and lateral sides of the body. The deviation of the sensor parameters from the designed values was estimated via calibration. The result of the marker coil localization test indicated that the calibration considerably improved the accuracy of the magnetic source analysis. Finally, we demonstrated a preliminary MCG measurement using the calibrated magnetic sensor array.
10 April 2023 in IEEE Transactions on Instrumentation and Measurement
We proposed a spherical coil array for determining the positions, orientations, and sensitivities of the magnetometers for whole-head magnetoencephalograph (MEG) systems. The coil array comprises 16 concentric and symmetrically oriented circular coils with a diameter of 150 mm, which is larger than those of conventional calibration coil arrays, such as 5 mm or 60 mm. The accuracy of the calibration was expected to improve because the relative mechanical errors in machining and assembly could be reduced when the coil diameter was increased. Moreover, we also proposed a method to estimate the uncertainties in calibration, and it was demonstrated that the sensor parameters of each sensor were successfully obtained with uncertainties using a spherical calibration coil array. Additionally, the accuracy of the calibration was evaluated using a dry-type MEG phantom, and as expected, it was found that the accuracy was improved from that of a conventional calibration coil array composed of an assembly of multiple 3-axis bobbins.
7 December 2021 in IEEE Transactions on Applied Superconductivity
The use of helium recycling systems for magnetoencephalography (MEG) has rapidly expanded in recent years. Placing the cryocooler close to the MEG cryostat is expected to aid in achieving a high helium-recycling efficiency. However, the cryocooler typically introduces a large amount of magnetic interference in the MEG system owing to mechanical vibration, and electric and magnetic noise. In this study, we proposed a mobile reference sensor method using fluxgate magnetometers and vibration meters to reduce the noise originating from the cryocooler. We placed the MEG cryostat, which included superconducting quantum interference device (SQUID)-based MEG sensors and reference magnetometers, and a pulse-tube cryocooler inside a magnetically shielded room. We recorded the vibration and magnetic noise during the operation of the cryocooler using the vibration meters and fluxgate magnetometers placed on the cryocooler and reference SQUID magnetometers as the reference noise data. A noise reduction algorithm named time-shift principal component analysis (TSPCA) was applied to the recorded MEG sensor data by employing the reference noise data. A noise reduction ratio of –39 dB was achieved without temporal and spatial distortion of the MEG signal using an MEG phantom. Thus, we conclude that the mobile reference sensor method with the TSPCA algorithm is an effective technique for reducing the magnetic noise originating from the cryocooler.
1 January 2013 in IEICE Transactions on Electronics
Magnetoencephalography (MEG) is a vital tool for understanding neural dynamics, offering a noninvasive technique for measuring subtle magnetic field variations around the scalp generated by synchronized neuronal activity. Two prominent sensor technologies exist: the well-established superconducting quantum interference device (SQUID) and the more recent optically pumped magnetometer (OPM). Although many studies have compared these technologies using human-subject data in neuroscience and clinical studies, a direct hardware-level comparison using dry phantoms remains unexplored. This study presents a framework for comparing SQUID- with OPM-MEG systems in a controlled environment using a dry phantom that emulates neuronal activity, allowing strict control over physiological artifacts. Data were obtained from SQUID and OPM systems within the same shielded room, ensuring consistent environmental noise control and shielding conditions. Positioning the OPM sensors closer to the signal source resulted in a signal amplitude approximately 3–4 times larger than that detected by the SQUID-MEG system. However, the source localization error of the OPM-MEG system was approximately three times larger than that obtained by the SQUID-MEG system. The cause of the large source localization error was discussed in terms of sensor-to-source distance, sensor count, signal–noise ratio, and the spatial coverage provided by the sensor array of the source signal.