Georgiana Osiceanu

Dr. Georgiana Osiceanu

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
GOGeorgiana Osiceanu
Georgiana Osiceanu
FTFlavia Roxana Toma
Flavia Roxana Toma
RVRoxana Vasiliu
Roxana Vasiliu
SPSorin Daniel Porojan
Sorin Daniel Porojan
LPLiliana Porojan
Liliana Porojan
This study investigates the influence of water immersion on direct composite resins in comparison with subtractive processed composite resins. It evaluates changes in their optical characteristics, surface roughness, solubility, and water sorption. Four CAD/CAM materials (Vita Enamic, Brilliant, Cerasmart, and Tetric) and three direct composite resins (Gradia Direct Anterior A2, Tetric Evo Ceram A2, and Filtek Z550 A2) were examined. Direct composite samples were created using a 3D-printed mold, compressed, and photopolymerized, whereas CAD/CAM samples were sectioned and processed to the same dimensions. Seventy samples (n = 10) were prepared. After dehydration and initial weighing, samples were immersed in distilled water for 30 days, with mass changes recorded at multiple time points. Surface roughness and optical parameters were measured at three stages: post-dehydration, post-immersion, and post-reconditioning. ANOVA, unpaired and paired Student’s t-tests, and Pearson correlation coefficient were used to evaluate the variables. The drawn conclusion was that there were significant differences both between stages and between the materials. The most stable material in terms of water sorption was Vita Enamic. Regarding the optical parameters, Brilliant, Vita, and Cerasmart displayed higher stability, while Tetric CAD, Tetric, Gradia, and Filtek showed increased sensitivity to water immersion and re-desiccation. Gradia exhibited the highest surface roughness, while the CAD-CAM materials demonstrated the greatest stability.

17 July 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
GOGeorgiana Osiceanu
Georgiana Osiceanu
RVRoxana Vasiliu
Roxana Vasiliu
FTFlavia Roxana Toma
Flavia Roxana Toma
RNRadu Marcel Negru
Radu Marcel Negru
NSNicusor-Alin SIRBU
Nicusor-Alin SIRBU
LPLiliana Porojan
Liliana Porojan
The ongoing development of subtractive options for indirect restorations places clinicians in a position that requires adaptation, understanding and choosing of the most suitable option for the long-term survival of the restoration. Mechanical parameters represent important indicators of long-term success. Consequently, this research aimed to assess the impact of water sorption on the mechanical properties of two direct resin composites, Gradia Direct Anterior A2 and Filtek Z550 A2 and three CAD/CAM subtractively manufactured dental resin composites, Vita Enamic, Brilliant and Cerasmart. A total of one hundred specimens (50 control, 50 underwent this protocol: dehydration, immersion in distilled water for 30 days and then re-desiccation), standardized to the dimensions of 14 mm × 4 mm × 1.2 mm were subjected to three-point bending test (based on ISO 4049:2019 and ISO 6872:2015), in order to find out the flexural strength and the elastic modulus of the material at the breaking point. Then, the fractured sample surfaces were fractographical analyzed. Using the two-parameter Weibull approach, the Weibull modulus (m) and the characteristic strength (σ0) were evaluated. In this investigation, the elastic modulus varied from 5.8 (Gradia Control) to 20.31 (Vita Degraded) GPa, with the upper limit close to the values of natural dentin (17.7–29.8 GPa). The values of flexural strength ranged from 174.47 (Brilliant Control) to 79.2 (Gradia Control), subtractively processed materials demonstrating higher flexural strength and elastic modulus values than the direct resin composites, which is related to their high inorganic filler content. All material groups, except for Gradia Control, had a flexural strength more than the 80 MPa minimum value needed to sustain masticatory force. The dehydration and hydration cycles did not have a statistically significant influence on the mechanical properties of the material. The fractographic analysis revealed fracture patterns and features associated with the microstructure, with the PICN category material being particularly notable. Weibull analysis revealed that the direct resin composite materials exhibited higher reliability, lower data scatter and CAD-CAM materials showed greater characteristic strength, with a notably high performance of the nano-hybrid direct resin composite.

10 December 2025 in Materials
Verified
Journal Article
Open access
PDF file
GOGeorgiana Osiceanu
Georgiana Osiceanu
SCSebastian Ciurescu
Sebastian Ciurescu
LPLiliana Porojan
Liliana Porojan
The objective of this study was to evaluate whether any coating material would have a beneficial influence on maintaining color stability and surface roughness and to what extent an uncoated resin composite can keep its original color. The study evaluated three direct composite resins (Gradia Direct Anterior A2, Tetric EvoCeram A2, Filtek Z550 A2) using 30 samples per material (1 mm thick, 14 × 10 × 1 mm). Samples were prepared in 3D-printed molds, light-cured for 40 s, and initially smoothed with abrasive paper (grit 400–2000). The surface treatments applied were as follows: group 1—polished with a brush and Compo + polishing paste, group 2—conditioned with 37% phosphoric acid, ScotchBond adhesive applied, light-cured. All samples were cleaned ultrasonically for 5 min. Initial surface roughness and color were measured with a profilometer and spectrophotometer. Samples were then immersed in distilled water (control at 37 °C), Coca-Cola and red wine (at 10 °C) with surface roughness and color changes measurements taken on days 1, 7, 14 and 90. Immersion media were refreshed weekly. The most notable color changes after immersion in coloring solutions were observed in the groups treated with Coca-Cola and red wine compared with the control group in distilled water. Tetric EvoCeram sealed and Gradia sealed maintained the greatest resistance to perceptible coloration over 90 days, while Filtek Z550 performed the poorest. Tetric EvoCeram sealed maintained the greatest color stability (ΔE < 3.5 at 90 days), whereas Filtek Z550 sealed showed early degradation. Roughness is often decreased by surface sealing. As immersion time rises, unsealed surfaces often become noticeably rougher than sealed ones. This study simulates the oral environment and the exposure of restorative materials to staining agents. As the loss of esthetic properties over time is a continuous problem, the clinical significance of this research lies in demonstrating how a restorative material could resist pigmentation, when in contact with well-known high staining beverages, in order to maintain its esthetic properties and remain suitable for long-term use in the oral cavity. Moreover, the hypothesis that a coating material would protect the resin composite surface and reduce discoloration and surface roughness was tested.

3 April 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
GOGeorgiana Osiceanu
Georgiana Osiceanu
RVRoxana Vasiliu
Roxana Vasiliu
FTFlavia Roxana Toma
Flavia Roxana Toma
MGMihaela Gherban
Mihaela Gherban
LPLiliana Porojan
Liliana Porojan
Background/Objectives: Modern dentistry focuses on the ongoing development of digital alternative technologies and the study of the properties of these innovative materials is deemed essential. Therefore, the objectives of this study were to evaluate the optical and surface characteristics of six computer-aided design/Computer-Aided Manufacturing (CAD-CAM) dental materials, both subtractive and additive, in relation to in vitro degradation. Methods: CAD-CAM dental materials, subtractively processed (Vita Enamic, Cerasmart, Brilliant and Tetric) and additively manufactured (Saremco Crowntec and Voco C&B), were prepared to standard dimensions of 14 × 10 × 1 mm, with baseline measurements taken prior to, and after, the degradation procedures, consisting of immersion in an ADA-recommended staining broth, artificial aging (thermocycling), and the combined effects of staining and in vitro aging. Additionally, two different surface treatments were investigated (polished and glazed). Results: The poorest color stability was observed for Tetric glazed specimens (mean value 25.585) subjected to staining, while the best performance was recorded for Brilliant polished Control (average value of 0.781). The staining procedure produced the most pronounced color changes. Surface treatment did not significantly affect color stability, and surface roughness was not influenced by either the degradation method or the surface treatment (p > 0.05). Atomic Force Microscopy (AFM) evaluation revealed superior performance of the glazed surfaces, characterized by lower nanoroughness values compared with polished surfaces and a smoother surface appearance. Conclusions: The staining potential of staining broth was demonstrated in this study, with the highest values recorded after the staining procedures. In addition, the influence of artificial aging alone and artificial aging combined with staining was investigated, providing relevant results for a better clinical approach. Moreover, surface treatment demonstrated reliability and therefore clinical applicability.

30 July 2026 in Polymers
Verified
Journal Article
Open access
PDF file
RVRoxana Vasiliu
Roxana Vasiliu
GOGeorgiana Osiceanu
Georgiana Osiceanu
FTFlavia Roxana Toma
Flavia Roxana Toma
MGMihaela Gherban
Mihaela Gherban
DUDiana Uțu
Diana Uțu
LPLiliana Porojan
Liliana Porojan
The nanoscale surface topography and microhardness of additive and subtractive dental polymers were evaluated following exposure to environmental challenges. The study examined two 3D-printed resins (Saremco and Voco) and two milled CAD/CAM blocks (Vita Enamic and Tetric). Specimens were allocated to control or experimental groups and subjected to hydrothermal ageing (thermocycling), in vitro mechanical wear, or a combined protocol involving wear followed by thermal ageing. Surface microtopography was analysed both quantitatively and qualitatively using atomic force microscopy (AFM), while structural stability was assessed through surface microhardness testing. Statistical significance was determined using matrix comparisons (p < 0.05). Milled monolithic blocks demonstrated a dense, uniform baseline topography, whereas 3D-printed resins exhibited structural heterogeneity attributed to their layer-by-layer photocuring process. Saremco maintained polymer network stability under thermal stress (p = 0.1878), while Voco was highly susceptible to hydrothermal swelling and early matrix plasticization (p = 0.0084). The combined protocol of wear and thermal ageing resulted in advanced structural breakdown in all groups (p < 0.001). Industrial subtractive blocks exhibited greater resistance to oral environmental stresses. The ceramic framework of Vita Enamic limited polymer domain collapse, whereas Tetric experienced accelerated inter-layer delamination and embrittlement. The combined protocol of wear followed by thermal ageing resulted in significant and uniform degradation of surface microhardness and topographic roughness in all tested groups. Nevertheless, the additively manufactured resins demonstrated substantial structural integrity and exhibited low volumetric wear rates.

4 September 2026 in Polymers
Verified
Journal Article
Open access
PDF file
GOGeorgiana Osiceanu
Georgiana Osiceanu
RVRoxana Vasiliu
Roxana Vasiliu
FTFlavia Roxana Toma
Flavia Roxana Toma
NSNicusor-Alin SIRBU
Nicusor-Alin SIRBU
RFRaluca Faur
Raluca Faur
LPLiliana Porojan
Liliana Porojan
Three-dimensional (3D) printing technology has become more and more popular in restorative dentistry; however, information regarding the mechanical properties of 3D-printed restorative materials remains limited. The aim of this study was to evaluate the behavior under compressive loading until fracture of occlusal veneers fabricated from two types of 3D-printed resin composites, Saremco Print Crowntec A2 and Voco V-Print C&B Temp A2, intended for permanent and temporary clinical restorations, respectively. The study design involved scanning a first upper premolar typodont tooth, previously prepared to receive an occlusal veneer restoration, followed by the computer-aided design of the occlusal veneers and resin dies and 3D printing, resulting in 20 samples. The cemented restorations were subjected to mechanical testing using a fracture-resistance test at a speed of 5 mm/min, applied until failure. The recorded failure forces ranged between 571 and 970 Newton (N), values that are comparable to physiological masticatory forces. The absorbed energy was calculated as the area under the force–displacement curve using the trapezoidal integration method. The mean energy at failure was 0.301 Joule (J) (Voco) and 0.244 Joule (J) (Saremco), with Voco demonstrating greater toughness. In terms of fracture pattern classification, the 3D-printed resin with a lower filler content presented a more catastrophic failure mode compared with the material with a higher filler content. Fractographic analysis revealed characteristic fracture patterns and failure-specific features. Higher predictability and greater fracture strength were observed for the low-filled material, as indicated by the Weibull analysis.