Background: Bending tests offer technical advantages when material testing is performed to determine the modulus of elasticity. In biomechanical studies, beam-like cortical bone specimens subjected to flexural loading are usually characterized by nonuniform cross-sectional properties along the beam axis and a comparatively large spatial variation of the local material properties. Objective: A suitable evaluation method for determining the average modulus of elasticity within the volume of beam-like specimens with nonuniform cross section was to be identified. Methods: A total of 138 samples of human pelvic cortical bone were extracted and tested under flexural loading. Different methods, all based on the linear-elastic flexural theory of beams, were applied to determine the average modulus of elasticity on the basis of measured deformations, and the results were compared. Some of these methods utilized the measured midspan deflection, and others used the elastic curve obtained by digital image correlation. Results: The results showed that it was not appropriate to determine the average modulus of elasticity from only the measured midspan deflection. The consideration of deflections at multiple points along the beam axis is recommended. Conclusions: An evaluation method based on the fitting of the analytically determined elastic curve of the beam with its nonuniform cross-sectional properties to the measured deflections is considered the most appropriate method for determining the average modulus of elasticity of the specimen.
The complexity of the osseo-ligamentous lumbopelvic system has made it difficult to perform both, the overall preparation as well as specimen harvesting and material testing with a reasonable amount of time and personnel. The logistics of such studies present a hurdle for reproducibility. A structured procedure was developed and proved, which allows all necessary steps to be carried out reproducibly and in a reasonable time. This enables the extraction of 26 soft tissue, 33 trabecular and 32 cortical bone specimens from this anatomical region per cadaver. The integrity of the specimens remains maintained while keeping requirements within manageable limits. The practicability of the intended five-day specimen harvesting and testing procedure could be demonstrated on five test and two pre-test sequences. The intended minimization of physical, biological, and chemical external influences on specimens could be achieved. All protocols, instructions and models of preparation and storage devices are included in the supporting information. The high grade of applicability and reproducibility will lead to better comparability between different biomechanical investigations. This procedure proven on the human pelvis is transferable to other anatomical regions.
This study investigates methodological variability across various expert laboratories worldwide, with regards to characterizing the mechanical properties of biological tissues. Two testing rounds were conducted on the specific use case of uniaxial tensile testing of porcine aorta. In the first round, 24 labs were invited to apply their established methods to assess inter-laboratory variability. This revealed significant methodological diversity and associated variability in the stress-stretch results, underscoring the necessity for a standardized approach. In the second round, a consensus protocol was collaboratively developed and adopted by 19 labs in an attempt to minimize variability. This involved standardized sample preparation and uniformity in testing protocol, including the use of a common cutting and thickness measurement tool. Despite protocol harmonization, significant variability persisted across labs, which could not be solely attributed to inherent biological differences in tissue samples. These results illustrate the challenges in unifying testing methods across different research settings, underlining the necessity for further refinement of testing practices. Enhancing consistency in biomechanical experiments is pivotal when comparing results across studies, as well as when using the resulting material properties for in silico simulations in medical research.
The osseo-ligamentous lumbopelvic complex is essential for musculoskeletal load transfer, yet location-specific material data and standardized test protocols remain scarce, which is a hindrance for comparability. Based on 91 specimen locations per cadaver (five cadavers, average age: 77.3 years), we developed detailed methods for specimen preparation and mechanical testing (bending, tensile, and compression) with defined boundary conditions. Multiple measurements were taken to assess repeatability. The proposed methods allow us to identify location-specific properties of the lumbopelvic system for the first time. Cortical bone exhibited an elastic modulus of 1750 MPa and an ultimate strength of 28.2 MPa, while those of trabecular bone were 32.7 MPa and 1.26 MPa, and soft tissues revealed values of 148 MPa and 14.3 MPa for fascial tissue and 103 MPa with 10.7 MPa for ligamentous tissue, respectively. The quantified properties for cortical and trabecular bone and soft tissues not only enhance the comparability of material properties but also support more accurate numerical simulations and implant design. Furthermore, the ease of implementation and standardization of these methods enable their widespread application, as well as the accumulation of a broad database and the setting of benchmarks for future investigations.
2 February 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Various studies have shown that the water content affects the elastic behavior of cortical bone. However, there is disagreement regarding the reversibility of the elastic behavior with rewetting. This study investigates this issue using an intrinsic approach, i.e., moisture manipulation and material testing were always carried out on the same specimen. The test results were then evaluated separately for each of several specimens. In total, 24 specimens of human cortical bone from the ischiopubic ramus were examined. The water content was varied in 11 steps, and the corresponding elastic moduli were determined using three-point bending tests within the elastic range. Moisture adjustment was achieved mainly using desiccators, accelerated by forced convection. Reference samples stored in the same manner were evaluated microscopically. The experiments confirmed the known correlation between water content reduction and stiffness increase of cortical bone. Complete drying increased the elastic modulus by about 83 %. By rewetting, the stiffness was significantly reduced again, though not only to the initial state, but even about 24 % below this. Thus, an irreversible alteration of the elastic behavior was observed. Decay of the reference samples was not observed. Therefore, decay is not the main reason for the significant loss of stiffness. In terms of the storage conditions for cortical bone specimens, an environment with 100 % relative humidity yielded the best match with the initial state. This storage method can therefore be recommended for biomechanical specimens used to determine in-vivo-like material parameters.
The osseo-ligamentous lumbopelvic complex is a crucial component of the human musculoskeletal system and has been increasingly the focus of medical research and treatment planning. Numerical simulations can play a key role in better understanding the load-carrying behavior of this system, but material data in this arena remain rare. In addition, the literature lacks standardized and reproducible methods for determining biomechanical material parameters. To address these shortcomings, we obtained bone and soft tissue samples from three female and two male cadavers (average age: 77.3 years) for testing and evaluation. The elastic modulus of cortical bone averaged at 1750 MPa with a mean ultimate strength of 28.2 MPa. Whereas for trabecular bone the evaluation yields to 32.7 MPa and 1.26 MPa. Furthermore, the soft tissue specimens exhibited a mean elastic modulus of 148 MPa and an ultimate strength of 14.3 MPa for fascial tissue, in contrast to ligamentous tissue with 103 MPa and 10.7 MPa. Knowledge of these material parameters of the human pelvis, which differ from those of long bones, could, in combination with the revealed dependence on harvesting location and density, lead to more precise mechanical simulations. Such simulations might in turn promote the development of better suited implants. Together with a previous publication dealing with sample preparation, this work is intended to contribute to the standardization of mechanical testing of human tissue. Easy-to-conduct bending tests as well as direct tension and compression tests are recommended, and the proposed mechanical boundary conditions are explained and documented. These technical recommendations allow for better comparability and reproducibility in future biomechanical studies. This protocol, developed for the human pelvis, could easily be transferred to other anatomical regions.