Sascha Kurz

Mr. Sascha Kurz

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2025 in Journal of Biomechanics
Verified
Journal Article
Closed access
NFNele Famaey
Nele Famaey
HFHeleen Fehervary
Heleen Fehervary
YLYoann Lafon
Yoann Lafon
AAAli Akyildiz
Ali Akyildiz
SDSilke Dreesen
Silke Dreesen
LGLiesbet Geris
Liesbet Geris

21 January 2024 in Materials & Design
Verified
Journal Article
Open access
LILena-Christin Ingwersen
Lena-Christin Ingwersen
MAMatthias Ahlhelm
Matthias Ahlhelm
ESEric Schwarzer-Fischer
Eric Schwarzer-Fischer
SKSascha Kurz
Sascha Kurz
ERElena Riemer
Elena Riemer
AJAnika Jonitz-Heincke
Anika Jonitz-Heincke

19 July 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
HSHanno Steinke
Hanno Steinke
SKSascha Kurz
Sascha Kurz
BFBenjamin Fischer
Benjamin Fischer
SSSandra Schuberth
Sandra Schuberth
CHConstance Hobusch
Constance Hobusch
CHChristoph-Eckhard Heyde
Christoph-Eckhard Heyde

3 August 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SKSascha Kurz
Sascha Kurz
MGMarc Gebhardt
Marc Gebhardt
FGFanny Grundmann
Fanny Grundmann
CHChristoph-Eckhard Heyde
Christoph-Eckhard Heyde
HSHanno Steinke
Hanno Steinke
The complexity of the osseo-ligamentous lumbopelvic system has made it difficult to perform both, the overall preparation as well as specimen harvesting and material testing with a reasonable amount of time and personnel. The logistics of such studies present a hurdle for reproducibility. A structured procedure was developed and proved, which allows all necessary steps to be carried out reproducibly and in a reasonable time. This enables the extraction of 26 soft tissue, 33 trabecular and 32 cortical bone specimens from this anatomical region per cadaver. The integrity of the specimens remains maintained while keeping requirements within manageable limits. The practicability of the intended five-day specimen harvesting and testing procedure could be demonstrated on five test and two pre-test sequences. The intended minimization of physical, biological, and chemical external influences on specimens could be achieved. All protocols, instructions and models of preparation and storage devices are included in the supporting information. The high grade of applicability and reproducibility will lead to better comparability between different biomechanical investigations. This procedure proven on the human pelvis is transferable to other anatomical regions.

18 July 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SSStefan Schleifenbaum
Stefan Schleifenbaum
FMFlorian Metzner
Florian Metzner
JSJanine Schultze
Janine Schultze
SKSascha Kurz
Sascha Kurz
CHChristoph - Eckhard Heyde
Christoph - Eckhard Heyde
PPPhilipp Pieroh
Philipp Pieroh
Pedicle screw fixation is a common spinal surgery technique, but concerns remain about stability when screws are malpositioned. Traditional in vitro pull-out tests assess anchorage but lack physiological accuracy. This study examined the stability of correctly placed and intentionally malpositioned pedicle screws on forty vertebrae from five cadavers. Optimal screw paths were planned via CT scans and applied using 3D-printed guides. Four malposition types—medial, lateral, superior, and superior-lateral—were created by shifting the original trajectory. A custom setup applied three consecutive cycles of tensile and compressive load from 50 N to 200 N. Screw inclination under load was measured with a 3D optical system. The results showed increasing screw inclination with higher forces, reaching about 1° at 50 N and 2° at 100 N, similar in both load directions. Significant differences in inclination were only found at 100 N tensile load, where malpositioned screws showed a lower inclination. Overall, malpositioning had no major effect on screw loosening. These findings suggest that minor deviations in screw placement do not significantly compromise mechanical stability. Clinically, the main concern with malpositioning lies in the potential for injury to nearby structures rather than reduced screw fixation strength.

11 August 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
MGMarc Gebhardt
Marc Gebhardt
SKSascha Kurz
Sascha Kurz
FGFanny Grundmann
Fanny Grundmann
TKThomas Klink
Thomas Klink
VSVolker Slowik
Volker Slowik
HSHanno Steinke
Hanno Steinke
The osseo-ligamentous lumbopelvic complex is essential for musculoskeletal load transfer, yet location-specific material data and standardized test protocols remain scarce, which is a hindrance for comparability. Based on 91 specimen locations per cadaver (five cadavers, average age: 77.3 years), we developed detailed methods for specimen preparation and mechanical testing (bending, tensile, and compression) with defined boundary conditions. Multiple measurements were taken to assess repeatability. The proposed methods allow us to identify location-specific properties of the lumbopelvic system for the first time. Cortical bone exhibited an elastic modulus of 1750 MPa and an ultimate strength of 28.2 MPa, while those of trabecular bone were 32.7 MPa and 1.26 MPa, and soft tissues revealed values of 148 MPa and 14.3 MPa for fascial tissue and 103 MPa with 10.7 MPa for ligamentous tissue, respectively. The quantified properties for cortical and trabecular bone and soft tissues not only enhance the comparability of material properties but also support more accurate numerical simulations and implant design. Furthermore, the ease of implementation and standardization of these methods enable their widespread application, as well as the accumulation of a broad database and the setting of benchmarks for future investigations.