Igor Klementowski

Mr. Igor Klementowski

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
EJElżbieta Janowska-Renkas
Elżbieta Janowska-Renkas
AKAnna Król
Anna Król
IKIgor Klementowski
Igor Klementowski
MSMichał Sokolski
Michał Sokolski
In this work, to enhance the compressive strength and evaluate the fire resistance of hemp concrete, we incorporated mineral additives such as FBC fly ash and metakaolin. This paper investigates the thermal conductivity, compressive strength, flammability, and fire resistance of hempcrete and the influence of mineral additives in the form of fly ash from fluidized bed combustion (FBC) and metakaolin on these properties. A fly ash content of 20% by weight of the binder resulted in an increase of 26% in compressive strength and about 6% in thermal conductivity compared to hemp concrete without mineral additives. The use of metakaolin in the amount of 15% by weight of the binder resulted in a 21% increase in compressive strength values with an increase in the thermal conductivity coefficient of only 0.5%. Flammability tests by direct application of a gas torch flame to the specimen surface proved the lack of flammability and spontaneous fire extinguishing ability of hempcrete. In turn, fire resistance tests showed much higher resistance to high temperatures for hempcrete modified with metakaolin, where the recorded mass loss during a 15 min test at 500 °C was ca. 58% less than in hempcrete without mineral additives, and when FBC fly ash was used, the mass loss was ca. 37% less. The obtained results are satisfactory in terms of the physico-mechanical properties of hempcrete. They also enable the replacement of traditional construction materials with waste-derived materials from other sectors of the economy, which, in the long term, will contribute to the development of green construction and support the principles of the circular economy.

26 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
EJElżbieta Janowska-Renkas
Elżbieta Janowska-Renkas
DFDariusz FABIANOWSKI
Dariusz FABIANOWSKI
IKIgor Klementowski
Igor Klementowski
Kinga BorekKinga Borek
Kinga Borek
AKAdam Koniuszy
Adam Koniuszy
Grzegorz WałowskiGrzegorz Wałowski
Grzegorz Wałowski
The paper presents the results of experimental studies aimed at assessing thermal conductivity, compressive strength, water absorption and capillary action of samples in the form of ordinary concrete (reference sample—B1) and lightweight concrete with the addition of a biocomponent (C100) in the range of 3–31.2% porosity with varied morphology. Gas permeability studies were conducted for porous materials with an anisotropic structure. The measurement results indicate a significant effect of the type of material on thermal conductivity for B1, which is 3.05 W·(m·K)−1 and C100 equal to 0.09 W·(m·K)−1. On the other hand, the highest water absorption is demonstrated by C100, which is 99%, and the lowest by B1 equal to 2%. Tests were conducted for different gas permeability conditions using oxygen (O2), nitrogen (N2) and carbon dioxide (CO2). The basis for assessing gas permeability through porous beds is the gas flow resulting from the overpressure forcing this flow. The highest gas permeability coefficient at a flow resistance of 6 kPa for B1 was 2.7·10−7 m2, and for C100, 2.1·10−7 m2 at CO2 flow. The following issues were identified: scientific, identifying the lack of research on gas permeability testing for anisotropic concrete structures; application, identifying reports of premature failure of concrete structures in livestock buildings due to the effects of toxic substances. The novelty in the article is the indication of the gas permeability model and the performance of a comparative analysis (multi-criteria analysis) based on diagnostic features. In the hierarchical decision-making structure, gas permeability was used as one of the evaluation criteria, which can be assessed as a stimulant or destimulant depending on the climatic zone. The permeability of gas media is one of the features that allow for assessing the suitability of materials, among others, for small-sized prefabricated wall systems—the durability of both the element itself and any reinforcing inserts depends on permeability. The aim of this article was to compare the physical and functional properties of materials, such as thermal conductivity, water absorption, capillarity and gas permeability, in relation to the material composition. The research was of an application and engineering nature, focusing on macroscale functional parameters that are important from the point of view of the practical application of the tested building composites. The scientific problem is to indicate the lack of scientific research on the study of gas permeability in anisotropic concrete structures in livestock building conditions. The engineering use of hempcrete indicates its usefulness in various structural elements of livestock buildings.

17 April 2024 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
SJSławomira Janiak
Sławomira Janiak
DMDaria Mazurek-Rudnicka
Daria Mazurek-Rudnicka
DHDariusz Heim
Dariusz Heim
IKIgor Klementowski
Igor Klementowski
The method of estimating the uncertainty for measurement of thermal conductivity (λ) based on conducted experimental investigations was presented in this article. Originally designed and developed the measuring system for determining of thermal conductivity of solid bodies using hot wire method was applied. Due to low costs, high accuracy and short time of measurement, it is a common dynamic technique, effectively used in a transitional states. This method includes measurement of temperature rise from linear source of heat („hot wire”) placed in a tested material. The experimental value of the thermal conductivity of the tested composite (gypsum with paraffin and polymer) and values of relative components of standard uncertainties of this parameter were determined. A satisfactory, low value of complex relative extended uncertainty of thermal conductivity U(λ)/λ was obtained.