Manipulator robots hold significant importance for the development of intelligent manufacturing and industrial transformation. Manufacturers and users are increasingly focusing on fault diagnosis for manipulator robots. The voltage, current, speed, torque, and vibration signals of manipulator robots are often used to explore the fault characteristics from a frequency perspective, and temperature and sound are also used to represent the fault information of manipulator robots from different perspectives. Technically, manipulator robot fault diagnosis involving human intervention is gradually being replaced by new technologies, such as expert experience, artificial intelligence, and digital twin methods. Previous reviews have tended to focus on a single type of fault, such as analysis of reducers or joint bearings, which has led to a lack of comprehensive summary of various methods for manipulator robot fault diagnosis. Considering the needs of future research, a review of different fault types and diagnostic methods of manipulator robots provides readers with a clearer reading experience and reveals potential challenges and opportunities. Such a review helps new researchers entering the field avoid duplicating past work and provides a comprehensive overview, guiding and encouraging readers to commit to enhancing the effectiveness and practicality of manipulator robot fault diagnosis technologies.
Wearable electrochemical sensors have attracted tremendous attention and have been experiencing rapid growth in recent years. Sweat, one of the most suitable biological fluids for non-invasive monitoring, contains various chemical elements relating abundant information about human health conditions. In this work, a new type of non-invasive and highly stretchable potentiometric sweat sensor was developed based on all-solid-state ion-selective electrode (ISE) coupled with poly(dimethylsiloxane; PDMS) and polyurethane (PU). This highly stretchable composite of PDMS-PU allows the sensor to be robust, with the PDMS providing a flexible backbone and the PU enhancing the adhesion between the electrodes and the substrate. In addition, graphene–carbon nanotube (CNT) network 3D nanomaterials were introduced to modify the ion selective membrane (ISM) in order to increase the charge transfer activity of the ISEs, which also could minimize the formation of water layers on the electrode surface, as such nanomaterials are highly hydrophobic. As a result, the sensor demonstrated a wide detection range of NH4+ from 10−6 M to 10−1 M with high stability and sensitivity—showing a high sensitivity of 59.6 ± 1.5 mV/log [NH4+] and an LOD lower than 10−6 M. Under a strain of 40%, the sensor still showed a sensitivity of 42.7 ± 3.1 mV/log [NH4+]. The proposed highly stretchable and robust electrochemical sweat sensor provides a new choice for wearable-device-based personal daily healthcare management beyond hospital-centric healthcare monitoring.
Power metal-oxide-semiconductor field-effect transistors (MOSFETs) provide numerous advantages and are widely utilized in various power circuits. The junction temperature plays a critical role in determining the reliability, performance, and operational lifetime of power MOSFETs. Therefore, accurate monitoring of the junction temperature of power MOSFETs is essential to ensure the safe operation of power circuit systems. In bridge or motor drive circuits, MOSFETs often operate in a freewheeling state via the body diode, where the freewheeling current is typically variable. The proposed method for junction temperature measurement utilizes the body diode and is designed to accommodate varying forward currents. It also accounts for the temperature-dependent ideality factor to improve measurement accuracy. By integrating the forward voltage and forward current of the body diode, this approach reduces the required sampling frequency. To validate the method’s effectiveness, three representative types of power MOSFETs, a Si MOSFET (IRF520), a SiC MOSFET (C2M0080120D), and an aerospace-grade radiation-hardened MOSFET (RSCS25045T1RH), were used to measure junction temperatures before and after irradiation. Following ideality factor correction, the maximum absolute error compared to reference measurements from thermocouples and a thermal imager remained within 2 K across the temperature range of 300 K to 420 K. Experimental results confirm the feasibility of the proposed method.
To overcome the problem of insufficient adaptability to the motion environment of lower limb exoskeleton robots, this paper introduces computer vision technology into the motion control of lower limb exoskeleton robots and studies an obstacle-crossing-motion method based on detecting obstacle feature information. Considering the feature information of different obstacles and the distance between obstacles and robots, a trajectory planning method based on direct point matching was used to generate offline adjusted gait trajectory libraries and obstacle-crossing gait trajectory libraries. A lower limb exoskeleton robot obstacle-crossing motion decision-making algorithm based on obstacle feature information is proposed by combining gait constraints and motion constraints, enabling it to select appropriate motion trajectories in the trajectory library. The proposed obstacle-crossing-motion method was validated at three distances between the obstacle and the robot and with the feature information of four obstacles. The experimental results show that the proposed method can select appropriate trajectories from the trajectory library based on the detected obstacle feature information and can safely complete obstacle-crossing motions.
Predominant fault diagnosis in industrial robots depends on dedicated vibration or acoustics sensors. However, their practical deployment is often limited by installation constraints, susceptibility to environmental noise, and cost considerations. Applying Energy-Based Maintenance (EBM) principles to achieve enhanced fault diagnosis under practical industrial conditions, we propose a hybrid deep learning framework, the Multi-head Graph Attention Network (MGAT) with Multi-scale CNNBiLSTM Fusion (MGAT-MCNNBiLSTM) for industrial robots. This approach obviates the need for additional dedicated sensors, effectively mitigating associated deployment complexities. The framework embodies four core innovations: (1) Based on the EBM paradigm, motor current is established as the most effective and practical choice for enabling cost-efficient and scalable industrial robot fault diagnosis. A corresponding dataset of motor current has been acquired from industrial robots operating under diverse fault scenarios. (2) An integrated MGAT-MCNNBiLSTM architecture that synergistically models multiscale local features and complex dynamics through its MCNNBiLSTM module while capturing nonlinear interdependencies via MGAT. This comprehensive feature representation enables robust and highly accurate fault detection. (3) The study found that the application of spectral preprocessing techniques yields a marked and statistically significant enhancement in diagnostic performance. A comprehensive and systematic analysis was undertaken to uncover the underlying reasons for this observed performance improvement. (4) To emulate challenging industrial settings and cost-sensitive implementations, noise signal injection was employed to evaluate model robustness in high-electromagnetic-interference environments and low-cost, low-resolution ADC implementations. Experimental validation on real-world industrial robot datasets demonstrates that MGAT-MCNNBiLSTM achieves a superior diagnostic accuracy of 90.7560%. This performance marks a significant absolute improvement of 1.51–8.55% over competing models, including LCNNBiLSTM, SCNNBiLSTM, MCCBiLSTM, GAT, and MGAT. Under challenging noise and low-resolution conditions, the proposed model consistently outperforms CNNBiLSTM variants, GAT, and MGAT with an improvement of 1.37–10.26% and enhanced industrial utility and deployment potential.