Jing-Yuan Lin

Dr. Jing-Yuan Lin

Department of Electronic Engineering, National Taiwan University of Science and Technology, Da'an Dist., Taipei City 106335, Taiwan

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2022 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
JLJing-Yuan Lin
Jing-Yuan Lin
HYHsuan-Yu Yueh
Hsuan-Yu Yueh
LYLin Yi-Feng
Lin Yi-Feng
LPLiu pin-hsien
Liu pin-hsien
The LLC resonant converter has been widely used in the power supply industry, such as server power, TV power, and adapter, because this converter can realize the zero-voltage switching (ZVS) at the power MOSFETs of the primary side. Thus, the switch losses can be decreased, and the conversion efficiency can also be improved. The electric vehicle (EV) charger has been recently widely used in research and development. However, designing LLC resonant converters for the wide battery voltage range is difficult because this converter is usually utilized in pulse frequency modulation (PFM) to regulate the output voltage. This converter will also be limited on the low operating frequency range for the high conversion efficiency due to the switching frequency. By contrast, the phase-shift modulation (PSM) control for the wide output voltage range has been used at LLC resonant converters. However, the ZVS will be lost due to the lagging leg of the LLC resonant converter when the phase-shift angle is remarkably excessive. The burst-mode control has also been proposed for the converter to regulate the output voltage and maintain high conversion efficiency at light-load conditions. Therefore, this paper utilized the combination of PFM, PSM and burst-mode control for the LLC resonant converter operating at the wide output voltage range for EV charge applications. Furthermore, this paper proposed a synchronous rectification advance on-time control for PFM control, which can help address the ZVS at the lagging leg when the phase-shift angle is excessive. Detailed analysis and design of this control method are also described. The performance evaluation of the proposed LLC resonant converter with hybrid control was finally realized under the following conditions: 3.75 kW, DC input voltage of 400 VDC, DC output voltage of 75–475 VDC and maximum conversion efficiency around 97%.

28 November 2018 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
YHYi-Chieh Hsu
Yi-Chieh Hsu
CTChung-Yi Ting
Chung-Yi Ting
LHLi-Sheng Hsu
Li-Sheng Hsu
JLJing-Yuan Lin
Jing-Yuan Lin
CCCharlie Chung-Ping Chen
Charlie Chung-Ping Chen

7 May 2019 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
CTChung-Yi Ting
Chung-Yi Ting
JLJing-Yuan Lin
Jing-Yuan Lin
CCCharlie Chung-Ping Chen
Charlie Chung-Ping Chen
This paper proposes a buck converter with adaptive constant on time (ACOT) control including transient-enhanced technique for fast dynamic voltage scaling (DVS) and load-transient response in RF Applications. The proposed ACOT control achieves high performance in DVS tracking response to shorten up-tracking time and down-tracking time. Moreover, the high bandwidth transient-enhanced technique in ACOT control improves load-transient response suffering from low bandwidth compensation loop. In addition, the proposed buck converter operates at 2.5MHz for high power density and 90.1% peak efficiency. This work is implemented by TSMC 0.18μm 1P6M CMOS technology with a chip area 1.81 mm2. Measurement results achieve that the output voltage have both 0.6μs and 0.6μs recovery time in 600mA step-up load and 600mA step-down load, respectively. For 0.6V step, the output voltage have both 2μs in up-tracking time and down-tracking time.

17 April 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Dung Anh NguyenDung Anh Nguyen
Dung Anh Nguyen
HUANG-JEN CHIUHUANG-JEN CHIU
HUANG-JEN CHIU
JLJing-Yuan Lin
Jing-Yuan Lin
YHYao-Ching Hsieh
Yao-Ching Hsieh
HCHui-Ting Chen
Hui-Ting Chen
BZBo-Xiang Zeng
Bo-Xiang Zeng
In this study, a novel modulation of an isolated three-phase bidirectional dc-dc converter is proposed for the high-voltage input power supply to low-voltage output energy storage systems. The wye-delta connection of the transformers is employed to reduce the voltage stress at the high side and the current stress at the low side of the transformers. Frequency control allows the output voltage regulation, and a phase-shift algorithm with a resonant tank is proposed following with the switching frequency to reduce the frequency range with the specific power. Furthermore, the zero-voltage-switching condition for all mosfets in the entire power range, which is the major restriction of a single-phase converter, is also discussed in this paper. The three-phase wye-delta converter significantly reduces the ripple of inductor current compared with that of a single-phase converter. A 2 kW prototype converter was built and successfully tested to verify the capability of such control modulation.

21 November 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LPLiu Pang-Jung
Liu Pang-Jung
WCWei-Yi Cheng
Wei-Yi Cheng
LCLin-Hao Chien
Lin-Hao Chien
JLJing-Yuan Lin
Jing-Yuan Lin
This article proposes a configurable supply mechanism in the power stage to simultaneously improve the load transient response and power conversion efficiency. The power stage, comprising a dc–dc converter and an auxiliary power circuit (APC), can be organized depending on the variable load conditions. During step-load changes, the APC can provide an additional charging or discharging current to the output capacitance of the dc–dc converter to compensate for any differences between the load current and inductor current. Meanwhile, two auxiliary transient transistors are employed to immediately adjust the output level of the error amplifier because the peak current-mode control is used in the dc–dc converter. Thus, the recovery time and output transient ripple are enhanced significantly. At the steady state, the APC is inactivated; thus, the conversion efficiency of the dc–dc converter does not degenerate. Above medium loads, only the dc–dc converter is activated to deliver adequate power with high efficiency. At light loads, the APC acts as a linear regulator to take over the energy delivery scheme because power consumption is reduced effectively while the output voltage is kept. Therefore, the hybrid operation can guarantee improvements in load transient response and power conversion efficiency at light loads. The proposed converter was fabricated with 0.35- μ m CMOS technology. The experimental results showed that the recovery times for 450-mA step-down and step-up loads are 1.6 and 2.0 μs, respectively. Comparing to when the transient mode is disabled, the recovery time of the output voltage is improved by over ten times when the transient mode is enabled. Further, the efficiency improvements with the proposed method at load current of 20 mA under the output voltages of 2.5 V and 1.8 V are 13.8% and 4.9%, respectively.

9 May 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JLJing-Yuan Lin
Jing-Yuan Lin
LPLiu pin-hsien
Liu pin-hsien
HYHsuan-Yu Yueh
Hsuan-Yu Yueh
LYLin Yi-Feng
Lin Yi-Feng
The LLC converter has been widely used in the power supply industry for its high conversion efficiency. When the output load is low, the LLC resonant converter will substantially increase the operating frequency, thereby reducing the conversion efficiency and exceeding the limited operating frequency of the specification. Thus, burst-mode control is applied to increase the ability of regulation at light-load conditions. Even so, the switching period of power-switches still occurs at a high switching frequency. Burst-mode control will also result in an extremely low-frequency output voltage ripple. In this study, a valley switching control (VSC) for the LLC resonant converter at light-load conditions is proposed. The VSC control strategy maintains the output voltage by modulating the pulse-width signals of drivers, and achieves valley switching by modulating the switching frequency. Thus, the VSC strategy can reduces the operating frequency compared with the frequency modulation strategy. Compared with burst-mode operations, the proposed VSC effectively reduces the switching loss and has the advantages of the high-frequency output voltage ripple. The VSC increases the efficiency and the power quality of the converter. Detailed analysis and design of the proposed method are described. Experimental results are recorded for a prototype converter with a DC input voltage of 400-VDC, an output voltage of 48-VDC, and an output current of 12.5-A.