Omar Warani Aziz

Dr. Omar Warani Aziz


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2025 in Infrastructures
Verified
Journal Article
Open access
PDF file
SHSWAR IMAD HASIB
SWAR IMAD HASIB
ALAssim Lateef
Assim Lateef
OAOmar Warani Aziz
Omar Warani Aziz
The main objective of this research is to investigate the impact of the tendon profile layout on the shear strength of unbonded post-tensioned prestressed concrete bridge I-girders. This study involves an experimental investigation where ten unbonded post-tensioned bridge girders are cast and subjected to four-point loads. The focus of the investigation is on the effect of different tendon profile layouts, including trapezoidal, parabolic, and harped shapes. The experimental results reveal that the shear behavior of the specimens progresses through three distinct stages: the elastic stage, the elastic–plastic stage, and the plastic stage, with all specimens ultimately failing due to shear. The results show that tendon profiles with higher eccentricity at the end of the beams (80 mm above the neutral axis) had the highest ultimate load capacity for each tendon profile shape, coupled with the largest deflection. Conversely, profiles with lower eccentricity (80 mm below the neutral axis) demonstrated the lower ultimate load capacity for each tendon profile shape and minimal deflection. Among the various tendon profile layouts that were tested, the specimen with the harped tendon profile (GF-1 HA) showed the highest ultimate load capacity, with an increasing rate of 17.52% in ultimate load and a 45.55% increase in ultimate deflection compared to the control beam (GF-1 ST) with a straight tendon profile. On the other hand, the harped tendon profile specimen (GF-1 HA) exhibited the lowest deflection among the various tendon profile shapes with an increasing rate of 5.7% in ultimate load deflection in comparison with the control beam (GF-1 ST) with a straight tendon profile. These improvements in stiffness, load capacity, and deflection are attributed to enhanced resistance, particularly at the supports. Consequently, the optimized tendon layouts offer an increase in the overall structural efficiency, leading to potential cost savings in bridge girder production.

7 November 2019 in Polytechnic Journal
Verified
Journal Article
Open access
PDF file
GWGhassan M. Werdina
Ghassan M. Werdina
OAOmar Warani Aziz
Omar Warani Aziz
Post-tensioning tendons in segmental box girder bridges are usually anchored in very massive diaphragms. This paper presents an analytical investigation of the anchorage zone stresses for an interior pier diaphragm and a rectangular block model (model of diaphragm anchorage zone). The failure load and load-displacement relation for the two cases were compared, a typical diaphragm for a segmental box girder bridge with external prestressing tendons and rectangular block model were analyzed by finite element program (ABAQUS). The anchorage devices were subjected to a prestressing design load which was based on the ultimate strength of the tendons. The magnitude and distribution of stresses were plotted through different paths for both the diaphragm and the block model; also the contours of stress distribution for the diaphragm and block model were compared. The results showed that the stresses and failure load for the diaphragm and rectangular block model were very close.

25 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SHSWAR IMAD HASIB
SWAR IMAD HASIB
ALAssim Lateef
Assim Lateef
OAOmar Warani Aziz
Omar Warani Aziz
The main objective of this research is to evaluate the optimal design of the tendon profile layout and to examine the effect of the tendon profile layout on the flexural strength of unbounded post-tensioned prestressed concrete bridge I-girders. In this study, the experimental investigation involved casting and testing ten unbounded post-tensioned bridge girders under a four point loads. The main variable studied was the tendon profile layout. The experimental results showed that the flexural behavior of tested specimens is divided into three stages: elastic stage, elastic-plastic stage and plastic stage and all specimens exhibit flexural failure. It can be concluded that for each tendon profiles layout (trapezoidal, parabolic, harped), the tendon profiles with eccentricity at end of beam (ee)=0, had maximum ultimate load capacity. It also can be concluded that specimen GF-9 HA (Harped Tendon Profile with ee = 0 mm) had maximum ultimate load capacity from all other specimens. These enhancement in specimens stiffness, ultimate loads capacities and deflections because of increasing resisting capacity , reducing stresses specially at support, reducing deflection, increasing resisting bending moment which lead to reducing the production cost of girder.

15 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SHSWAR IMAD HASIB
SWAR IMAD HASIB
ALAssim Lateef
Assim Lateef
OAOmar Warani Aziz
Omar Warani Aziz
The primary objective of this research is to investigate the impact of tendon profile layout on the shear strength of unbonded, post-tensioned prestressed concrete bridge I-girders. This study involves an experimental investigation where ten un-bonded, post-tensioned bridge girders are cast and subjected to four-point loads. The focus of the investigation is on the effect of different tendon profile layouts, including trapezoidal, parabolic, and harped shapes. The experimental results reveal that the shear behavior of the specimens progresses through three distinct stages: the elastic stage, the elastic–plastic stage, and the plastic stage, with all specimens ultimately failing due to shear. The findings show that tendon profiles with an eccentricity at the end of the beam = -80mm (80 mm above the neutral axis) exhibited the highest ultimate load capacity, coupled with the largest deflection. Conversely, profiles with an eccentricity of = 80mm (80 mm below the neutral axis) demonstrated the lowest load capacity and minimal deflection. Among the various configurations tested, the specimen with the harped tendon profile (GF-1 HA) showed the highest ultimate load capacity. On the other hand, the trapezoidal tendon profile specimen (GF-2 TR) exhibited the lowest deflection. These improvements in stiffness, load capacity, and deflection are attributed to enhanced resistance, particularly at the supports. Consequently, the optimized tendon layouts offer a reduction in deflection and an increase in the overall structural efficiency, leading to potential cost savings in bridge girder production.

20 April 2026 in Buildings
Verified
Journal Article
Open access
PDF file
Karukh Hassan M.KarimKarukh Hassan M.Karim
Karukh Hassan M.Karim
OAOmar Warani Aziz
Omar Warani Aziz
NANoori Sadeq Ali
Noori Sadeq Ali
Building Information Modelling (BIM) has emerged as a transformative approach for improving efficiency, coordination, and sustainability in the construction industry; however, its adoption in developing regions remains limited. In the Kurdistan Region of Iraq (KRG), BIM implementation—particularly within the residential construction sector—remains at an early stage and lacks comprehensive empirical investigation. This study aims to assess stakeholders’ perspectives on current BIM practices, identify key adoption barriers, and develop a context-specific strategic framework to support BIM implementation. A mixed-method research design was employed, incorporating literature review, expert validation through semi-structured interviews, and a structured questionnaire survey. A total of 319 valid responses were analyzed using descriptive statistics, Relative Importance Index (RII), Cronbach’s alpha for reliability, Spearman’s rank correlation, independent samples t-tests, and one-way ANOVA. In addition to ranking barriers, an inter-barrier correlation analysis was conducted to examine the relationships, clustering patterns, and hierarchical structure of BIM adoption challenges. The results indicate that while BIM awareness is moderately established among stakeholders, its practical application remains limited, particularly beyond the design phase. The most critical barriers include lack of training and expertise, absence of regulatory frameworks and standards, insufficient government support, and financial constraints. The correlation analysis reveals that these barriers are interdependent, with policy and institutional deficiencies acting as root drivers influencing technical, financial, and awareness-related challenges. Based on these findings, the study proposes a four pillar conceptual strategic framework encompassing human capital development, regulatory and standardization enablement, awareness and demand generation, and organizational and collaborative enhancement. The framework is explicitly derived from empirical results, linking barrier clusters to prioritized strategies, thereby enhancing its practical applicability. This study contributes to the existing literature by providing one of the first multi-province empirical assessments of BIM adoption in the KRG residential sector, integrating statistical validation with strategic development, and offering transferable insights for other developing regions at a similar stage of BIM adoption.

30 June 2026 in Journal of Studies in Science and Engineering
Verified
Journal Article
Open access
PDF file
MOMuhammad Ismaiel Omer
Muhammad Ismaiel Omer
SMSirwan Khuthur Malla
Sirwan Khuthur Malla
NPNzar Shakr Piro
Nzar Shakr Piro
HHHemn Omer Hamad-Ameen
Hemn Omer Hamad-Ameen
OAOmar Warani Aziz
Omar Warani Aziz
Ahmed Salih MohammedAhmed Salih Mohammed
Ahmed Salih Mohammed
The maturity technique offers a practical approach for forecasting early-age strength development. This study aimed to evaluate the accuracy of Giatec's SmartRock sensors by comparing their measurements with conventional specimen test results derived from the maturity index. Twelve concrete combinations were evaluated, with compressive strengths ranging from 20 to 45 MPa. The nine concrete mixes were designed with varying proportions of cement, sand, coarse aggregate, water, and admixture, as summarised in Table 1. The cement content ranged from 290 to 430 kg/m³, water-to-cement ratios varied from 0.27 to 0.51, and admixture dosages ranged from 0.5% to 1.2% by weight of cement, depending on the desired strength level (20-63 MPa). Cylinder tests performed at 1, 3, 7, 14, and 28 days provided the data necessary to calibrate the maturity–strength relationships. The resulting correlations between compressive strength and maturity index showed excellent accuracy, with coefficients of determination (R²) ranging from 0.986 to 0.999 across all twelve mixes (20-45 MPa). These results confirm that the SmartRock maturity method reliably predicts early-age strength and offers real-time assessment of in-situ concrete performance. The best-fit Vipulanandan models yielded coefficients of determination (R²) ranging from 0.986 to 0.999, demonstrating excellent agreement between sensor-predicted and laboratory-measured strengths. Predicted early-age strengths (3–7 days) differed from test values by less than 5%, confirming the reliability of the SmartRock system for field applications. The study concludes that the maturity method, when properly calibrated, provides a robust and non-destructive means to predict in-place concrete strength in real time, enabling faster formwork removal and improved construction quality control.