Electromyography (EMG) devices are well-suited for measuring the behaviour of muscles during an exercise or a task, and are widely used in many different research areas. Their disadvantage is that commercial systems are expensive. We designed a low-cost EMG system with enough accuracy and reliability to be used in a wide range of possible ways. The present article focuses on the validation of the low-cost system we designed, which is compared with a commercially available, accurate device. The evaluation was done by means of a set of experiments, in which volunteers performed isometric and dynamic exercises while EMG signals from the rectus femoris muscle were registered by both the proposed low-cost system and a commercial system simultaneously. Analysis and assessment of three indicators to estimate the similarity between both signals were developed. These indicated a very good result, with spearman’s correlation averaging above 0.60, the energy ratio close to the 80% and the linear correlation coefficient approximating 100%. The agreement between both systems (custom and commercial) is excellent, although there are also some limitations, such as the delay of the signal (<1 s) and noise due to the hardware and assembly in the proposed system.
Injuries caused by the overstraining of muscles could be prevented by means of a system which detects muscle fatigue. Most of the equipment used to detect this is usually expensive. The question then arises whether it is possible to use a low-cost surface electromyography (sEMG) system that is able to reliably detect muscle fatigue. With this main goal, the contribution of this work is the design of a low-cost sEMG system that allows assessing when fatigue appears in a muscle. To that aim, low-cost sEMG sensors, an Arduino board and a PC were used and afterwards their validity was checked by means of an experiment with 28 volunteers. This experiment collected information from volunteers, such as their level of physical activity, and invited them to perform an isometric contraction while an sEMG signal of their quadriceps was recorded by the low-cost equipment. After a wavelet filtering of the signal, root mean square (RMS), mean absolute value (MAV) and mean frequency (MNF) were chosen as representative features to evaluate fatigue. Results show how the behaviour of these parameters across time is shown in the literature coincides with past studies (RMS and MAV increase while MNF decreases when fatigue appears). Thus, this work proves the feasibility of a low-cost system to reliably detect muscle fatigue. This system could be implemented in several fields, such as sport, ergonomics, rehabilitation or human-computer interactions.
Surface electromyography (sEMG) is a critical tool for quantifying muscle activity and inferring biomechanical function, enabling the detection of neuromuscular deficits through the analysis of electrical potential propagation. However, the inherent variability in sEMG signal amplitude, influenced by factors such as electrode placement, equipment characteristics, and individual physiology, necessitates robust normalization techniques for accurate comparative analysis. This study investigates the reliability and effectiveness of several normalization methods in the context of bicep and tricep muscle activation during dynamic and isometric exercises: maximum voluntary contraction (MVC), submaximal voluntary contraction (SMVC), remote voluntary contraction (RVC), mean, and peak normalization. We conducted a comprehensive experimental protocol involving healthy volunteers, capturing sEMG signals during controlled bicep curls, tricep extensions, and isometric contractions. The efficacy of each normalization method was evaluated based on its ability to minimize inter-subject variability and enhance signal consistency. Specifically, while SMVC, MVC, and RVC methods exhibited generally superior performance in normalizing bicep and tricep signals, the optimal method varied depending on the task and muscle, providing consistent and reliable data for biomechanical analysis. These results underscore the importance of selecting appropriate normalization techniques to improve the accuracy of sEMG-based assessments in clinical and sports biomechanics, contributing to the development of more effective rehabilitation protocols and performance enhancement strategies.
Nowadays, due to the advances and the increasing implementation of the autonomous braking systems in vehicles, the non-collision accident is expected to become more common than a crash when a sudden stop happens. The most common injury in this kind of accident is whiplash or cervical injury since the neck has high sensitivity to sharp deceleration. To date, biomechanical research has usually been developed inside laboratories and does not entirely represent real conditions (e.g., restraint systems or surroundings of the experiment). With the aim of knowing the possible neck effects and consequences of an automatic emergency braking inside an autonomous bus, a surface electromyography (sEMG) system built by low-cost elements and developed by us, in tandem with other devices, such as accelerometers or cameras, were used. Moreover, thanks to the collaboration of 18 participants, it was possible to study the non-collision effects in two different scenarios (braking test in which the passenger is seated and looking ahead while talking with somebody in front of him (BT1) and, a second braking test where the passenger used a smartphone (BT2) and nobody is seated in front of him talking to him). The aim was to assess the sEMG neck response in the most common situations when somebody uses some kind of transport in order to conclude which environments are riskier regarding a possible cervical injury.
Nowadays, autonomous vehicles are increasing, and the driving scenario that includes both autonomous and human-driven vehicles is a fact. Knowing the driving styles of drivers in the process of automating vehicles is interest in order to make driving as natural as possible. To this end, this article presents a first approach to the design of a controller for the braking system capable of imitating the different manoeuvres that any driver performs while driving. With this aim, different experimental tests have been carried out with a vehicle instrumented with sensors capable of providing real-time information related to the braking system. The experimental tests consist of reproducing a series of braking manoeuvres at different speeds on a flat floor track following a straight path. The tests distinguish between three types of braking manoeuvre: maintained, progressive and emergency braking, which cover all the driving circumstances in which the braking system may intervene. This article presents an innovative approach to characterise braking types thanks to the methodology of analysing the data obtained by sensors during experimental tests. The characterisation of braking types makes it possible to dynamically classify three driving styles: cautious, normal and aggressive. The proposed classifications allow it possible to identify the driving styles on the basis of the pressure in the hydraulic brake circuit, the force exerted by the driver on the brake pedal, the longitudinal deceleration and the braking power, knowing in all cases the speed of the vehicle. The experiments are limited by the fact that there are no other vehicles, obstacles, etc. in the vehicle’s environment, but in this article the focus is exclusively on characterising a driver with methods that use the vehicle’s dynamic responses measured by on-board sensors. The results of this study can be used to define the driving style of an autonomous vehicle.