João Pedro Aquiles Carobolante

Dr. João Pedro Aquiles Carobolante

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
JCJoão Pedro Aquiles Carobolante
João Pedro Aquiles Carobolante
AJAdelvam Pereira Júnior
Adelvam Pereira Júnior
CJCelso Bortolini Junior
Celso Bortolini Junior
KSKerolene Barboza da Silva
Kerolene Barboza da Silva
Roberta M. SabinoRoberta M. Sabino
Roberta M. Sabino
ACANA PAULA ROSIFINI ALVES CLARO
ANA PAULA ROSIFINI ALVES CLARO
The study of new metallic biomaterials for application in bone tissue repair has improved due to the increase in life expectancy and the aging of the world population. Titanium alloys are one of the main groups of biomaterials for these applications, and beta-type titanium alloys are more suitable for long-term bone implants. The objective of this work was to process and characterize a new Ti10Mo8Nb6Zr beta alloy. Alloy processing involves arc melting, heat treatment, and cold forging. The characterization techniques used in this study were X-ray fluorescence spectroscopy, X-ray diffraction, differential scanning calorimetry, optical microscopy, microhardness measurements, and pulse excitation technique. In vitro studies using adipose-derived stem cells (ADSC) were performed to evaluate the cytotoxicity and cell viability after 1, 4, and 7 days. The results showed that the main phase during the processing route was the beta phase. At the end of processing, the alloy showed beta phase, equiaxed grains with an average size of 228.7 µm, and low Young’s modulus (83 GPa). In vitro studies revealed non-cytotoxicity and superior cell viability compared to CP Ti. The addition of zirconium led to a decrease in the beta-transus temperature and Young’s modulus and improved the biocompatibility of the alloy. Therefore, the Ti10Mo8Nb6Zr alloy is a promising candidate for application in the biomedical field.

21 June 2022 in Metals
Verified
Journal Article
Open access
PDF file
PCPatrícia Capellato
Patrícia Capellato
FVFilipe Bueno Vilela
Filipe Bueno Vilela
AFAndres Henrique Palomo Fontenele
Andres Henrique Palomo Fontenele
GSGilbert Silva
Gilbert Silva
KSKerolene Barboza da Silva
Kerolene Barboza da Silva
Daniela SachsDaniela Sachs
Daniela Sachs
The growth of the elderly population is urging for more suitable biomaterials to allow the performance of better surgical and implant procedures and accelerate the patient’s healing because the elderly are more vulnerable to orthopedic and dental problems. β-phase Ti alloys can improve the mechanical properties of implants by reducing their elastic modulus and, consequently, the effects of stress shielding within bones. Therefore, the objective of this article is to study a novel ternary β-phase alloy of Ti10Mo8Nb produced by an electric arc furnace and rotary forge. The microstructure and mechanical properties of the Ti10Mo8Nb alloy were investigated in order to evaluate its suitability for biomedical applications and compare its characteristics with those present in Ti-alloys commerced or widely researched for prosthetic purposes. A tensile test, Vickers microhardness test, use of microstructure of optical microscopy for examination of microstructure, X-ray diffraction and hemolysis analysis were carried out. Thus, the Ti10Mo8Nb alloy showed suitable properties for biomedical applications, as well as having the potential to reduce the possibility to occur stress shielding after prosthetic implantations, especially for orthopedics and dentistry.

28 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
KSKerolene Barboza da Silva
Kerolene Barboza da Silva
JCJoão Pedro Aquiles Carobolante
João Pedro Aquiles Carobolante
SSSUDHAGARA RAJAN SOUNDARARAJAN
SUDHAGARA RAJAN SOUNDARARAJAN
CJCelso Bortolini Júnior
Celso Bortolini Júnior
Roberta M. SabinoRoberta M. Sabino
Roberta M. Sabino
ACANA PAULA ROSIFINI ALVES CLARO
ANA PAULA ROSIFINI ALVES CLARO
This study aims to characterize a new Ti-25Ta-25Nb-5Sn alloy for biomedical application. Microstructure, phase formation, mechanical and corrosion properties, along with the cell culture study of the Ti-25Ta-25Nb alloy with Sn content 5 mass% are presented in this article. The experimental alloy was processed in an arc melting furnace, cold worked, and heat treated. For characterization, optical microscopy, X-ray diffraction, microhardness, and Young’s modulus measurements were employed. Corrosion behavior was also evaluated using open-circuit potential (OCP) and potentiodynamic polarization. In vitro studies with human ADSCs were performed to investigate cell viability, adhesion, proliferation, and differentiation. Comparison among the mechanical properties observed in other metal alloy systems, including CP Ti, Ti-25Ta-25Nb, and Ti-25Ta-25-Nb-3Sn showed an increase in microhardness and a decrease in the Young’s modulus when compared to CP Ti. The potentiodynamic polarization tests indicated that the corrosion resistance of the Ti-25Ta-25Nb-5Sn alloy was similar to CP Ti and the experiments in vitro demonstrated great interactions between the alloy surface and cells in terms of adhesion, proliferation, and differentiation. Therefore, this alloy presents potential for biomedical applications with properties required for good performance.

18 June 2018 in Materials Research
Verified
Journal Article
Open access
PDF file
JCJoão Pedro Aquiles Carobolante
João Pedro Aquiles Carobolante
CPCristiane Aparecida Pereira
Cristiane Aparecida Pereira
MDMarcela Ferreira Dias-Netipanyj
Marcela Ferreira Dias-Netipanyj
Ketul C PopatKetul C Popat
Ketul C Popat
ACANA PAULA ROSIFINI ALVES CLARO
ANA PAULA ROSIFINI ALVES CLARO
The purpose of this study is the surface modification of Ti10Mo8Nb experimental alloy by using TiO2 nanostructure growth. Ingots of the Ti10Mo8Nb experimental alloy were produced by fusion from sheets of molybdenum, niobium, and titanium commercially pure in an arc melting furnace under argon atmosphere. The potentiostatic anodic oxidation was performed using an electrolyte formed of glycerol and H2O (1: 1 by vol.) with the addition of 2.7% (w/v) NH4F under 20 V for 3 h at room temperature. After the surface treatment, the samples were annealing. The surface of the alloy was analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD), contact angle, surface energy measurements. In vitro studies, such as cell and bacterial adhesion, were performed to evaluate the response of this treatment. The Ti10Mo8Nb alloy exhibited beta phase after the processing. After the surface treatment, a nanoporous layer of TiO was obtained. The anatase phase was found in the annealed samples (450 ºC for 3 hours). In vitro analyzes showed cell growth viability and decreased bacterial proliferation due to the larger specific surface area.

20 April 2025 in Metals
Verified
Journal Article
Open access
PDF file
KSKerolene Barboza da Silva
Kerolene Barboza da Silva
JCJoão Pedro Aquiles Carobolante
João Pedro Aquiles Carobolante
RNRoberto Zenhei Nakazato
Roberto Zenhei Nakazato
AFAngelo Caporalli Filho
Angelo Caporalli Filho
ACANA PAULA ROSIFINI ALVES CLARO
ANA PAULA ROSIFINI ALVES CLARO
Recent studies have focused on developing temporary metallic implants made from biodegradable biomaterials, such as iron and its alloys, along with the associated manufacturing methods. These biomaterials allow the implant to gradually degrade after fulfilling its function, which reduces the risks of complications associated with permanent implants. Iron is particularly appealing from a structural standpoint, and adding manganese enhances its potential for use. The Fe-35Mn alloy demonstrates excellent mechanical properties and degradation characteristics, making it an ideal choice within the Fe-Mn system. As a result, new processing techniques can be applied to this alloy to further improve its performance. The objective of this research is to propose a new processing route and evaluate its impact on the properties of the Fe-35Mn alloy. The experimental alloy was produced using an arc melting furnace, followed by homogenization, hot swaging, and solution treatment. Alloy characterization was conducted using various techniques, including X-ray fluorescence (XRF), optical microscopy (OM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), microhardness testing, tensile strength measurements, Young’s modulus determination, and potentiodynamic polarization analysis. The microstructural evolution throughout the applied processing route was analyzed in relation to the alloy’s mechanical performance and corrosion resistance. The typical microstructure of the Fe-35Mn alloy is primarily composed of austenitic grains stabilized at room temperature. Its mechanical properties—yield strength (297 MPa), ultimate tensile strength (533 MPa), and elongation to failure (39%)—are comparable to, or even surpass, those of conventional biomedical materials such as 316 L stainless steel and pure iron. The reduced Young’s modulus (171 GPa), compared to other alloys, further underscores its potential for biomedical applications. Electrochemical testing revealed lower corrosion resistance than that of similar alloys reported in the literature, with a corrosion potential of −0.76 V and a current density of 3.88 µA·cm−2, suggesting an enhanced corrosion rate.

19 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Talita Kathleen Correia SousaTalita Kathleen Correia Sousa
Talita Kathleen Correia Sousa
F.Raquel MaiaF.Raquel Maia
F.Raquel Maia
Sandra PinaSandra Pina
Sandra Pina
RRRui M. Reis
Rui M. Reis
Joaquim OliveiraJoaquim Oliveira
Joaquim Oliveira
ACANA PAULA ROSIFINI ALVES CLARO
ANA PAULA ROSIFINI ALVES CLARO
This study focuses on the surface modification of Ti6Al4V scaffolds produced through additive manufacturing using the Powder-Bed Fusion Electron-Beam Melting (PBF-EB) technique. From our perspective, this technique has the potential to enhance implant osseointegration, involving the growth of a layer of titanium dioxide nanotubes (TiO2) on surfaces through anodic oxidation. Scaffolds with anodized surfaces were characterized, and the formation of a nanoporous and crystalline TiO2 layer was confirmed. The analysis of cell morphology revealed that cells adhered to the anodized surfaces through their filopodia, which led to proliferation during the initial hours. However, it was observed that the adhesion of Saos-2 cells was lower on anodized scaffolds compared to both built and chemically polished scaffolds throughout the cell culture period. The results obtained here suggest that while anodic oxidation is effective in achieving a nanoporous surface, cell adhesion and interaction were affected by the weak adhesion of cell filopodia to the surface. Thus, combining surface treatment techniques to create micro- and nanopores may be an effective alternative for achieving a favorable cellular response when the objective is to enhance the performance of porous titanium scaffolds in the short term.