Objective quantification of hand functions using sensorized devices has gained recognition lately in clinical practice. Traditional clinical assessment scales lack precision and quantifiability, prompting the exploration of new methodologies. The following work focuses on the design, development, and testing of a sensorized key rig that can be used to perform quantifiable metrics of hand functions. Leveraging advancements in sensor technology, the study developed an instrumented key rig equipped with an off-center load cell for accurate pinch force measurement. Additionally, a magnetic rotary encoder was added to track the key-turning movement. Calibration and testing procedures ensured the rig’s reliability and repeatability. Results demonstrated consistent and precise measurements with the reliability ICC of p =0.99996, highlighting the key rig device potential for clinical motor function assessment and rehabilitation monitoring. Further research could explore its comparative effectiveness and clinical applications with stroke survivors.
Robotic cadaveric testing provides a controlled approach to studying knee ligament biomechanics under continuous motion, addressing limitations in static or mechanical loading testing. Our study describes an alternative method for soft-tissue strain measurement, followed by an investigation of this method on knee ligament strain and joint kinematics using a six-degree-of-freedom robotic system equipped with force and torque sensors. Six cadaveric knee specimens underwent controlled 90° flexion cycles, with uniaxial strain gauges sutured to the ACL, PCL, MCL, and LCL for strain measurement. Results indicate that the LCL exhibited the highest extension at 1.63 mm, while the ACL showed minimal extension at 0.09 mm. The MCL were at −0.76 mm and PCL at −1.76 mm contraction, suggesting a stabilizing function under flexion. Varus torque at 2.18 Nm at 90° flexion correlated with LCL strain, and PCL translation variability reflected its multi-planar engagement. These findings confirm ligament-specific strain responses under dynamic loading, highlighting that the LCL and PCL undergo the most significant length changes.
This paper presents a pilot study that uses a markerless motion capture system to measure active shoulder joint range of motion in a clinic room. The measurements from this automated method are compared with manual measurements done by a clinician using a goniometer. All the parameters from both methods are positively correlated. The root-mean-square differences from the comparisons are in the range of 7.21° – 15.87° depending on the type of angles. With a careful protocol design and execution, the markerless motion capture system can potentially be used as an objective shoulder range of motion assessment tool in clinical practice.