High brightness electron sources for linac based free-electron lasers (FELs) are being developed at the Photo Injector Test facility at DESY, Zeuthen site (PITZ). Production of electron bunches with extremely small transverse emittance is the focus of the PITZ scientific program. The photoinjector optimization in 2008–2009 for a bunch charge of 1, 0.5, 0.25, and 0.1 nC resulted in measured emittance values which are beyond the requirements of the European XFEL [S. Rimjaem et al., Nucl. Instrum. Methods Phys. Res., Sect. A 671, 62 (2012)]. Several essential modifications were commissioned in 2010–2011 at PITZ, resulting in further improvement of the photoinjector performance. Significant improvement of the rf gun phase stability is a major contribution in the reduction of the measured transverse emittance. The old TESLA prototype booster was replaced by a new cut disk structure cavity. This allows acceleration of the electron beam to higher energies and supports much higher flexibility for stable booster operation as well as for longer rf pulses which is of vital importance especially for the emittance optimization of low charge bunches. The transverse phase space of the electron beam was optimized at PITZ for bunch charges in the range between 0.02 and 2 nC, where the quality of the beam measurements was preserved by utilizing long pulse train operation. The experimental optimization yielded worldwide unprecedented low normalized emittance beams in the whole charge range studied.
12 March 2025 in Physical Review Accelerators and Beams
We report on the operation of the first high peak and average power single-pass terahertz free-electron laser (THz FEL) based on a high-brightness photoinjector for developing a THz source for pump-probe experiments at advanced x-ray FELs (XFELs). Electron beams with 17 MeV / c momentum and charge up to 2.4 nC were used to generate narrow-band 3 THz radiation with pulse energies of more than 0.1 mJ. The novelty of the realized method is that the undulator radiation by electron beams is much longer than the radiation wavelength, with FEL starting from coherent beam contribution rather than shot noise. This proved to be not a simple scaling of the XFEL mechanism due to the significant role of the bunching factor in the considered case.
Due to their excellent photoemissive properties, especially low thermal emittance and high sensitivity in the green wavelength, multi-alkali antimonide photocathodes, in particular, cesium–potassium–antimonide, emerged as prominent photoemissive materials for the electron sources of high-repetition-rate FEL applications. To explore its feasibility of operating in a high-gradient RF gun, DESY collaborated with INFN LASA to develop multi-alkali photocathode materials. In this report, we describe the recipe of K-Cs-Sb photocathodes, which were grown on a Mo substrate by varying the foundational Sb layer thickness using sequential deposition techniques. This report also illustrates the information regarding the film thickness, substrate temperature, deposition rate, and its possible effects on the photocathode’s properties. In addition, the influence of temperature on the cathode degradation is also summarized. Furthermore, in the framework of density functional theory (DFT), we investigated the electronic and optical properties of the K2CsSb material. The optical properties, such as dielectric function, reflectivity, refracting index, and extinction coefficient, were evaluated. The correlation between the calculated and measured optical properties, such as reflectivity, provides a better and more efficient strategy to rationalize and understand the photoemissive material’s properties.
8 August 2022 in Physical Review Accelerators and Beams
Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy (>= 100 MeV) photoinjectors at SwissFEL and European x-ray free electron laser (XFEL) have reported much higher slice energy spread than expected at their XFEL working points (200-250 pC). In this paper, a new method for measuring slice energy spread at lower beam energy (similar to 20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen, and the results for 250 pC are much lower than those measured at high energy injectors.
6 February 2019 in Plasma Physics and Controlled Fusion
We present a new method to determine the electron density of a plasma by measuring the periodicity of modulations introduced to the longitudinal phase space of a relativistic particle bunch by the interaction with the plasma via the self modulation instability. As the modulation is solely depending on the plasma density and the beam parameters, this method allows to determine the time resolved density of a plasma at the position of beam passage, which is confirmed in particle-in-cell simulations. Densities in the range of 3.6 x 1012 cm-3 to 7.2 x 1015 cm-3 have been measured and the measurement accuracy is confirmed by comparison to spectroscopic plasma density measurements.
5 May 2004 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment