Electron photoinjectors provide high-brightness electron beams to numerous research applications in physics, chemistry, material, and life sciences. Semiconductor photocathodes are widely used here, as they enable the production of low-emittance beams with variable charge at high repetition rates. One of the key figures of merit of photocathodes is the minimum achievable bunch length. In semiconductor cathodes, this is dominated by scattering effects and varying penetration depths of the extracting photons, which leads to a characteristic electron emission function. We present a method to determine this cathode time response with resolution on the tens of femtoseconds level, breaking the resolution barrier encountered in previous studies. The method is demonstrated with cesium-telluride (Cs2Te) and gold cathodes, revealing response times of (184 ± 41) fs up to (253 ± 58) fs for the semiconductor and an upper limit of (93 ± 17) fs for the metal. Monte Carlo simulations of Cs2Te emission benchmarked to these results give detailed information about the cathode material.
Due to their excellent photoemissive properties, especially low thermal emittance and high sensitivity in the green wavelength, multi-alkali antimonide photocathodes, in particular, cesium–potassium–antimonide, emerged as prominent photoemissive materials for the electron sources of high-repetition-rate FEL applications. To explore its feasibility of operating in a high-gradient RF gun, DESY collaborated with INFN LASA to develop multi-alkali photocathode materials. In this report, we describe the recipe of K-Cs-Sb photocathodes, which were grown on a Mo substrate by varying the foundational Sb layer thickness using sequential deposition techniques. This report also illustrates the information regarding the film thickness, substrate temperature, deposition rate, and its possible effects on the photocathode’s properties. In addition, the influence of temperature on the cathode degradation is also summarized. Furthermore, in the framework of density functional theory (DFT), we investigated the electronic and optical properties of the K2CsSb material. The optical properties, such as dielectric function, reflectivity, refracting index, and extinction coefficient, were evaluated. The correlation between the calculated and measured optical properties, such as reflectivity, provides a better and more efficient strategy to rationalize and understand the photoemissive material’s properties.
8 August 2022 in Physical Review Accelerators and Beams
Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy (>= 100 MeV) photoinjectors at SwissFEL and European x-ray free electron laser (XFEL) have reported much higher slice energy spread than expected at their XFEL working points (200-250 pC). In this paper, a new method for measuring slice energy spread at lower beam energy (similar to 20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen, and the results for 250 pC are much lower than those measured at high energy injectors.
1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons' transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons' transverse momenta. Both simulations and proof of principle experiments are reported.