Sushil Sharma

Dr. Sushil Sharma


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
PMPawel Moskal
Pawel Moskal
AGAleksander Gajos
Aleksander Gajos
MMM. Mohammed
M. Mohammed
JCJ. Chhokar
J. Chhokar
NCN. Chug
N. Chug
WWW. Wiślicki
W. Wiślicki
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron–positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10−4, with an over threefold improvement on the previous measurement.

5 June 2020 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
SSSushil Sharma
Sushil Sharma
JCJ. Chhokar
J. Chhokar
CCC. Curceanu
C. Curceanu
ECE. Czerwiński
E. Czerwiński
MDM. Dadgar
M. Dadgar
PMP. Moskal
P. Moskal
Purpose: The time-over-threshold (TOT) technique is being used widely due to itsimplications in developing the multi-channel readouts, mainly when fast signal processing is required. Using the TOT technique, as a measure of energy loss instead of charge integration methods, significantly reduces the signal readout costs by combining the time and energy information. Therefore, this approach can potentially be utilized in J-PET tomograph which is built from plastic scintillators characterized by fast light signals. The drawback in adopting this technique lies in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it by the J-PET tomograph setup. Methods: The experiment was performed using a 22Na beta emitter source placed in the center of the J-PET tomograph. This isotope produces photons of two different energies: 511 keV photons from the positron annihilation (direct annihilation or through the formation of a para-positronium atom or pick-off process of ortho-positronium atoms) and a 1275 keV prompt photon. This allows the study of the correlation between TOT values and energy loss for energy ranges up to 1000 keV. Since the photon interacts predominantly via Compton scattering inside the plastic scintillator, there is no direct information of the energy deposition. However, using the J-PET geometry, one can measure the scattering angle of the interacting photon. Since the 22Na source emits photons of two different energies, it is necessary to know unambiguously the energy of incident photons and their corresponding scattering angles in order to estimate energy deposition. In summary, this work presents a dedicated algorithm developed to tag photons of different energies and studying their scattering angles to calculate the energy deposition by the interacting photons. Results: A new method was elaborated to measure the energy loss by photons interacting with plastic scintillators used in the J-PET tomograph. We find the relationship between the energy loss and TOT is non-linear and can be described by the functions TOT = A0 + A1 * ln(E dep + A2) + A3 * (ln(E dep + A2))2 and TOT = A0 - A1 * A2 $^{E_{dep}}\phantom {\dot {i}\!}$ E dep . In addition, we also introduced a theoretical model to calculate the TOT as a function of energy loss in plastic scintillators. Conclusions: A relationship between TOT and energy loss by photons interacting inside the plastic scintillators used in J-PET scanner is established for a deposited energy range of 100–1000 keV.

2 May 2025 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
DKDeepak Kumar
Deepak Kumar
SSSushil Sharma
Sushil Sharma
EBErmias Yitayew Beyene
Ermias Yitayew Beyene
NCNeha Chug
Neha Chug
KEKavya Valsan Eliyan
Kavya Valsan Eliyan
In state-of-the-art positron emission tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and parapositronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening avenues for exploring polarization correlations in PET as a diagnostic indicator.

2 January 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
PMPawel Moskal
Pawel Moskal
ECEryk Czerwiński
Eryk Czerwiński
JRJuhi Raj
Juhi Raj
SBSteven D. Bass
Steven D. Bass
EBErmias Y. Beyene
Ermias Y. Beyene
WWWojciech Wiślicki
Wojciech Wiślicki
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of 10−4 signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

1 August 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
KDKamil Dulski
Kamil Dulski
SBSteven D. Bass
Steven D. Bass
JCJ. Chhokar
J. Chhokar
NCN. Chug
N. Chug
CCCatalina Curceanu
Catalina Curceanu
PMPawel Moskal
Pawel Moskal

26 June 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
ABAleksander Bilewicz
Aleksander Bilewicz
MDManish Das
Manish Das
BHBangyan Huang
Bangyan Huang
AKAleksander Khreptak
Aleksander Khreptak
Ewa Łucja StępieńEwa Łucja Stępień
Ewa Łucja Stępień
Positronium imaging was recently proposed to image the properties of positronium atoms in the patient’s body. Positronium properties depend on the size of intramolecular voids and oxygen concentration; therefore, they deliver information different from the anatomic, morphological, and metabolic images. Thus far, the mean ortho-positronium lifetime imaging has been at the center of research interest. The first ex vivo and in vivo positronium lifetime images of humans have been demonstrated with the dedicated J-PET scanner, enabling simultaneous registration of annihilation photons and prompt gamma from β+γ emitters. Annihilation photons are used to reconstruct the annihilation place and time, while prompt gamma is used to reconstruct the time of positronium formation. This review describes recent achievements in the translation of positronium imaging into clinics. The first measurements of positronium lifetime in humans with commercial PET scanners modernized to register triple coincidences are reported. The in vivo observations of differences in ortho-positronium lifetime between tumor and healthy tissues and between different oxygen concentrations are discussed. So far, the positronium lifetime measurements in humans have been completed with clinically available 68Ga, 82Rb, and 124I radionuclides. Status and challenges in developing positronium imaging on a way to a clinically useful procedure are presented and discussed.