Victor H. Pérez-Luna

Dr. Victor H. Pérez-Luna


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2018 in Gels
Verified
Journal Article
Open access
PDF file
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna
Orfil González-ReynosoOrfil González-Reynoso
Orfil González-Reynoso
Hydrogels are materials specially suited for encapsulation of biological elements. Their large water content provides an environment compatible with most biological molecules. Their crosslinked nature also provides an ideal material for the protection of encapsulated biological elements against degradation and/or immune recognition. This makes them attractive not only for controlled drug delivery of proteins, but they can also be used to encapsulate cells that can have therapeutic applications. Thus, hydrogels can be used to create systems that will deliver required therapies in a controlled manner by either encapsulation of proteins or even cells that produce molecules that will be released from these systems. Here, an overview of hydrogel encapsulation strategies of biological elements ranging from molecules to cells is discussed, with special emphasis on therapeutic applications.

1 July 2004 in Journal of Fluorescence
Verified
Journal Article
Closed access
PDF file
KAKadir Aslan
Kadir Aslan
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna

11 September 2013 in Pharmaceutical Research
Verified
Journal Article
Closed access
PDF file
PDPawel W. Drapala
Pawel W. Drapala
BJBin Jiang
Bin Jiang
YCYu-Chieh Chiu
Yu-Chieh Chiu
WMWilliam F. Mieler
William F. Mieler
EBEric M. Brey
Eric M. Brey
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna

25 September 2023 in Coatings
Verified
Journal Article
Open access
PDF file
JAJosé Acosta
José Acosta
Mario Alberto Garcia-RamirezMario Alberto Garcia-Ramirez
Mario Alberto Garcia-Ramirez
Gabriela Hinojosa-VenturaGabriela Hinojosa-Ventura
Gabriela Hinojosa-Ventura
ÁMÁlvaro J. Martínez-Gómez
Álvaro J. Martínez-Gómez
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna
Orfil González-ReynosoOrfil González-Reynoso
Orfil González-Reynoso
In recent years, the utilization of microfluidic devices for precise manipulation of small flows has significantly increased. The effective management of microfluidics is closely associated with microchannel fabrication. The fabrication method employed for microfluidic devices directly impacts the roughness of the microchannels, consequently influencing the flows within them. In this study, the surface roughness of microchannels was investigated through three different fabrication processes: PDMS lithography, PLA printing, and UV resin printing. This research compared and analyzed the surface roughness of the microchannels fabricated using these methods. Furthermore, supported by a dynamic fluid simulator, the impact of surface roughness on flow behavior was shown. Results reveal varying degrees of roughness prominence in curved regions. Comparing microfluidic device fabrication techniques is crucial to optimize the process, control roughness, analyze flow rates, and select a proper material to be used in the development of microfluidic devices.

5 January 2012 in Journal of Fluorescence
Verified
Journal Article
Closed access
PDF file
YCYu-Chieh Chiu
Yu-Chieh Chiu
EBEric M. Brey
Eric M. Brey
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna

10 March 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JAJosé Acosta
José Acosta
José González-GarcíaJosé González-García
José González-García
Mario Alberto Garcia-RamirezMario Alberto Garcia-Ramirez
Mario Alberto Garcia-Ramirez
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna
ELErick Omar Cisneros López
Erick Omar Cisneros López
Orfil González-ReynosoOrfil González-Reynoso
Orfil González-Reynoso
Photopolymerized microparticles are made of biocompatible hydrogels like Polyethylene Glycol Diacrylate (PEGDA) by using microfluidic devices are a good option for encapsulation, transport and retention of biological or toxic agents. Due to the different applications of these microparticles, it is important to investigate the formulation and the mechanical properties of the material of which they are made of. Therefore, in the present study, mechanical tests were carried out to determine the swelling, drying, soluble fraction, compression, cross-linking density (Mc) and mesh size (ξ) properties of different hydrogel formulations. Tests provided sufficient data to select the best formulation for the future generation of microparticles using microfluidic devices. The initial gelation times of the hydrogels formulations were estimated for their use in the photopolymerization process inside a microfluidic device. Obtained results showed a close relationship between the amount of PEGDA used in the hydrogel and its mechanical properties as well as its initial gelation time. Consequently, it is of considerable importance to know the mechanical properties of the hydrogels made in this research for their proper manipulation and application. On the other hand, the initial gelation time is crucial in photopolymerizable hydrogels and their use in continuous systems such as microfluidic devices.