José Acosta

Mr. José Acosta

N/A

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2023 in Coatings
Verified
Journal Article
Open access
PDF file
JAJosé Acosta
José Acosta
Mario Alberto Garcia-RamirezMario Alberto Garcia-Ramirez
Mario Alberto Garcia-Ramirez
Gabriela Hinojosa-VenturaGabriela Hinojosa-Ventura
Gabriela Hinojosa-Ventura
ÁMÁlvaro J. Martínez-Gómez
Álvaro J. Martínez-Gómez
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna
Orfil González-ReynosoOrfil González-Reynoso
Orfil González-Reynoso
In recent years, the utilization of microfluidic devices for precise manipulation of small flows has significantly increased. The effective management of microfluidics is closely associated with microchannel fabrication. The fabrication method employed for microfluidic devices directly impacts the roughness of the microchannels, consequently influencing the flows within them. In this study, the surface roughness of microchannels was investigated through three different fabrication processes: PDMS lithography, PLA printing, and UV resin printing. This research compared and analyzed the surface roughness of the microchannels fabricated using these methods. Furthermore, supported by a dynamic fluid simulator, the impact of surface roughness on flow behavior was shown. Results reveal varying degrees of roughness prominence in curved regions. Comparing microfluidic device fabrication techniques is crucial to optimize the process, control roughness, analyze flow rates, and select a proper material to be used in the development of microfluidic devices.

22 April 2025 in Gels
Verified
Journal Article
Open access
PDF file
Gabriela Hinojosa-VenturaGabriela Hinojosa-Ventura
Gabriela Hinojosa-Ventura
JAJosé Acosta
José Acosta
CVCarlos Arnulfo Velázquez-Carriles
Carlos Arnulfo Velázquez-Carriles
Diego Eloyr Navarro-LópezDiego Eloyr Navarro-López
Diego Eloyr Navarro-López
MLMiguel Ángel López-Alvarez
Miguel Ángel López-Alvarez
JJJorge Manuel Silva Jara
Jorge Manuel Silva Jara
Hydrogel particles are essential in biological applications because of their distinctive capacity to retain water and encapsulate active molecules within their three-dimensional structure. Typical particle sizes range from nanometers (10–500 nm) to micrometers (1–500 µm), depending on the specific application and method of preparation. These characteristics render them optimal carriers for the administration of active compounds, facilitating the regulated and prolonged release of pharmaceuticals, including anticancer agents, antibiotics, and therapeutic proteins. Hydrogel particles can exhibit various morphologies, including spherical, rod-shaped, disk-shaped, and core–shell structures. Each shape offers distinct advantages, such as improved circulation time, targeted drug delivery, or enhanced cellular uptake. Additionally, hydrogel particles can be engineered to respond to various stimuli, such as temperature, pH, light, magnetic fields, and biochemical signals. Furthermore, their biocompatibility and capacity to acclimate to many biological conditions make them appropriate for sophisticated applications, including gene treatments, tissue regeneration, and cell therapies. Microfluidics has transformed the creation of hydrogel particles, providing precise control over their dimensions, morphology, and stability. This technique facilitates reproducible and highly efficient production, reducing reagent waste and optimizing drug encapsulation. The integration of microfluidics with hydrogels provides opportunities for the advancement of creative and effective solutions in contemporary medicine.

10 March 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JAJosé Acosta
José Acosta
José González-GarcíaJosé González-García
José González-García
Mario Alberto Garcia-RamirezMario Alberto Garcia-Ramirez
Mario Alberto Garcia-Ramirez
VPVictor H. Pérez-Luna
Victor H. Pérez-Luna
ELErick Omar Cisneros López
Erick Omar Cisneros López
Orfil González-ReynosoOrfil González-Reynoso
Orfil González-Reynoso
Photopolymerized microparticles are made of biocompatible hydrogels like Polyethylene Glycol Diacrylate (PEGDA) by using microfluidic devices are a good option for encapsulation, transport and retention of biological or toxic agents. Due to the different applications of these microparticles, it is important to investigate the formulation and the mechanical properties of the material of which they are made of. Therefore, in the present study, mechanical tests were carried out to determine the swelling, drying, soluble fraction, compression, cross-linking density (Mc) and mesh size (ξ) properties of different hydrogel formulations. Tests provided sufficient data to select the best formulation for the future generation of microparticles using microfluidic devices. The initial gelation times of the hydrogels formulations were estimated for their use in the photopolymerization process inside a microfluidic device. Obtained results showed a close relationship between the amount of PEGDA used in the hydrogel and its mechanical properties as well as its initial gelation time. Consequently, it is of considerable importance to know the mechanical properties of the hydrogels made in this research for their proper manipulation and application. On the other hand, the initial gelation time is crucial in photopolymerizable hydrogels and their use in continuous systems such as microfluidic devices.

21 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Gabriela Hinojosa-VenturaGabriela Hinojosa-Ventura
Gabriela Hinojosa-Ventura
Mario Alberto Garcia-RamirezMario Alberto Garcia-Ramirez
Mario Alberto Garcia-Ramirez
JAJosé Acosta
José Acosta
Orfil González-ReynosoOrfil González-Reynoso
Orfil González-Reynoso
The formation of microparticles (MPs) of biocompatible and biodegradable hydrogels such as polyethylene glycol diacrylate (PEGDA) utilizing microfluidic devices is an attractive option for entrapment and encapsulation of active principles and microorganisms. Our research group has presented in previous studies a formulation to produce these hydrogels with adequate physical and mechanical characteristics for their use in the formation of MPs. In this work, hydrogel MPs are formed based on PEGDA using a microfluidic device with a T-junction design, and the MPs become hydrogel through a system of photopolymerization. The diameters of the MPs are evaluated as a function of the hydrodynamic condition flow rates of the continuous (Qc) and disperse (Qd) phases, measured by optical microscopy, and characterized through scanning electron microscopy. As a result, the following behavior is found: the diameter is inversely proportional to the increase in flow in the continuous phase (Qc), and it has a significant statistical effect that is greater than that in the flow of the disperse phase (Qd). While the diameter of the MPs is proportional to Qd, it does not have a significant statistical effect on the intervals of flow studied. Additionally, the MPs’ polydispersity index (PDI) was measured for each experimental hydrodynamic condition, and all values were smaller than 0.05, indicating high homogeneity in the MPs. The microparticles have the potential to entrap pharmaceuticals and microorganisms, with possible pharmacological and bioremediation applications.