Magnesium (Mg) - based alloys are becoming attractive materials for medical applications as temporary bone implants for support of fracture healing, e.g. as a suture anchor. Due to their mechanical properties and biocompatibility, they may replace titanium or stainless-steel implants, commonly used in orthopedic field. Nevertheless, patient safety has to be assured by finding a long-term balance between metal degradation, osseointegration, bone ultrastructure adaptation and element distribution in organs. In order to determine the implant behavior and its influence on bone and tissues, we investigated two Mg alloys with gadolinium contents of 5 and 10 wt percent in comparison to permanent materials titanium and polyether ether ketone. The implants were present in rat tibia for 10, 20 and 32 weeks before sacrifice of the animal. Synchrotron radiation-based micro computed tomography enables the distinction of features like residual metal, degradation layer and bone structure. Additionally, X-ray diffraction and X-ray fluorescence yield information on parameters describing the bone ultrastructure and elemental composition at the bone-to-implant interface. Finally, with element specific mass spectrometry, the elements and their accumulation in the main organs and tissues are traced. The results show that Mg-xGd implants degrade in vivo under the formation of a stable degradation layer with bone remodeling similar to that of Ti after 10 weeks. No accumulation of Mg and Gd was observed in selected organs, except for the interfacial bone after 8 months of healing. Thus, we confirm that Mg-5Gd and Mg-10Gd are suitable material choices for bone implants.
While metal materials historically have served as permanent implants and were designed to avoid degradation, next generation bioabsorbable metals for medical devices such as vascular stents are under development, which would elute metal ions and corrosion byproducts into tissues. The fate of these eluted products and their local distribution in vascular tissue largely under studied. In this study, we employ a high spatial resolution spectrometric imaging modality, laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) to map the metal distribution, (herein refered to as laser ablation mapping, or LAM) from Mg alloys within the mouse vascular system and approximate their local concentrations. We used a novel rare earth element bearing Mg alloy (WE22) wire implanted within the abdominal aorta of transgenic hypercholesterolemic mice (APOE−/−) to simulate a bioabsorbable vascular prosthesis for up to 30 days. We describe qualitatively and semi-quantitatively implant-derived corrosion product presence throughout the tissue cross sections, and their approximate concentrations within the various vessel structures. Additionally, we report the spatial changes of corrosion products, which we postulate are mediated by phagocytic inflammatory cells such as macrophages (MΦ’s).
21 October 2022 in Biomechanics and Modeling in Mechanobiology
Flow diverter devices are small stents used to divert blood flow away from aneurysms in the brain, stagnating flow and inducing intra-aneurysmal thrombosis which in time will prevent aneurysm rupture. Current devices are formed from thin (∼25 μm) wires which will remain in place long after the aneurysm has been mitigated. As their continued presence could lead to secondary complications, an absorbable flow diverter which dissolves into the body after aneurysm occlusion is desirable. The absorbable metals investigated to date struggle to achieve the necessary combination of strength, elasticity, corrosion rate, fragmentation resistance, radiopacity, and biocompatibility. This work proposes and investigates a new composite wire concept combining absorbable iron alloy (FeMnN) shells with one or more pure molybdenum (Mo) cores. Various wire configurations are produced and drawn to 25-250 μm wires. Tensile testing revealed high and tunable mechanical properties on par with existing flow diverter materials. In vitro degradation testing of 100 μm wire in DMEM to 7 days indicated progressive corrosion and cracking of the FeMnN shell but not of the Mo, confirming the cathodic protection of the Mo by the FeMnN and thus mitigation of premature fragmentation risk. In vivo implantation and subsequent μCT of the same wires in mouse aortas to 6 months showed meaningful corrosion had begun in the FeMnN shell but not yet in the Mo filament cores. In total, these results indicate that these composites may offer an ideal combination of properties for absorbable flow diverters.
Disruption of the mitochondrial-nuclear network leads to accelerated aging and age-related diseases, including age-related macular degeneration. The current study tested the hypothesis that mitochondrial morphology could be demonstrated quantitatively using a mathematic model and mitochondrial trafficking complex under stress conditions. To test our hypothesis, normal and aberrant mitochondria were examined quantitatively based on mitochondrial size, shape, position, composition, and dynamics. Adaptation of the mitochondrial network to changes in the intracellular oxidation and reduction milieu is critical for the survival of retinal pigment epithelial cells. Our mitochondrial interactome mapping demonstrated that a positive correlation may exist between oxidative stress-mediated phosphorylation and age-related disease progression. The current interactome may provide a potential therapeutic approach to treat mitochondria-induced neurodegeneration, including age-related macular degeneration.
The underlying pathology of most cardiovascular diseases (CVDs) such as coronary artery disease, high blood pressure, and stroke involves decreased cardiovascular contractility and anatomic alterations in cardiovascular structures. Nitric oxide (NO) regulates vascular tone and contractile function of myocardium and maintains blood vessel homeostasis. Interestingly, the effect of NO is like a double-edged sword in the body. Insufficient NO causes hypertension and atherosclerosis, while an overproduction of NO may foster inflammation and cause heart infarction and shock. In addition, growing evidences have shown that oxidative stress plays pivotal roles in the initiation and progression of CVDs. This chapter will discuss in detail the roles NO plays in the cardiovascular system under both physiological and pathological conditions. We will focus on: (1) the molecular mechanism of cardiovascular contraction, (2) NO/Ca2+-induced muscle relaxation, (3) NO-related structural change in blood vessels, and (4) redox balance in the cardiovascular system. The relationships between these molecular mechanisms and the characteristics of CVDs will be highlighted.