Pęczkowski Grzegorz

Prof. Pęczkowski Grzegorz

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2018 in Water
Verified
Journal Article
Open access
PDF file
PGPęczkowski Grzegorz
Pęczkowski Grzegorz
TKTomasz Kowalczyk
Tomasz Kowalczyk
KSKatarzyna Szawernoga
Katarzyna Szawernoga
WOWojciech Orzepowski
Wojciech Orzepowski
RŻRomuald Żmuda
Romuald Żmuda
RPRyszard Pokładek
Ryszard Pokładek
Within the scope of the conducted experiment the authors analysed the efficiency of runoff reduction by the system of extensive type green roofs. The observations were based on storm events in the area of Lower Silesia at the Agro and Hydrometeorology Station Wrocław-Swojec. The authors analysed the thickness of plant substrate, and also estimated the quality of runoff waters under the conditions of periodic atmospheric deposition. Also considered were such indicators as electrolytic conductivity, N, NO3−, NO2−, NH4+, P, PO43−. The experiment included roof substrates designed in two variants, with known hydraulic and physical properties of the soil material. The analysis was performed for models with vegetation layer based on pumice and zelolite, covered with five plant species from the sedum family. The modelling of the hydraulic properties was conducted with variably saturated medium, using the Hydrus 1D software. The performance of systems with primary layer thickness of 11 cm and 9, 8, 7, 6 and 5 cm was estimated. The designed models reduced the average peak flows to 89%, and in addition they caused a delay in the initiation of the runoff which was dependent on the intensity and distribution of rainfalls in time, and on the initial moisture of the profiles. Simulations, performed for variable substrate thickness, permit the conclusion that in the case of thin-layer profiles (5 cm), the relative retention index was decidedly lower and amounted to 35.9% for the substrate with zeolite (originally 60.6%) and 41% for the substrate with pumice (originally 65.7%). In the case of total nitrogen and phosphates, statistical analysis revealed significant differences (p < 0.05) in relation to specific concentrations in the rainwater and in the control surface. The total nitrogen in the runoff from the green roof was nearly twice as high as that in the rainwater and amounted to, on average, 8.3 mg L−1.

11 June 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
PGPęczkowski Grzegorz
Pęczkowski Grzegorz
KSKatarzyna Szawernoga
Katarzyna Szawernoga
TKTomasz Kowalczyk
Tomasz Kowalczyk
WOWojciech Orzepowski
Wojciech Orzepowski
RPRyszard Pokładek
Ryszard Pokładek
Green architecture, including green roofs, can limit the effects of urbanization. Green roofs soften the thermal effect in urban conditions, especially considering the significant increase in the European and global population and that a significant share of the age group, mainly the elderly is exposed to diseases caused by high temperatures. We studied runoff and the quality of water from green roof systems in Lower Silesia, within the area of the Agro and Hydrometeorology Station Wrocław-Swojec, in the years 2012–2016. In the study, two systems with a vegetation layer based on light expanded clay aggregate and perlite were analyzed. The studies were based on the assessment of peak flow reduction, rainwater volume preservation and peak wave reduction. The calculated maximum retention performance indicator, relative to rainfall, for perlite surfaces was up to 65%, and in relation to the control surface up to 49%. In addition, the quality of water from runoff was estimated in the conditions of annual atmospheric deposition, taking into account such indicators as electrolytic conductivity; the content of N, NO3, NO2, NH4, P, PO4; and the content of metals, Cu, Zn, Pb and Cd. The load of total nitrogen exceeded the values of concentration in rainwater and amounted to 7.17 and 13.01 mg∙L−1 for leca and perlite, respectively. In the case of the metal content, significantly higher concentrations of copper and zinc from green surfaces were observed in relation to precipitation. For surfaces with perlite, these were 320 mg∙L−1 and 241 mg∙L−1, respectively, with rainwater concentrations of 50 and 31 mg∙L−1.

18 October 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KWKarol Wolski
Karol Wolski
JMJoanna Markowska
Joanna Markowska
ARAdam Radkowski
Adam Radkowski
MBMarek Brennensthul
Marek Brennensthul
Łukasz SobolŁukasz Sobol
Łukasz Sobol
Karen KhachatryanKaren Khachatryan
Karen Khachatryan
The selection of grass mixtures with appropriate visual and functional parameters for sowing football fields is a key element in shaping the sports infrastructure, ensuring the spectacularity of a match and comfort for players. The aim of the research was to investigate the properties of lawn grass mixtures and their suitability for football pitches. The experiment was conducted at the Toya Golf & Country Club (51° 20′ E, 17° 07′ N), Wrocław, Poland, between 2007 and 2009. 12 grass mixtures were selected, mainly based on red fescue, Kentucky bluegrass, and perennial ryegrass. The assessment was carried out using a nine-point scale, according to the Plant Variety Office methodology for crops and turf grass. Six features of sports turf were studied: appearance, density, colour, leaf fineness, overwintering, and susceptibility to disease and they significantly varied, depending on the grass mixture and the year of research. Our study showed that mixtures based on the dominance of meadow grass were characterized by higher values of the general visual aspect, colour and slenderness of the leaf blade and these based on the dominance of perennial ryegrass and co-dominance of perennial ryegrass and meadow grass were the most useful in terms of wintering, resistance to diseases and sodding.

6 June 2021 in Water
Verified
Journal Article
Open access
PDF file
AWAmadeusz Walczak
Amadeusz Walczak
ASAgnieszka Szypłowska
Agnieszka Szypłowska
GJGrzegorz Janik
Grzegorz Janik
PGPęczkowski Grzegorz
Pęczkowski Grzegorz
The study was aimed at the determination of the dynamics of spatial distribution of moisture front, caused by pointwise application of water under conditions of high pressure. This was effected through a series of simulations of water injection to a porous material with particle size distribution corresponding to that of sand. The study was composed of six independent experimental series in which the sand monolith was supplied with water doses of 250, 500, 750, 1000, 1250, and 1500 cm3 under pressure (4 bar). At the same time, measurements of volumetric moisture were conducted with the use of TDR sensors, which were positioned within the soil in a regular grid pattern. It was demonstrated that the primary cause of water movement at the moment of injection is the pressure potential gradient of water molecules. The spatial reach of moisture change in relation to the injected water dose was also defined. It was also observed that in the course of water injection there is a risk of disturbing the structure of the porous material. The correctness of the adopted method was verified through the calculation of the water balance.

26 December 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
PGPęczkowski Grzegorz
Pęczkowski Grzegorz
RWRafał Wójcik
Rafał Wójcik
WOWojciech Orzepowski
Wojciech Orzepowski
Green facades, commonly referred to as vertical plant systems, offer sustainable solutions. They improve the energy efficiency of buildings, reduce energy consumption, and positively impact the microclimate both at the microscale and at the urban level. Their ability to regulate temperature and improve thermal comfort, including mitigating the heat island effect, makes them a valuable element of sustainable architectural design. They also contribute to reduced energy consumption, reduced noise, mitigation of air pollution, and aesthetic and wind protection. The main goal of the study was to analyse the cooling effectiveness of green walls in a transitional temperate climate zone. The study was conducted on two experimental models located on the campus of the Wrocław University of Environmental and Life Sciences and at the Research and Educational Station in a suburban area. Both locations had different characteristics: the former contained urban development, while the latter contained open and sparsely developed areas. On warm and sunny days, the cooling effects of the systems were observed independently for both locations and their exposures. For data acquisition at a distance of 5 cm from the plants, a higher data concentration and a lower variability in the mean temperature drop were observed. In the same group, on sunny days, the cooling effect averaged 4–7 °C and depended on the location. On cloudy days, the mean maximum cooling in this group did not exceed 4 °C.

17 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
PGPęczkowski Grzegorz
Pęczkowski Grzegorz
RWRafal Wojcik
Rafal Wojcik
WOWojciech Orzepowski
Wojciech Orzepowski
Environmental awareness and sustainable development in the context of energy secu-rity, including reduced energy consumption, increasingly require the introduction of innovative solutions in urban areas. These will primarily be systems based on natural architecture, particularly green facades and green roofs. In the near future, they will undoubtedly constitute an integral element of most architectural solutions and are al-ready a standard within global development strategies. Society faces the priority of achieving carbon neutrality, reducing the consumption of natural resources, and minimising the carbon footprint. This paper analyses the temperature around the canopy and the rear surfaces of two experimental models of green facades located on the campus of the University of Life Sciences in the centre of Wroclaw and at the Re-search and Educational Station of the same institution located in the suburban area of Swojec, southern Poland. In both cases, the locations can be classified within the same region, a transitional temperate climate zone. The purpose of the study was to evaluate the thermal effect of two locations with different characteristics, determined in the first case by dense urban development, and in the second by open and sparsely devel-oped areas. Analysis of average temperature reductions for warm and sunny days re-vealed a significant cooling effect. This effect was observed for green surfaces, regard-less of the location and display of the model. For the variant at a distance of 5 cm from the plants, a higher data concentration and a lower variability were recorded. In the same group, on sunny days, the cooling effect, depending on the location, was 4-7° C. On cloudy days, average maximum cooling in this group did not exceed 4° C. It should be emphasised that future research should focus on other elements of these systems, employ a multidisciplinary approach, and additionally have a significant impact on the urban microclimate and the immediate surroundings of the facades.