Ben Delaney

Ben Delaney


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2024 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
KMK. Mongey
K. Mongey
SLS. J. J. de Lange
S. J. J. de Lange
RBR. Brady
R. Brady
DHD. J. Hemminga
D. J. Hemminga
BDBen Delaney
Ben Delaney
John SheilJohn Sheil
John Sheil
Experimentally generated and simulated soft x-ray plasma images and spectra from 1064 nm-driven laser-produced plasmas from slab tin are presented. Produced are small, micrometer-scale emission volumes with principle imaged emission lying between 1.2 and 2.5 nm. Experimental images of the soft x-ray emission of these plasmas are generated using a pinhole imaging system, which enables spatial characterization of the plasmas, and a simple transmission grating spectrometer with a 100 nm pitch grating is used to facilitate the spectral characterization of these plasmas. Plasmas are simulated under similar experimental conditions to those used with the single-fluid, single-temperature radiation-hydrodynamics code RALEF-2D. Coupling the simulation output with optical modeling methods demonstrates its promise as a capability for modeling the spatial and spectral behavior of soft x-ray-emitting tin plasmas at such scales and laser energies.

23 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BDBen Delaney
Ben Delaney
SBSjors Buntinx
Sjors Buntinx
DEDon M.J. van Elst
Don M.J. van Elst
AKAnne van Klinken
Anne van Klinken
RVRené P. J. van Veldhoven
René P. J. van Veldhoven
AFAndrea Fiore
Andrea Fiore
Measuring the composition of materials at a distance is a key requirement in industrial process monitoring, recycling, precision agriculture, and environmental monitoring. Spectral imaging in the visible or near-infrared (NIR) spectral bands provides a potential solution by combining spatial and spectral information, and its application has seen significant growth over recent decades. Low-cost solutions for visible multispectral imaging (MSI) have been developed due to the widespread availability of silicon detectors, which are sensitive in this spectral region. In contrast, development in the NIR has been slower, primarily due to the high cost of indium gallium arsenide (InGaAs) detector arrays required for imaging. This work aims to bridge this gap by introducing a standoff material sensing concept which combines spatial and spectral resolution without the hardware requirements of traditional spectral imaging systems. It combines spatial imaging in the visible range with a CMOS camera and NIR spectral measurement at selected points of the scene using an NIR spectral sensor. This allows the chemical characterization of different objects of interest in a scene without acquiring a full spectral image. We showcase its application in plastic classification, a key functionality in sorting and recycling systems. The system demonstrated the capability to classify visually identical plastics of different types in a standoff measurement configuration and to produce spectral measurements at up to 100 points in a scene.

1 March 2025 in Review of Scientific Instruments
Verified
Journal Article
Open access
KMK. Mongey
K. Mongey
RBR. Brady
R. Brady
TMT. Miyazaki
T. Miyazaki
ESEmma Sokell
Emma Sokell
BDBen Delaney
Ben Delaney
FOFergal O'Reilly
Fergal O'Reilly
Spectroscopy is a fundamental tool in characterizing laser-produced plasmas. In this article, the design and deployment of a centimeter-scale soft x-ray transmission grating spectrometer that utilizes a commercial Complementary Metal–Oxide–Semiconductor (CMOS) detector are discussed in detail. This spectrometer was designed to facilitate the spectral characterization of micrometer-scale soft x-ray emitting laser-produced plasmas with a short working path length. A free-standing silicon nitride transmission grating with a pitch of 100 nm, a working width of 5 μm, and an effective length of 3 mm is utilized in conjunction with precision scale machining and 3D printing techniques to construct the device. With the spectrometer, spectral images are produced, showing emission features in the 1–3 nm region from multiple atomic targets. We present these results compared to spectra recorded with a higher-resolution spectrometer and also investigate the utility of photon counting based spectroscopy, whereby the energy dependent response of the CMOS detector itself is utilized. The spectrometer impulse response function is modeled using the Fresnel diffraction integral, with a fixed grating aperture. Simulated spectra are produced using FLYCHK, a dimensionless collisional radiative model for the laser-produced plasma, which serves as a model input to test the veracity of the optical modeling. In addition to developing a compact and affordable spectrometer, a primary motivation behind this device was to record spectral data from laser plasma emission in high pressure helium environments, and data are presented on this.

22 May 2022
Verified
Conference Paper
Closed access
KMK. M. Mongey
K. M. Mongey
RBR. Brady
R. Brady
ESEmma Sokell
Emma Sokell
BDBen Delaney
Ben Delaney
FOF. O'REilly
F. O'REilly
Laser plasmas can produce a high flux of soft x-ray radiation from a small volume, making them ideal for illumination for applications such as in EUV nano-lithography [1] and in cell imaging via soft x-ray tomography [2] .

14 October 2025 in Journal of Physics D: Applied Physics
Verified
Journal Article
Open access
KMKevin Mongey
Kevin Mongey
RBRuairí Brady
Ruairí Brady
MOMateusz Olszewksi
Mateusz Olszewksi
BDBen Delaney
Ben Delaney
ESEmma Sokell
Emma Sokell
FOFergal O'Reilly
Fergal O'Reilly
In this study, we report advances in experimental imaging and diffraction modeling methods to measure and accurately infer laser-produced plasma (LPP) emission spatial dimensions as small as 5 µ m in the soft x-ray (SXR) region between 1–3 nm. Small-scale SXR emission volumes were generated from the irradiation of molybdenum with a high peak power Nd:YAG laser. Computational fitting methods coupled with direct diffraction models enabled precise measurement of the plasma size by removing blurring inherent to the imaging system. The techniques demonstrated here can be applied to research in determining the SXR emission size of LPPs, which is essential for calculating LPP source radiance; this is a key parameter in imaging, spectroscopy and patterning applications where LPP SXR emission is of significant utility and interest.

19 March 2024 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
NWNicholas Wong
Nicholas Wong
JHJason Howard
Jason Howard
BDBen Delaney
Ben Delaney
ESEmma Sokell
Emma Sokell
PBPaola Bolognesi
Paola Bolognesi
LALorenzo Avaldi
Lorenzo Avaldi
Equal energy sharing PEPECO measurements at 10 and 20 eV yielded photodouble ionization triple-differential cross sections for C6H6 and C5H5S, which were characterized by a new multi-Gaussian fit method based on He to allow a molecular comparison.