In this paper, we propose a multi-perspective ultrasound imaging technology with the cylindrical motion of four piezoelectric micromachined ultrasonic transducer (PMUT) rotatable linear arrays. The transducer is configured in a cross shape vertically on the circle with the length of the arrays parallel to the z axis, roughly perpendicular to the chest wall. The transducers surrounded the breast, which achieves non-invasive detection. The electric rotary table drives the PMUT to perform cylindrical scanning. A breast model with a 2 cm mass in the center and six 1-cm superficial masses were used for the experimental analysis. The detection was carried out in a water tank and the working temperature was constant at 32 °C. The breast volume data were acquired by rotating the probe 90° with a 2° interval, which were 256 × 180 A-scan lines. The optimized segmented dynamic focusing technology was used to improve the image quality and data reconstruction was performed. A total of 256 A-scan lines at a constant angle were recombined and 180 A-scan lines were recombined according to the nth element as a dataset, respectively. Combined with ultrasound imaging algorithms, multi-perspective ultrasound imaging was realized including vertical slices, horizontal slices and 3D imaging. The seven masses were detected and the absolute error of the size was approximately 1 mm where even the image of the injection pinhole could be seen. Furthermore, the breast boundary could be seen clearly from the chest wall to the nipple, so the location of the masses was easier to confirm. Therefore, the validity and feasibility of the data reconstruction method and imaging algorithm were verified. It will be beneficial for doctors to be able to comprehensively observe the pathological tissue.
In order to better detect information about a mass in breast tissue, an ultrasound tomography algorithm based on adaptive time gain compensation (TGC) was designed. Field II was utilized to automatically evaluate the phantom attenuation coefficient and compensate for the attenuated image. The image reconstruction algorithm process is presented here. Furthermore, the experimental setup with the cylindrical motion of a piezoelectric micromachined ultrasonic transducer (PMUT) linear array was used to detect the mass in the breast model. The attenuation coefficient was evaluated by using the spectral cross-correlation method. According to the acquired attenuation coefficients, TGC compensates for the pulse-echo signal, and the horizontal slice image was reconstructed using the tomography algorithm. The experimental results show that this algorithm can evaluate the attenuation coefficient of the breast model and improve the ability to detect an internal mass. At the same time, the realization of attenuation compensation with software is beneficial to the development of portable medical equipment.
14 February 2025 in International Journal of Engineering and Technology Innovation
The study aims to develop a piezoelectric micromachined ultrasonic transducer (PMUT) with high transmission capability to achieve greater detection depth. The structural design of the sensing cell based on aluminum nitride (AlN) thin film is provided, and a mathematical theoretical model is derived. Static pressure, static displacement, vibration modes, resonant frequency, sensitivity, and acoustic impedance are analyzed using the finite element analysis. The areas of the upper and lower electrodes and the thicknesses of the piezoelectric and vibrating films are optimized. Simulation results indicate that when the ratio of the upper and lower electrodes of the sensing cells is 0.7, the electromechanical coupling efficiency of the transducer is enhanced, and its transmission performance is further improved. Mainly the first-order resonant frequency of PMUT is 7.62 MHz, with a sensitivity of -198 dB and an effective electromechanical coupling coefficient of 10.2%, meeting the design requirements for breast cancer detection.