Purpose: To evaluate the effect of cone-beam computed tomography (CBCT) on radiation exposure, procedure time, and contrast media (CM) use in prostatic artery embolization (PAE). Materials and Methods: Seventy-eight patients were enrolled in this retrospective, single-center study. All patients received PAE without (group A; n = 39) or with (group B; n = 39) CBCT. Total dose-area product (DAPtotal; Gycm2), total entrance skin dose (ESDtotal; mGy), and total effective dose (EDtotal; mSv) were primary outcomes. Number of digital subtraction angiography (DSA) series, CM use, fluoroscopy time, and procedure time were secondary outcomes. PAE in group A was performed by a single radiologist with 15 years experience, PAE in group B was conducted by four radiologists with 4 to 6 years experience. Results: For groups A vs. B, respectively, median (IQR): DAPtotal 236.94 (186.7) vs. 281.20 (214.47) Gycm2(p = 0.345); EDtotal 25.82 (20.35) vs. 39.84 (23.75) mSv (p = < 0.001); ESDtotal 2833 (2278) vs. 2563 (3040) mGy(p = 0.818); number of DSA series 25 (15) vs. 23 (10)(p = 0.164); CM use 65 (30) vs. 114 (40) mL(p = < 0.001); fluoroscopy time 23 (20) vs. 28 (25) min(p = 0.265), and procedure time 70 (40) vs.120 (40) min(p = < 0.001). Bilateral PAE was achieved in 33/39 (84.6%) group A and 32/39 (82.05%) group B(p = 0.761), all other patients received unilateral PAE. There were no significant differences between clinical parameters and origins of the prostatic arteries (PA) (p = 0.206–1.00). Conclusion: Operators with extensive expertise on PAE may not benefit from addition of CBCT to DSA runs, whereas for operators with less expertise, CBCT when used alongside with DSA runs increased the overall radiation exposure.
Background: It is essential to avoid admission of patients with undetected corona virus disease 2019 (COVID-19) to hospitals’ general wards. Even repeated negative reverse transcription polymerase chain reaction (RT-PCR) results do not rule-out COVID-19 with certainty. The study aimed to evaluate a rule-out strategy for COVID-19 using chest computed tomography (CT) in adults being admitted to the emergency department and suspected of COVID-19. Methods: In this prospective, single centre, diagnostic accuracy cohort study, consecutive adults (≥ 18 years) presenting with symptoms consistent with COVID-19 or previous contact to infected individuals, admitted to the emergency department and supposed to be referred to general ward were included in March and April 2020. All participants underwent low-dose chest CT. RT-PCR- and specific antibody tests were used as reference standard. Main outcome measures were sensitivity and specificity of chest CT. Predictive values were calculated based on the theorem of Bayes using Fagan’s nomogram. Results: Of 165 participants (56.4% male, 71 ± 16 years) included in the study, the diagnosis of COVID-19 was confirmed with RT-PCR and AB tests in 13 participants (prevalence 7.9%). Sensitivity and specificity of chest CT were 84.6% (95% confidence interval [CI], 54.6–98.1) and 94.7% (95% CI, 89.9–97.7), respectively. Positive and negative likelihood ratio of chest CT were 16.1 (95% CI, 7.9–32.8) and 0.16 (95% CI, 0.05–0.58) and positive and negative predictive value were 57.9% (95% CI, 40.3–73.7) and 98.6% (95% CI, 95.3–99.6), respectively. Conclusion: At a low prevalence of COVID-19, chest CT could be used as a complement to repeated RT-PCR testing for early COVID-19 exclusion in adults with suspected infection before referral to hospital’s general wards. Trial registration ClinicalTrials.gov: NCT04357938 April 22, 2020.
Background/Objectives: This study aimed to develop a reliable scoring system combining clinical and radiological parameters to distinguish atypical lipomatous tumours (ALTs) from lipomas, improving diagnostic accuracy and reducing expensive molecular pathology testing. Methods: A retrospective analysis of 188 patients who underwent surgery for lipomatous tumours was conducted. Patient data, including medical history, pathology, and MRI imaging results, were reviewed. Four predictive models were developed using various clinical and imaging parameters, including age, tumour size, location, and MRI characteristics (homogeneity, contrast enhancement). Statistical analysis, including ROC curve analysis and logistic regression, was performed to assess the accuracy of these models. Results: The highest predictive accuracy was achieved with Model 1, which included seven parameters, yielding an AUC of 0.952. This model achieved a sensitivity of 96.4% and a negative predictive value (NPV) of 97.2%. Reducing the number of parameters lowered the accuracy, with contrast enhancement playing a significant role in Model 1. A risk calculator based on the optimal model was developed, offering an effective tool for clinical use that can be provided. Notably, 21 out of 37 ALTs lacked atypia and would have been missed without molecular testing. Conclusions: The developed scoring system, based on clinical and imaging parameters, accurately distinguishes ALTs from lipomas, offering a practical alternative to molecular pathology testing. This multi-parameter approach significantly improves diagnostic reliability, reducing the risk of misclassification and false negatives, while also potentially lowering healthcare costs.
Zusammenfassung: Ein 79-jähriger Patient wird aufgrund einer rezidivierenden Serratia-marcescens-Bakteriämie stationär behandelt. Es konnten eine Infektion der Elektroden des implantierbaren Kardioverter-Defibrillator (ICD) mit septischen pulmonalen Embolien und eine Spondylodiszitis diagnostiziert werden. Zusätzlich zur Antibiotikatherapie erfolgte die komplette Extraktion des ICD-Systems. Bei Patienten mit kardialen elektronischen Implantaten (CIED) und einer nicht hinreichend erklärbaren bzw. rezidivierend auftretenden Bakteriämie, unabhängig davon, um welchen Erreger es sich handelt, muss immer eine CIED-assoziierte Infektion ausgeschlossen werden.
Transarterial radioembolization generally results in low radiation exposure for medical staff; 166 Ho-poly-L-lactic acid microspheres led to the highest body doses, while 90 Y-resin microspheres generated the highest hand doses, with interventional radiologists receiving the highest overall doses.