Background: Proximal Roux-en-Y gastric bypass is commonly used to manage obesity, performed using laparoscopic or robot-assisted minimally invasive surgery. As the prevalence of robotic bariatric surgery increases, further data is required to justify its use. Methods: This was a large, retrospective analysis of prospectively recorded data for Roux-en-Y gastric bypass (RYGB) procedures performed using laparoscopic (LRYGB) or robotic (RRYGB; da Vinci Xi system, Intuitive Surgical Sàrl) surgery between January 2016 and March 2019. The surgical techniques did not differ apart from different trocar placements. Data collected included patient characteristics before and after RYGB, operative outcomes and complications. Results: In total, 114 RRYGB and 108 LRYGB primary surgeries were performed. There were no significant differences between the groups, apart from a significantly shorter duration of surgery (116.9 vs. 128.9 min, respectively), lower C-reactive protein values at days 1 (31.1 vs. 44.1 mg/l) and 2 (50.3 vs. 77.8 mg/l) after the intervention, and overall complication rate (4.4 vs. 12.0%, Clavien-Dindo classification II-V) with RRYGB compared with LRYGB. There was a lower hemoglobin value in the postoperative course after RRYGB (12.1 vs. 12.6 g/dl, day 2). Conclusions: In our experience, robotic RYGB has proven to be safe and efficient, with a shorter duration of surgery and lower rate of complications than laparoscopic RYGB. RRYGB is easier to learn and seems safer in less experienced centers. Increasing experience with the robotic system can reduce the duration of surgery over time. Further studies with higher evidence level are necessary to confirm our results.
Recent developments in robotic surgery have led to an increasing number of robot-assisted hepatobiliary procedures. However, a limitation of robotic surgery is the missing haptic feedback. The fluorescent dye indocyanine green (ICG) may help in this context, which accumulates in hepatocellular cancers and around hepatic metastasis. ICG accumulation may be visualized by a near-infrared camera integrated into some robotic systems, helping to perform surgery more accurately. We aimed to test the feasibility of preoperative ICG application and its intraoperative use in patients suffering from hepatocellular carcinoma and metastasis of colorectal cancer, but also of other origins. In a single-arm, single-center feasibility study, we tested preoperative ICG application and its intraoperative use in patients undergoing robot-assisted hepatic resections. Twenty patients were included in the final analysis. ICG staining helped in most cases by detecting a clear lesion or additional metastases or when performing an R0 resection. However, it has limitations if applied too late before surgery and in patients suffering from severe liver cirrhosis. ICG staining may serve as a beneficial intraoperative aid in patients undergoing robot-assisted hepatic surgery. Dose and time of application and standardized fluorescence intensity need to be further determined.
Introduction: Revisional procedures in bariatric surgery are regarded as technically more demanding and riskier than primary interventions. While the use of the surgical robot has not yet proven to be advantageous in primary bariatric interventions, the question remains whether its use is justified for more complex revisional procedures. Objective: To show that revisional bariatric surgery can be performed safely using the da Vinci® Xi surgical system. Methods: We performed a retrospective analysis of prospectively recorded data for revisional bariatric procedures between January 2016 and November 2019. Results: Of 78 revision operations, four (5.1%) were performed by open surgery, 30 (38.5%) by laparoscopic surgery, and 44 (56.4%) by robotic surgery. A comparative analysis of robotic (n = 41) versus laparoscopic (n = 18) revisional Roux-en-Y gastric bypasses (rRYGB) revealed significant differences favoring the robotic approach for operative time (130.7 vs. 167.6 min), C-reactive protein values at days 1 (27.9 vs. 49.1 mg/L) and 2 (48.2 vs. 83.6 mg/L) after surgery, and length of stay (4.9 vs. 6.2 days). Lower complication rates (Clavien-Dindo II–V) were found after rRRYGB (7.3 vs. 22.2%, not significant). Conclusions: Revisional bariatric surgery using a robotic system is safe. The operative time performing rRRYGB is significantly shorter than rLRYGB in our experience. Otherwise, results were largely comparable. Due to different indications, different index operations and a wide range of revisional procedures, further studies are necessary to confirm these results.
Introduction: Robotic-assisted liver surgery (RALS) with its known limitations is gaining more importance. The fluorescent dye, indocyanine green (ICG), is a way to overcome some of these limitations. It accumulates in or around hepatic masses. The integrated near-infrared cameras help to visualize this accumulation. We aimed to compare the influence of ICG staining on the surgical and oncological outcomes in patients undergoing RALS. Material and Methods: Patients who underwent RALS between 2014 and 2021 at the Department of General Surgery at the University Hospital Schleswig-Holstein, Campus Kiel, were included. In 2019, ICG-supported RALS was introduced. Results: Fifty-four patients were included, with twenty-eight patients (50.9%) receiving preoperative ICG. Hepatocellular carcinoma (32.1%) was the main entity resected, followed by the metastasis of colorectal cancers (17%) and focal nodular hyperplasia (15.1%). ICG staining worked for different tumor entities, but diffuse staining was noted in patients with liver cirrhosis. However, ICG-supported RALS lasted shorter (142.7 ± 61.8 min vs. 246.4 ± 98.6 min, p < 0.001), tumors resected in the ICG cohort were significantly smaller (27.1 ± 25.0 mm vs. 47.6 ± 35.2 mm, p = 0.021) and more R0 resections were achieved by ICG-supported RALS (96.3% vs. 80.8%, p = 0.075). Conclusions: ICG-supported RALS achieve surgically and oncologically safe results, while overcoming the limitations of RALS.
Introduction: For over two decades, abdominal surgical procedures have been safely performed robotically. After the first patent expiration, alternative robotic systems entered the market. The Dexter Robotic System™ is a small-format, modular, and robotic platform consisting of a surgeon’s console, two patient carts with instrument arms, and one endoscope arm. We report our initial experiences with Dexter since its installation at our visceral surgery department. Methods: The system and surgical setup are described. Demographic and perioperative data of all operated patients as well as the system docking times were analyzed. Results: From 56 procedures performed with Dexter, the most common ones included cholecystectomy (n = 15), inguinal hernia repair (TAPP; unilateral n = 15; bilateral n = 3), and right oncologic hemicolectomy (n = 15). The median docking time was 6 min (2–16 min) and was reduced to 4 min in the last tertile of procedures performed. Conclusions: In our experience, Dexter can be implemented without any major challenges, and visceral surgical procedures of simple to medium complexity can be performed safely. The simplicity and accessibility of the system along with the ease of switching between robotics and laparoscopy could be particularly suitable for beginners in robotic surgery
Surgical robots are increasingly being used in bariatric surgery. While several studies describe the safety of using barbed sutures in laparoscopic gastric bypass surgery, no reports are available for robotic bariatric procedures. The aim of our article is to determine whether barbed sutures can be used safely in robotic Roux-en-Y bypass (RYGB) surgery. This was a single-center, single-surgeon case series of RYGB procedures using the da Vinci® Xi Surgical System (Intuitive Surgery, Sunnyvale, CA, USA) in combination with the use of barbed sutures (Stratafix, Ethicon, Johnson & Johnson, Cincinnati, OH, USA). Fifty robotic proximal and distal RYGB surgeries were performed. A linear stapled, side-to-side gastrojejunostomy was carried out, whereby the enterotomy was completed with a running resorbable unidirectional barbed suture, Stratafix 2–0. In one case after robotic proximal RYGB, revision surgery was required due to omentum necrosis. Another patient was readmitted due to gastrointestinal bleeding from anastomosis. No anastomotic insufficiencies, no stenoses, or higher-grade complications according to Clavien-Dindo 4a-5 were found. We found that the use of self-fixing barbed sutures in robotic RYGB is safe. The self-fixing suture enables the robotic surgeon to perform a simple continuous suture without the need for recurrent retraction. Although we are the first to report this procedure, we had a low number of cases and no control group; thus, further studies with a higher level of evidence are required.