Techniques based on plasmonic resonance can provide label-free, signal enhanced, and real-time sensing means for bioparticles and bioprocesses at the molecular level. With the development in nanofabrication and material science, plasmonics based on synthesized nanoparticles and manufactured nano-patterns in thin films have been prosperously explored. In this short review, resonance modes, materials, and hybrid functions by simultaneously using electrical conductivity for plasmonic biosensing techniques are exclusively reviewed for designs containing nanovoids in thin films. This type of plasmonic biosensors provide prominent potential to achieve integrated lab-on-a-chip which is capable of transporting and detecting minute of multiple bio-analytes with extremely high sensitivity, selectivity, multi-channel and dynamic monitoring for the next generation of point-of-care devices.
Lidar techniques have been widely employed for atmospheric remote sensing during past decades. However, an important drawback of the traditional atmospheric pulsed lidar technique is the large blind range, typically hundreds of meters, due to incomplete overlap between the transmitter and the receiver, etc. The large blind range prevents the successful retrieval of the near-ground aerosol profile, which is of great significance for both meteorological studies and environmental monitoring. In this work, we have demonstrated a new experimental approach to calibrate the overlap factor of the Mie-scattering pulsed lidar system by employing a collocated Scheimpflug lidar (SLidar) system. A calibration method of the overlap factor has been proposed and evaluated with lidar data measured in different ranges. The overlap factor, experimentally determined by the collocated SLidar system, has also been validated through horizontal comparison measurements. It has been found out that the median overlap factor evaluated by the proposed method agreed very well with the overlap factor obtained by the linear fitting approach with the assumption of homogeneous atmospheric conditions, and the discrepancy was generally less than 10%. Meanwhile, simultaneous measurements employing the SLidar system and the pulsed lidar system have been carried out to extend the measurement range of lidar techniques by gluing the lidar curves measured by the two systems. The profile of the aerosol extinction coefficient from the near surface at around 90 m up to 28 km can be well resolved in a slant measurement geometry during nighttime. This work has demonstrated a great potential of employing the SLidar technique for the calibration of the overlap factor and the extension of the measurement range for pulsed lidar techniques.
Endovascular glue embolization is a minimally invasive technique used to selectively reduce or block the blood supply to specific targeted vessels. Cyanoacrylate glues, mixed with radiopaque iodized oil, have been widely used for vascular embolization owing to their rapid polymerization rate, good penetration ability and low tissue toxicity. Nevertheless, in clinical practice, the selection of the glue–oil proportion and the manual injection process of mixtures are mostly based on empirical knowledge of operators, as the crucial physicochemical effect of polymerization kinetics has rarely been quantitatively investigated. In this study, the Raman spectroscopy is used for studying the polymerization kinetics of n-butyl-cyanoacrylate-based glues mixed with an iodized oil. To simulate the polymerization process during embolization, glue–oil mixtures upon contact with a protein ionic solution mimicking blood plasma are manually constructed and their polymerization kinetics are systematically characterized by Raman spectroscopy. The results demonstrate the feasibility of Raman spectroscopy in the characterization of polymerization kinetics of cyanoacrylate-based embolic glues. The polymerization process of cyanoacrylate-based mixtures consists of a fast polymerization phase followed by a slow phase. The propagation velocity and polymerization time primarily depend on the glue concentrations. The commonly used 50% mixture polymerizes 1 mm over ∼21.8 s, while it takes ∼51 min to extend to 5 mm. The results provide essential information for interventional radiologists to help them understand the polymerization kinetics of embolic glues and thus regulate the polymerization rate for effective embolization.
10 May 2011 in Applied Biochemistry and Biotechnology
Nonlinear optical (NLO) imaging has emerged as a promising plant cell imaging technique due to its large optical penetration, inherent 3D spatial resolution, and reduced photodamage; exogenous nanoprobes are usually needed for nonsignal target cell analysis. Here, we report in vivo, simultaneous 3D labeling and imaging of potato cell structures using plasmonic nanoprobe-assisted multimodal NLO microscopy. Experimental results show that the complete cell structure can be imaged via the combination of second-harmonic generation (SHG) and two-photon luminescence (TPL) when noble metal silver or gold ions are added. In contrast, without the noble metal ion solution, no NLO signals from the cell wall were acquired. The mechanism can be attributed to noble metal nanoprobes with strong nonlinear optical responses formed along the cell walls via a femtosecond laser scan. During the SHG-TPL imaging process, noble metal ions that crossed the cell wall were rapidly reduced to plasmonic nanoparticles with the fs laser and selectively anchored onto both sides of the cell wall, thereby leading to simultaneous 3D labeling and imaging of the potato cells. Compared with the traditional labeling technique that needs in vitro nanoprobe fabrication and cell labeling, our approach allows for one-step, in vivo labeling of plant cells, thus providing a rapid, cost-effective method for cellular structure construction and imaging.
Laser triangulation is essential for industrial thickness measurement but faces challenges such as high noise sensitivity and non-uniform reflectivity. To address these issues, this paper presents a high-precision dual-path method based on a complementary optics–algorithm design that combines an oblique-incidence optical configuration with a spatial-topological constrained grayscale centroid method (STC-GCM). The dual-path configuration satisfies the Scheimpflug condition and is designed to enhance signal intensity, imaging quality, and stripe continuity. The STC-GCM integrates Otsu thresholding and morphological denoising with a constraint mechanism based on topological connectivity and geometric validity, thereby converting improved optical observability into robust valid-stripe selection. Comparisons show that the algorithm improves center-extraction accuracy by approximately 34% relative to the conventional GCM and achieves approximately 4× the computational efficiency of the Steger algorithm. Experiments over a 1.0–5.0 mm range yielded a maximum absolute error of 2.3 µm, a linearity of 0.058% FS, and a mean repeatability standard deviation of 0.90 µm. This technique provides a practical approach for high-precision industrial thickness monitoring under the evaluated conditions.