This study presents real-time measurements of particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2) concentrations across five university indoor environments with varying occupancy levels and natural ventilation conditions. CO2 concentrations frequently exceeded the 1000 ppm guideline, with peak values reaching 3018 ppm and 2715 ppm in lecture spaces, whereas one workshop environment maintained levels well below limits (mean = 668 ppm). PM concentrations varied widely: PM10 reached 541.5 µg/m3 in a carpeted amphitheater, significantly surpassing the 50 µg/m3 legal daily limit, while a well-ventilated classroom exhibited lower levels despite moderate occupancy (PM10 max = 116.9 µg/m3). Elevated PM values were strongly associated with flooring type and occupant movement, not just activity type. Notably, window ventilation during breaks reduced CO2 concentrations by up to 305 ppm (p < 1 × 10−47) and PM10 by over 20% in rooms with favorable layouts. These findings highlight the importance of ventilation strategy, spatial orientation, and surface materials in shaping indoor air quality. The study emphasizes the need for targeted, non-invasive interventions to reduce pollutant exposure in historic university buildings where mechanical ventilation upgrades are often restricted.
The objective of this research is to analyze metal elements, such as Na (sodium), Mg (magnesium), Al (aluminum), Si (silicon), Pb (lead), K (potassium), Ca (calcium), and Fe (iron), found in dust particles within two distinct areas from which the samplings were taken. The first sampling was taken from the road verge of a highly trafficked road section, while the second sampling was taken from a residential garden area 90 m away from the road. Several metal elements were detected with a high difference in Si, which presented higher concentrations in the dust samples from the road verge area. Pb has only been detected in the samples taken from the road verge, which could be explained by residual remnants from old lead gasoline and wheel weights. Additionally, during the same investigation, airborne particulate matter (PM) concentrations were measured in comparison between the road verge and the garden area; this presented a substantial difference in the concentration levels, suggesting that dense vegetation is protecting and blocking a majority of airborne PM. A literature highlight of the health effects of different metal elements and PM concentrations is presented.
The objective of this research is to analyze metal elements like Na (sodium), Mg (magnesium), Al (aluminum), Si (silicon), Pb (lead), K (potassium), Ca (calcium), and Fe (iron) found in dust particles within two distinct areas from which the sampling has been done. First sampling was taken from the road verge of a highly trafficked road section, while the second sampling was done in a residential garden area 90 m away from the road. Several metal elements have been detected, with a high difference for Silicon Si, which present higher concentrations in the dust sampled from the road verge area. Pb has only been detected in the samples taken from the road verge, which could be explained by residual remnants from old lead gasoline, and wheel weights. Additionally, airborne particulate matter (PM) concentrations have been measured, during the same episode, in comparison between the road verge and the garden area, presenting a substantial difference in the concentration levels, deducing that dense vegetation is protecting and blocking a majority of airborne PM. A literature highlight of health effects of different metal elements and PM concentrations is presented.
Indoor air quality (IAQ) research remains divided across three separate streams: sensor-based monitoring, CFD simulation, and occupant-centered evaluation. This separation limits how readily technical measurements translate into actionable building guidance. To assess this divide, a systematic review and critical synthesis of 192 peer-reviewed studies was conducted, with each study categorized by which domain or domains it addressed. This categorization shows that fewer than 8% integrate all three—a figure derived directly from the classification rather than asserted independently of it. Accuracy itself proves uneven: under specific operational and environmental conditions reported in the literature, low-cost particulate sensors have been found to underestimate PM2.5 by as much as 50%, and wall-mounted placements often misrepresent breathing-zone exposure. These limitations carry into simulation, where the k–ω SST model persists as the practical standard despite Large Eddy Simulation’s superior accuracy at two orders of magnitude greater computational cost. Building these findings, the review proposes a Tripartite IAQ Assessment Framework (TIAF) synchronizing sensor protocols, simulation outputs, and occupant surveys, addressing a regulatory tendency to privilege instrument metrics over lived experience. Implications extend to IAQ-responsive digital twins and post-pandemic governance, resolving the “stuffy-but-clean” paradox through validated, cross-domain integration.