Venera-Stanca Nicolici

Mrs. Venera-Stanca Nicolici

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AHMED ADJALAHMED ADJAL
AHMED ADJAL
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
BBBalogh Balogh
Balogh Balogh
Ioana IonelIoana Ionel
Ioana Ionel
Indoor air quality (IAQ) research remains divided across three separate streams: sensor-based monitoring, CFD simulation, and occupant-centered evaluation. This separation limits how readily technical measurements translate into actionable building guidance. To assess this divide, a systematic review and critical synthesis of 192 peer-reviewed studies was conducted, with each study categorized by which domain or domains it addressed. This categorization shows that fewer than 8% integrate all three—a figure derived directly from the classification rather than asserted independently of it. Accuracy itself proves uneven: under specific operational and environmental conditions reported in the literature, low-cost particulate sensors have been found to underestimate PM2.5 by as much as 50%, and wall-mounted placements often misrepresent breathing-zone exposure. These limitations carry into simulation, where the k–ω SST model persists as the practical standard despite Large Eddy Simulation’s superior accuracy at two orders of magnitude greater computational cost. Building these findings, the review proposes a Tripartite IAQ Assessment Framework (TIAF) synchronizing sensor protocols, simulation outputs, and occupant surveys, addressing a regulatory tendency to privilege instrument metrics over lived experience. Implications extend to IAQ-responsive digital twins and post-pandemic governance, resolving the “stuffy-but-clean” paradox through validated, cross-domain integration.

4 February 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
DMDan-Marius Mustață
Dan-Marius Mustață
Ioana IonelIoana Ionel
Ioana Ionel
DBDaniel Bisorca
Daniel Bisorca
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
Roadside public transport stops represent localized air pollution hotspots where short-term exposure may differ substantially from levels reported by urban background monitoring. This study investigates the application of low-cost air quality sensors for long-term characterization of particulate matter and gaseous pollutants in a traffic-dominated urban microenvironment. The novelty of this work lies in the combined use of collocated low-cost sensors, energy-independent solar-powered deployment, height-resolved placement representative of different breathing zones, and integrated statistical and predictive analysis to resolve exposure-relevant pollutant dynamics at a single transport stop. Hourly concentrations of particulate matter (PM) PM1, PM2.5, PM10, nitrogen dioxide (NO2), and ozone (O3) were measured over one year at a roadside transport stop adjacent to a four-lane urban road carrying approximately 30,000 vehicles per day. Measurements were obtained using two collocated low-cost sensor units based on optical particle sensing for particulate matter and electrochemical sensing for gases, together with concurrent meteorological observations. Strong agreement between the two particulate matter sensors supported the use of averaged concentrations. Mean PM2.5 concentrations were substantially higher in winter (32.4 µg/m3) than in summer (10.4 µg/m3), indicating pronounced seasonal variability. PM1 and PM2.5 exhibited closely aligned temporal patterns, while PM10 showed greater variability. NO2 displayed sharp diurnal peaks associated with traffic activity, whereas O3 exhibited opposing seasonal and diurnal behavior and was negatively correlated with both PM2.5 (r = −0.32) and NO2 (r = −0.29). One-hour-ahead predictive models incorporating meteorological and temporal variables achieved coefficients of determination up to 0.84. The results demonstrate that energy-independent low-cost sensor systems can robustly capture temporal patterns, pollutant interactions, and short-term predictability in localized roadside environments relevant to exposure assessment.

12 October 2026 in Nitrogen
Verified
Journal Article
Open access
PDF file
AHMED ADJALAHMED ADJAL
AHMED ADJAL
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
Ioana IonelIoana Ionel
Ioana Ionel
Energy codes require envelope airtightness that pushes natural air exchange below 0.30–0.35 h−1, turning the dwelling into a partly closed compartment of the reactive nitrogen cycle. This review synthesizes 82 studies on reactive nitrogen (NO, NO2, HONO) in energy-efficient buildings. The novelty of this review consists of three elements. First, it organizes the evidence around a mass balance for reactive nitrogen rather than around building typologies. Second, it uses the Damköhler number as a single criterion for when indoor transport and chemistry must be solved together. Third, it derives, from published parameters, the ventilation rates a cooking event would require. Emission factors for unvented gas cooking converge on 29.3–42.5 ng NOx J−1 expressed as NO2-equivalent, of which primary NO2 accounts for 7.8–9.1 ng J−1, with NO exceeding NO2 by 1.8–2.7 times. NO penetrates the envelope unimpeded; NO2 penetration is 0.72 ± 0.06 with a humidity-dependent loss rate of 0.27 ± 0.12 h−1. Reactive nitrogen cannot be treated as a passive scalar in quiescent zones of airtight dwellings, where air speeds fall below about 0.03–0.06 m s−1 at 20–40 ppb indoor ozone, whereas the bulk of a mixed room remains in the passive-scalar regime. Using the primary NO2 emission factor, the mass balance shows that keeping the hourly mean below the 1 h guideline during a 30 min cooking event would require 2.9–18.4 h−1, one to two orders of magnitude beyond z ventilation. NO2 removal is governed jointly by ventilation and surface uptake, so carbon dioxide is an unsuitable surrogate for demand-controlled ventilation.

1 June 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
AHMED ADJALAHMED ADJAL
AHMED ADJAL
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
EGEugenia Grecu
Eugenia Grecu
Ioana IonelIoana Ionel
Ioana Ionel
This research paper addresses the persistent problem of environmental opacity in sustainable debt markets, exposing a structural flaw that incremental regulation alone cannot remedy. This study advances a radical, physics-grounded solution that fundamentally transforms environmental reporting from voluntary self-disclosure to instrumentally verified, quantum-limited measurement. The method integrates three mutually reinforcing analytical frameworks: the design of Quantum-Verified Green Bonds (QVGBs), the application of cryptographic quantum key distribution (QKD), and the formal apparatus of financial contract theory. The principal conceptual innovation resides in a three-tiered architectural structure—physical, cyber–physical, and financial—that collectively shifts the epistemological foundation of sustainable finance from institutional norms and managerial discretion to the immutable constraints of physical laws. By deploying nitrogen-vacancy (NV) centers in diamond as primary sensing arrays at industrial emission points, this system achieves environmental parameter estimation bounded by the Cramér–Rao quantum limits, a precision ceiling governed by Quantum Fisher Information, not corporate policy. This architecture acquires high-fidelity, real-time data on CO2 and CH4 flux densities, transforming atmospheric pollutant concentrations into physically attested, contractually actionable financial variables. A QKD layer further leverages the no-cloning theorem to render any upstream data manipulation physically self-revealing through statistically detectable elevations in the Quantum Bit Error Rate (QBER). The central contribution of this work lies in the algorithmic coupling of bond coupon structures to these quantum-verified state variables, enforced via smart contracts, thereby converting “environmental misinformation” from a viable managerial strategy into a strictly dominated equilibrium outcome. These findings carry substantial implications for bridging the “trust gap” in green financial markets, a gap sustained by chronically undervalued transition risks and deficient accountability mechanisms in air quality and carbon reporting. The QVGB framework stabilizes green asset prices by subordinating capital allocation decisions to physical constraints rather than political or institutional ones, thereby establishing a new ontological baseline for the global sustainable debt market.

26 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
Ioana IonelIoana Ionel
Ioana Ionel
DBDaniel Bisorca
Daniel Bisorca
Indoor climbing gyms are high-occupancy settings, yet integrated indoor air quality (IAQ) studies that analyze objective exposure and occupant perception remain scarce. The novelty consists of combining user perception with multi-zone, high-resolution IAQ measurements. We investigated a climbing gym in Romania to (i) quantify particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2), (ii) compare natural and mechanical ventilation under real operating conditions with per capita normalization, (iii) relate exposure to occupancy and user perception, and (iv) coupling continuous optical monitoring with 24 h gravimetric and morphological/chemical analyses (scanning electron microscopy, confocal microscopy, X-ray fluorescence, and inductively coupled plasma mass spectrometry). The gravimetric 24 h reference measurements (EN 12341:2014) showed that daily means for PM2.5 and PM10 were 1.9–2.0× and 2.3–2.8× higher than the WHO guideline values, which confirms persistent daily particulate loads. Mechanical ventilation reduced coarse PM and CO2, but absolute PM remained elevated and fine fractions persisted. CO2 revealed a near-uniform vertical mixing, confirming dilution but indicating that CO2 is not a surrogate for particulate exposure. Survey responses from occupants revealed a gap between perception and reality: most of the users rated IAQ as good despite high PM. This study is among the few integrations of perception of IAQ for climbing gyms and the first comprehensive assessment in Romania, providing evidence-based recommendations on ventilation and filtration upgrades, chalk use management, and dust-reservoir control, thus creating sparkling interest for IAQ researchers, building services engineers, sports facilities operators, and policymakers.

Verified
Journal Article
Open access
PDF file
VNVenera-Stanca Nicolici
Venera-Stanca Nicolici
AHMED ADJALAHMED ADJAL
AHMED ADJAL
Ioana IonelIoana Ionel
Ioana Ionel
EGEugenia Grecu
Eugenia Grecu
In the last 10 years, the global green bond market has reached an estimated value of USD 6.8 trillion. However, credibility concerns persist due to greenwashing risks and issues regarding the reporting system. The current measurement, reporting, and verification systems (MRV) have high uncertainty levels of 10–30%, and so they contribute to information asymmetries and fuel investor skepticism when allocating capital to green bond instruments. The scope of this study is to develop an integrated management approach that links air quality and greenhouse gas monitoring with financial incentives throughout the lifecycle of green bonds. The central contribution is a four-phase lifecycle model covering issuance, allocation, monitoring, and impact reporting, which systematically identifies where greenwashing risks and verification gaps arise across the investment cycle. Methodologically, the study combines qualitative content analysis, a novel Disclosure Quality Score (DQS) instrument, based on the Regulation (EU) 2023/2631, four documentary case studies, and an advanced verification framework. The content analysis shows that regulatory and market-performance studies dominate the literature, while integrated lifecycle verification frameworks remain less explored. The DQS uses eight indicators, applied to a matched sample of green bonds, in accordance with the European Green Bond Standard (EuGB) and the ICMA Green Bond Principles (GBP). The results demonstrate that bonds issued under the EuGB present higher disclosure quality (mean DQS = 15.4/16) compared to GBP-aligned bonds (mean DQS = 11.4/16). Case studies show strong issuance-stage disclosure, but weak post-issuance verification. The framework enables lifecycle-wide accountability by reducing information asymmetry. The proposed lifecycle framework and DQS instrument offer a replicable model for improving disclosure quality and ESG performance standards, with direct implications for sustainable investment screening and ESG fund selection. Overall, the findings show that improving green bond credibility requires moving beyond issuance-focused disclosure toward lifecycle-wide verification.