Mohammed Alqahtani

Dr. Mohammed Alqahtani

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2018 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
MAMohammed Alqahtani
Mohammed Alqahtani
AAAbdullah Saeed Alayad
Abdullah Saeed Alayad
AAAbdulmonem Alshihri
Abdulmonem Alshihri
FCFernanda Oliveira Bello Correa
Fernanda Oliveira Bello Correa
ZAZohaib Akram
Zohaib Akram

21 January 2020 in Medicina
Verified
Journal Article
Open access
PDF file
MAMohammed Alqahtani
Mohammed Alqahtani
SHSatheesh Haralur
Satheesh Haralur
Background and Objectives: Fractured acrylic denture base is a common occurrence in clinical practice. The effective denture repair procedure is cost-effective, time conserving, and results in lesser time without denture for the patient. Along with various reinforcements and surface modifications; different acrylic resins are investigated in improving the flexural strength of the fractured site. The aim of this study was to evaluate the flexural strength of a polymethyl methacrylate (PMMA) denture base repaired with heat-polymerized (HPA), auto-polymerized (APA) and light-polymerized acrylic (LPA) resins after thermocycling. Materials and Methods: Forty rectangular shaped (50 mm × 25 mm × 3 mm) PMMA specimens were fabricated. Group 1 specimens (n = 10) were kept as controls and the remaining 30 samples were sectioned at the center with a repair site dimension of 3 mm. The samples from three groups (n = 10) were repaired with HPA, APA, and LPA resins, respectively. The specimens were thermocycled for 5000 cycles and subjected to a three-point flexural test. The maximum load required to fracture the specimens was recorded, and further analyzed with ANOVA and the Games-Howell Post hoc test at the significance level p = 0.05. Results: The average maximum load and flexural strength of the control group was 173.60 N and 13.02 Mpa and corresponding values for denture repaired with HPA was 87.36 N and 6.55 Mpa. The corresponding values for APA resin and LPA resins were 62.94 N, 57.51 N, and 4.72 Mpa, 4.06 Mpa, respectively. Conclusions: The PMMA specimens repaired with HPA resins resulted in a significantly higher load to fracture compared to APA resin and LPA resin.

1 July 2017 in The Saudi Dental Journal
Verified
Journal Article
Open access
HTHuda Tulbah
Huda Tulbah
EAEman AlHamdan
Eman AlHamdan
MAMohammed Alqahtani
Mohammed Alqahtani
AAAsma AlShahrani
Asma AlShahrani
MAMona AlShaye
Mona AlShaye
Read the latest articles of The Saudi Dental Journal at ScienceDirect.com, Elsevier’s leading platform of peer-reviewed scholarly literature

28 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
RARuwaida Z Alshali
Ruwaida Z Alshali
MAMohammed Alqahtani
Mohammed Alqahtani
The aim of this study is to assess the effect of different bleaching agents on microhardness and color of CAD/CAM ceramics including IPS e.max CAD (lithium disilicate), VITA ENAMIC (polymer-infiltrated ceramic), and Celtra Duo CAD (zirconia-reinforced lithium silicate). Materials’ samples were divided into three groups (n = 10) and each received a different bleaching treatment; 20% carbamide peroxide, 35% carbamide peroxide, and 40% hydrogen peroxide. A fourth group was stored in water acting as a control. Vickers microhardness and spectrophotometric color measurements were taken at baseline and after bleaching. IPS e.max CAD showed a significant reduction (about 14%), while VITA ENAMIC showed a significant increase (about 78%) in microhardness after bleaching (p ˂ 0.001). Celtra Duo CAD did not demonstrate a significant change in microhardness (p ≥ 0.609). The color difference (ΔEab) after bleaching was 0.29 (±0.08), 2.84 (±0.64), and 1.99 (±0.37) for IPS e.max CAD, VITA ENAMIC, and Celtra Duo CAD, respectively. It could be concluded that the effect of bleaching on color and microhardness was mainly material-dependent. Bleaching significantly affected the microhardness of IPS e.max CAD and VITA ENAMIC. The color difference was within the clinically imperceptible range for IPS e.max CAD, while VITA ENAMIC and Celtra Duo CAD demonstrated perceptible color change.

1 January 2019 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
SHSyed Rashid Habib
Syed Rashid Habib
AAAbdul Sadekh Ansari
Abdul Sadekh Ansari
MAMohammed Alqahtani
Mohammed Alqahtani
IAIbrahim F Alshiddi
Ibrahim F Alshiddi
AAAbdulaziz Alqahtani
Abdulaziz Alqahtani
SHSyed Hammad Hassan
Syed Hammad Hassan
The objective of the study was to analyze the surface area (SA) of the wear caused by simulated chewing on human enamel and opposing restorative material, namely: composite resin (CR), porcelain fused to metal (PFM), lithium disilicate (LD), or monolithic zirconia (MZr). Forty-eight premolars were selected as enamel specimens and divided randomly into 4 groups (n = 48; n =12) used as antagonists in chewing simulation (250,000 loading cycles) against one of the four selected test materials. Enamel and material specimens were scanned and evaluated under digital microscope, and wear SA (mm2) were recorded. Descriptive statistics, paired t-test, one-way ANOVA, and post-hoc Tukey-HSD tests were used for statistics (p < 0.05). The smallest and largest SA were exhibited by enamel against LD (0.80 mm2) and PFM (1.74 mm2), respectively. PFM (3.48 mm2) showed the largest SA and CR (2.28 mm2) showed the smallest SA. Paired t-test for SA values showed significant difference (p < 0.05) in all wear comparisons between materials and enamel antagonists. The wear of materials were greater than that of their respective enamel antagonists (p < 0.05). One-way ANOVA of the logarithmic means of wear SA revealed significant differences (P<0.05). Post-hoc Tukey test revealed significance for PFM (p < 0.05) with other materials. Wear of all test materials was greater compared to the wear of enamel antagonists. PFM and LD caused the largest and the smallest enamel wear, respectively. CR, LD, and MZr are more resistant than PFM to wear after simulated chewing against enamel.

1 October 2019 in The Saudi Dental Journal
Verified
Journal Article
Open access
MAMohammed Alqahtani
Mohammed Alqahtani
MAMohammed Alrefaie
Mohammed Alrefaie
AAAbdulaziz Altamimi
Abdulaziz Altamimi
IAIbrahim Aljowyed
Ibrahim Aljowyed
AAAbdulaziz AlQahtani
Abdulaziz AlQahtani
SHSyed Rashid Habib
Syed Rashid Habib
Read the latest articles of The Saudi Dental Journal at ScienceDirect.com, Elsevier’s leading platform of peer-reviewed scholarly literature