Gülşah Yenier Yurdagüven

Dr. Gülşah Yenier Yurdagüven

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2024 in Journal of Dentistry
Verified
Journal Article
Closed access
GYGülşah Yenier Yurdagüven
Gülşah Yenier Yurdagüven
EÇElif Çiftçioğlu
Elif Çiftçioğlu
FKFatma Şehnaz Kazokoğlu
Fatma Şehnaz Kazokoğlu
MKMehmet Baybora Kayahan
Mehmet Baybora Kayahan

9 August 2023 in Australian Endodontic Journal
Verified
Journal Article
Closed access
GYGülşah Yenier Yurdagüven
Gülşah Yenier Yurdagüven
VIVasfiye Isik
Vasfiye Isik
EÇElif Çiftçioğlu
Elif Çiftçioğlu
HUHaşmet Ulukapı
Haşmet Ulukapı
MKMehmet Baybora Kayahan
Mehmet Baybora Kayahan

21 August 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
GYGülşah Yenier Yurdagüven
Gülşah Yenier Yurdagüven
Biomimetic restorative dentistry aims to preserve tooth structure and achieve optimal aesthetic harmony with surrounding dentition. The principles and protocols associated with biomimetic restorative dentistry are designed to enhance the longevity of the restoration. The use of flowable CRs is increasingly common; however, the effect of viscosity on the discoloration has not been clearly established. This in vitro study aimed to assess the color stability of flowable CRs with varying viscosities following immersion in common staining solutions and subsequent repolishing. A total of 250 disc-shaped specimens (8 mm × 2 mm) were prepared from five CRs with different viscosity profiles: high-viscosity (Spectra STHV, Dentsply, Milford, DE, USA), medium-viscosity (Estelite Universal Flow Medium, Tokuyama Dental Co., Tokyo, Japan), bulk-fill (Estelite Bulk-Fill Flow, Tokuyama Dental Co., Tokyo, Japan; SDR Plus, Dentsply, Milford, DE, USA), and packable (Estelite Posterior, Tokuyama Dental Co., Tokyo, Japan). After polymerization and baseline color measurements, specimens were immersed in coffee, tea, cola, red wine, or distilled water for 144 h. Color values were recorded before and after staining, and again following repolishing. Color changes (ΔE1, ΔE2, ΔE3) were calculated using the CIE Lab system and statistically analyzed via two-way ANOVA and Tukey HSD (α = 0.05). Both the CR type and the staining solution substantially affected the color change. SDR Plus exhibited the highest ΔE values. Red wine caused the most discoloration. Repolishing enhanced color in selected groups.

25 November 2025 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
EBElif Turkes Basaran
Elif Turkes Basaran
BDBurcu Dikici
Burcu Dikici
GYGülşah Yenier Yurdagüven
Gülşah Yenier Yurdagüven
HYHaktan Yurdagüven
Haktan Yurdagüven
Aim: In response to the nationwide measures due to the COVID-19 pandemic, face-to-face preclinical dental education transitioned to a hybrid format. This survey aimed to assess the impact of hybrid education on dental students’ transition to clinical practice and to evaluate the efficacy and sustainability of preclinical education delivered in a hybrid model. Methods: The multi-centered questionnaire survey was e-mailed to students who received preclinical education in dentistry faculties from 2018 to 2020 and subsequently proceeded to clinical education. Students who received preclinical education in face-to-face and hybrid formats were included. The survey examined how preclinical education affects restorative clinical skills and students’ perceptions. It compared students with different levels of preclinical education using descriptive statistics and the Mann-Whitney U test for quantitative analysis ( p < 0.05). Results: Analysis of responses from 341 participants revealed that students who received face-to-face preclinical education exhibited greater confidence in performing restorative procedures than students educated in a hybrid format. Nonetheless, both groups demonstrated a high level of self-assurance. Conclusion: This study highlights the challenges faced by students in hybrid learning and provides strategies to overcome them. With proper adjustments, hybrid learning can become a reliable and flexible component of dental education, maintaining continuity and quality even in challenging circumstances. The study also informs future curriculum planning by emphasizing the importance of preparedness for distance-based learning, flexibility in clinical scheduling, and early identification of gaps in clinical skill development.

22 October 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
GYGülşah Yenier Yurdagüven
Gülşah Yenier Yurdagüven
IDIşıl Doğruer
Işıl Doğruer
MÇMelek Çam
Melek Çam
HUHaşmet Ulukapı
Haşmet Ulukapı
AAAyşe Arzu Aykor
Ayşe Arzu Aykor
Comparative analyses of different adhesive systems have illustrated that variations in the content can substantially influence the effectiveness of bonding. While in vitro studies provide essential insights, it is imperative that clinical recommendations derive from randomized clinical trials to ensure their reliability and validity. This double-blind, split-mouth, randomized clinical trial was conducted to assess the performance of various universal adhesives over a 24-month period, with a specific emphasis on monomer type, HEMA content, and solvent type, using the selective enamel etch approach in non-carious cervical lesion (NCCL) restorations. Thirty-two participants with two-hundred-fifty-six NCCLs were assigned to the two groups (n = 128): G-Premio Bond (GPB; GC) and Single Bond Universal (SBU; 3 M ESPE). The same composite resin (Essentia, GC) was used. Restorations were assessed at baseline, 12-month, and 24-month using the Revised FDI criteria by two blinded calibrated examiners. Statistical analysis included Fisher’s Exact Chi-Square test, Continuity (Yates) Correction, and McNemar tests (p < 0.05). The 24-month success rate was 98.2%, with the loss of retention in four restorations—two from SBU and two from GPB. Throughout all evaluation periods, no significant differences were identified between the adhesives regarding any criteria (p > 0.05). Both adhesives exhibited a significant decline in marginal adaptation at both the 12-month and 24-month evaluations, as well as an increase in marginal staining at the 24-month interval (p < 0.05). Notwithstanding the observed decrease in marginal adaptation after 24 months, all restorations remained clinically acceptable and were classified as clinically satisfactory. A clinical analysis over a 24-month period demonstrated that variations in the composition of universal adhesives—specifically concerning monomer types, HEMA content, and solvent type—did not significantly affect the performance of NCCL restorations. Notably, all retained restorations met clinical acceptability standards. The clinical trial was registered on 13/01/2021 at https//clinicaltrials.gov with the ID (NCT04707898).

15 June 2023 in Selcuk Dental Journal
Verified
Journal Article
Open access
PDF file
GYGülşah Yenier Yurdagüven
Gülşah Yenier Yurdagüven
BTBerna Tarim
Berna Tarim
Background: The aim of this study was to evaluate the effect of different adhesive applications on dentine microtensile bond strength (μTBS) in simplified adhesive systems. Methods: Seventy-two extracted non-carious human third molars were randomly divided 18 groups (n=4). Dentin surfaces were polished with #600-grit silicon-carbide paper. Two-step etch&rinse Adper Single Bond2 [SB](3M ESPE) and one-step self-etch Clearfil S3 Bond [S3](Kuraray) were tested, two-step self-etch Clearfil SE Bond [SE](Kuraray) was used as control. The tested adhesives were applied according to the manufacturer’s instructions [MI] or with 2% Chlorhexidine [CHX] or double application of the adhesive [DA] or with hydrophobic resin layer [HR]. Composite build-up (Filtek Ultimate,3MESPE) was restored incrementally and stored in distilled water (24h/37°C). Teeth were sectioned as 1mm2 resin-dentin sticks (Isomet) and subjected to μTBS test (Bisco) immediately [24h] or after six months of water-storage [6M] (Crosshead speed:0.5mm/min.) Data were analyzed by Three-way ANOVA and post-hoc Tukey’s tests (p<0.05). Results: The dentine µTBS was significantly influenced by the adhesive system (p:0.001), adhesive applications (p:0.001), and storage time (p:0.001). The highest μTBS was found in SE-MI (p0.05). The µTBS of all groups decreased significantly at 6M (p<0.01). HR and DA showed significantly higher μTBS than CHX and MI (p0.05). When adhesives were compared, DA and HR were significantly higher μTBS in S3 (p<0.01). Conclusion: HR and DA improved the μTBS while no significant enhancement was observed by CHX. Keywords: Chlorhexidine, dental adhesives, dentin, dentin bonding agents, longevity. Amaç: Bu çalışmanın amacı, basitleştirilmiş adeziv sistemlerde farklı adeziv uygulama tekniklerinin dentine olan mikrogerilim bağlanma dayanımına (μTBS) etkisini değerlendirmektir. Gereç ve Yöntemler: Yetmiş iki adet çekilmiş çürüksüz insan üçüncü büyük azı dişi rastgele 18 gruba ayrıldı (n=4). Dentin yüzeyleri #600-grit silikon-karbit kağıt ile cilalandı. Kontrol grubunu Clearfil SE Bond [SE] (Kuraray), deney gruplarını iki aşamalı etch&rinse Adper Single Bond2 [SB] (3M ESPE) ve tek aşamalı self-etch Clearfil S3 Bond [S3] (Kuraray) oluşturdu. Test edilen adezivler, üretici firmanın talimatları [Kontrol] veya %2 Klorheksidin ile [CHX], veya iki kat adeziv uygulaması ile [x2K] veya ilave hidrofobik reçine tabaka [HR] ile uygulandı. Kompozit blok (Filtek Ultimate, 3M ESPE) tabaklama yöntemiyle oluşturuldu ve distile suda bekletildi (24 saat/37°C). 1mm2 reçine-dentin çubuklarına (Isomet) ayrılarak hemen [24sa] veya 37°C’de altı ay [6.ay] suda bekletildikten sonra μTBS testine tabi tutuldu (Bisco) (Çapraz kafa hızı 0.5 mm/dk). Veriler Three-way ANOVA ve post-hoc Tukey testleri kullanılarak analiz edildi (p0.05). Tüm grupların 6.ay µTBS değerleri anlamlı düzeyde azalmıştır (p<0.01). HR ve x2K, CHX ve Kontrol gruplarından anlamlı düzeyde daha yüksek μTBS sergilerken (p0.05). Adezivler karşılaştırıldığında 6.ayda, x2K ve HR uygulaması S3’de anlamlı düzeyde yüksektir (p<0.01). Sonuçlar: HR ve x2K dentine μTBS değerlerini arttırırken; CHX ile anlamlı düzeyde bir artış gözlenmemiştir. Anahtar kelimeler: Dental adezivler, dentin, dentin yapıştırma ajanları, klorheksidin, uzun ömürlülük