Background/Objectives: This study aimed to investigate the microtensile bond strength (µTBS) of composite-based (Cerasmart), polymer-infiltrated (Vita Enamic), and feldspathic (Cerec) CAD/CAM blocks luted to dentin using a dual-cure resin cement (LinkForce), as well as micro-hybrid (G-aenial) and flowable composites (G-aenial Universal Flo), and evaluate the microhardness (HV) of luting materials through the CAD/CAM blocks. Methods: Cerasmart, Enamic, and Cerec were luted to dentin using three luting materials; LinkForce, G-aenial, and Universal Flo (n = 5). For HV, 117 disk-shaped specimens from LinkForce, G-aenial, and Universal Flo (n = 13) were polymerized through 3 mm thick CAD/CAM. Thirty-nine light-cured specimens without CAD/CAM were used as control. Following 24 h storage, the µTBS and HV were evaluated. Data were analyzed using the two-way ANOVA and post hoc Tukey tests (p < 0.05). Results: The µTBS to dentin and HV were significantly influenced by the type of luting material and CAD/CAM material. With all the CAD/CAM materials, LinkForce and Universal Flo exhibited a significantly similar µTBS to that of dentin (p > 0.05). Compared with the control group, all the HV values of the luting materials decreased significantly (p < 0.05). Conclusions: Heavily filled flowable composites exhibit a bonding effectiveness similar to that of dual-cure resin cements. All the luting materials showed similar HV when polymerized through the polymer-infiltrated CAD/CAM material.
This study assessed the repair shear bond strength (SBS; MPa) and surface roughness (Ra; μm) of aged hybrid ceramic (Cerasmart270, GC) and nano-hybrid ceramic (Grandio Blocs, Voco) CAD/CAM blocks after different surface pretreatment methods. In this study, 2 mm thick Cerasmart270 and Grandio Blocs were cut into slabs (Isomet; n = 80 per group). Following aging for six months, the specimens in each CAD/CAM material were randomly divided into four groups (n: 20 each) according to the surface pretreatments: control (no pretreatment), Er:YAG laser, sandblasting, and bur grinding. A total of 10 specimens in each CAD/CAM material pretreatment group were used for Ra evaluation (Perthometer Mahr), while the other 10 were for SBS. After the application of a silane primer (G-Multi Primer, GC) and universal adhesive (G2-Bond, GC), composite build-ups (Filtek Z250; 3MESPE) were performed for the SBS evaluation. After storage in distilled water for 24 h, SBS was evaluated with a universal testing machine (Instron). SBS and Ra data were analyzed with two-way ANOVA and Tukey’s post hoc tests (p < 0.05). SBS was significantly affected by the surface pretreatment methods (p = 0.0001) and by the types of CAD/CAM material (p = 0.005). Bur grinding showed the highest SBS for both CAD/CAM materials, while the control groups yielded significantly lower SBS than bur grinding and sandblasting (p < 0.05). Er:YAG lasers did not significantly enhance the SBS compared to the control group. Sandblasting presented significantly higher SBS than lasers only in Grandio Blocs (p < 0.05). The surface pretreatment methods significantly influenced Ra (p = 0.0001); however, no significant interaction was found between the types of CAD/CAM material and the surface pretreatments (p > 0.05). Control groups exhibited, significantly, the lowest Ra for both materials (p = 0.0001), while no significant differences were observed between the other pretreatment methods. Bur grinding was identified as the most effective pretreatment method for repairing hybrid ceramic CAD/CAM materials.
26 October 2021 in Journal of Adhesion Science and Technology
This in-vitro study aimed to evaluate the micro-tensile bond strength (μTBS; MPa) of a highly-filled flowable composite (G-aenial Universal Flo; GC, UF), a micro-hybrid composite (G-aenial; GC, C) and dual-cure resin cement (Linkforce; GC, LF) used as luting materials to composite (Cerasmart; GC, CS), polymer infiltrated-ceramic (Enamic; Vita, VE) and feldspathic ceramic (Cerec; Sirona, CE) CAD/CAM blocks with and without additional universal adhesive (G-Premio Bond; GC, UA) application. CAD/CAM blocks (n:3) from each material were cut into slabs of 4 mm thickness and were divided into two groups according to the presence or absence of UA application. Slabs from VE, CS and CE were luted together with UF, C and LF. Following storage in distilled water at 37 °C for 24 h, µTBS (n:24 with UA; n:24 without UA, Instron Inc) was evaluated and analyzed with three-way ANOVA and post hoc Tukey’s tests (p < 0.05). µTBS was significantly influenced by the type of CAD/CAM material (p = 0.0001), resin luting material (p = 0.0001) and UA application (p = 0.0001). VE + UF resulted in significantly the highest µTBS with and without UA (p < 0.05). UF and LF exhibited similar µTBS to CS and CE with and without UA (p > 0.05), while UA significantly increased bonding in the VE + C, CS + C and CE + C groups (p < 0.05). The bonding performance of the highly filled flowable composite to VE, CS and CE was similar or significantly higher than that of the micro-hybrid composite and dual-cure resin cement with and without UA application. Additional UA application improved bonding of the micro-hybrid composite to all CAD/CAM materials.
Aim: In response to the nationwide measures due to the COVID-19 pandemic, face-to-face preclinical dental education transitioned to a hybrid format. This survey aimed to assess the impact of hybrid education on dental students’ transition to clinical practice and to evaluate the efficacy and sustainability of preclinical education delivered in a hybrid model. Methods: The multi-centered questionnaire survey was e-mailed to students who received preclinical education in dentistry faculties from 2018 to 2020 and subsequently proceeded to clinical education. Students who received preclinical education in face-to-face and hybrid formats were included. The survey examined how preclinical education affects restorative clinical skills and students’ perceptions. It compared students with different levels of preclinical education using descriptive statistics and the Mann-Whitney U test for quantitative analysis ( p < 0.05). Results: Analysis of responses from 341 participants revealed that students who received face-to-face preclinical education exhibited greater confidence in performing restorative procedures than students educated in a hybrid format. Nonetheless, both groups demonstrated a high level of self-assurance. Conclusion: This study highlights the challenges faced by students in hybrid learning and provides strategies to overcome them. With proper adjustments, hybrid learning can become a reliable and flexible component of dental education, maintaining continuity and quality even in challenging circumstances. The study also informs future curriculum planning by emphasizing the importance of preparedness for distance-based learning, flexibility in clinical scheduling, and early identification of gaps in clinical skill development.
This study aimed to evaluate the effect of preheating on the push-out bond strength (PBS) and microhardness (HV) of fiber-reinforced flowable and injectable composites and to compare them with dual-cure resin–cement for post cementation. Fifty premolars were endodontically treated, and post spaces were prepared. Specimens were divided into five groups (n = 10) based on the resin luting material. After adhesive application, fiber posts were luted with dual-cure resin–cement (LinkForce), fiber-reinforced flowable composites (EverX Flow; non-heated/preheated), and injectable composites (G-aenial Universal Injectable; non-heated/preheated). After 24 h, roots were sectioned (coronal, middle, apical) for PBS testing (Instron). For HV, 10 specimens per resin luting material were prepared, and top/bottom microhardness was measured to assess the depth of cure. Data were analyzed with two-way ANOVA and post hoc Tukey tests (p < 0.05). Both types of resin luting material and preheating significantly affected PBS and HV (p = 0.0001). Preheated EverX Flow showed significantly higher PBS and HV than LinkForce, while G-aenial Injectable exhibited the lowest values (p < 0.05). Within each resin luting material, PBS significantly decreased from the coronal to the apical region (p = 0.0001). Preheated fiber-reinforced flowable composites demonstrate improved microhardness and adhesion, offering a reliable alternative to the dual-cure resin–cements for fiber post cementation.