Distribution System State Estimation (DSSE) infers the states (e.g., voltage phasors) using measurements from the electric distribution grid. As the distribution network becomes more active due to the increasing penetration of Distributed Energy Resources (DER), a deeper investigation into conventional DSSE approaches is needed. This review paper focuses on state-of-the-art techniques and challenges for DSSE in the context of emerging concepts, such as new sensor technologies, data-driven approaches, and high DER penetration.
12 October 2023 in IEEE Transactions on Sustainable Energy
The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. The results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.
The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.
In this paper, we consider the problem of optimizing voltage set points and switching status of components in direct current power networks subject to physical and security constraints. The problem is cast as a mixed-integer nonlinear programming with two sources of computational complexity: i) Non-convex power flow equations, and ii) The presence of binary variables accounting for the on/off status of network components. A strengthened second-order cone programming (SOCP) relaxation is developed to tackle the non-convexity of power flow equations, and a branch-and-bound search is employed for determining optimal network configurations. The efficacy of the proposed method in optimizing the operation while mitigating contingencies is experimentally validated in a real-time hardware-in-the-loop environment using IEEE benchmark data.
27 February 2020 in IEEE Transactions on Energy Conversion
This paper studies the acceleration of numerical simulations executed on Field-Programmable Gate Arrays (FPGAs) for electric machines presented by voltage-behind-reactance (VBR) models. In VBR models, the stator dynamics are modeled in abc coordinates, while the rotor dynamics are formulated in qd reference frame. Both induction motors and synchronous generators, operating without and with magnetic saturation, are considered. Once VBR models of these machine types are reviewed, their dynamic models are discretized using Runge-Kutta numerical routines. The detailed mapping of such discrete models to FPGA is provided using High-Level Synthesis, which directly converts untimed descriptions into VHDL or Verilog. An automated method finds the fastest FPGA architecture by finding the best set of synthesis options. Experimental results show that our FPGA-based acceleration flow leads to about 92-168 times average simulation speed-up for various machine types compared to the MATLAB simulation.
25 February 2021 in IEEE Transactions on Industrial Electronics
This article identifies the parameters of an induction machine using limited and nonintrusive observations of available input voltages, stator currents, and the rotor speed. Parameter extraction is formulated as a nonconvex estimation problem, which is then relaxed to a convex conic optimization problem. While the resulting relaxation could exhibit a satisfactory performance, there might be cases where the solution of convex relaxation fails to satisfy the dynamic equations of the machine. This is remedied through a local search approach initiated using the solution obtained from the relaxed problem. The proposed method is experimentally verified on a squirrel-cage induction machine with missing measured data. Using the measured signals as the benchmark, time-domain transients produced by the parameters estimated using the proposed method show almost 20% better match compared to time-domain transients produced by the parameters obtained via conventional testing.