Ling Yang

Dr. Ling Yang

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WWWenhua Wu
Wenhua Wu
LZLeming Zhou
Leming Zhou
YCYandong Chen
Yandong Chen
ALAn Luo
An Luo
YDYanting Dong
Yanting Dong
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Traditional grid-connected inverters (TGCI) could suffer from small-signal instability owing to the dynamic interactions among inverters and a weak grid. In this letter, the small-signal sequence impedance model of the virtual synchronous generator (VSG) is built, and the sequence impedance characteristics of the VSG and the TGCI are compared and analyzed. The sequence impedance of the TGCI is mainly capacitive in the middle-frequency area, and the impedance amplitude is quite high. By contrast, the sequence impedance of the VSG, being consistent with the grid impedance characteristics, is generally inductive, and the impedance amplitude is quite low. Based on the sequence impedance model and the Nyquist stability criterion, the influence of the grid stiffness, the number of paralleled inverters, and the phase-locked loop (PLL) bandwidth on the stability of the VSG and the TGCI systems is analyzed. The stability analysis results show that the TGCI loses stability easily, whereas the VSG still works well without PLL restrictions under an ultraweak grid or with a large number of inverters connected to the grid. Therefore, the VSG is more suitable than the TGCI for achieving high penetration of renewable energy generation in an ultraweak grid from a system stability viewpoint. Finally, the experimental results validate the sequence impedance model and the stability analysis.

8 October 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WWWenhua Wu
Wenhua Wu
MZMingmin Zhang
Mingmin Zhang
YCYandong Chen
Yandong Chen
LZLeming Zhou
Leming Zhou
ALAn Luo
An Luo
JLJinming Liu
Jinming Liu
The premise that the virtual synchronous generator (VSG) can actively support the weak grid is that the VSG can operate stably. In this paper, the small-signal sequence impedance models of the voltage-controlled VSG and the current-controlled VSG are built and the sequence impedance characteristics of these two types of VSGs are compared and analyzed. The sequence impedance of the voltage-controlled VSG, being consistent with the grid impedance characteristics, is generally inductive. By contrast, the sequence impedance of the current-controlled VSG is mainly negative impedance in the middle- and high-frequency areas and the impedance amplitude is quite low. Based on the built sequence impedance models and the impedance stability criterion, the influence of the weakness of the grid on the stability of these two types of VSG grid-connected system is analyzed. The results of stability analysis show that the current-controlled VSG is prone to instability while the voltage-controlled VSG remains stable. Therefore, the voltage-controlled VSG is more suitable than the current-controlled VSG for grid-connected renewable energy generation in an ultra-weak grid from the point of view of system stability. Finally, experiment results validate the stability analysis.

6 August 2021 in International Journal of Robust and Nonlinear Control
Verified
Journal Article
Closed access
PDF file
YWYanjiao Wang
Yanjiao Wang
LYLing Yang
Ling Yang

13 September 2023 in Energy
Verified
Journal Article
Closed access
SCSi-Zhe Chen
Si-Zhe Chen
ZLZikang Liang
Zikang Liang
HYHaoliang Yuan
Haoliang Yuan
LYLing Yang
Ling Yang
FXFangyuan Xu
Fangyuan Xu
YFYuanliang Fan
Yuanliang Fan

12 February 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
WWWenhua Wu
Wenhua Wu
YCYandong Chen
Yandong Chen
LZLeming Zhou
Leming Zhou
XZXiaoping Zhou
Xiaoping Zhou
LYLing Yang
Ling Yang
ALAn Luo
An Luo
In the maritime VSC-HVDC system supplying power to passive network on the island, the dc-side of the system is prone to oscillation and even instability, which is resulted from the negative incremental input resistance characteristic of the inverter station. Firstly, a virtual phase-lead impedance stability control strategy aiming at rectifier station is proposed. This control strategy can ef-fectively mitigate the dc-side oscillation of the VSC-HVDC system without affecting the load performance of the in-verter station. Then, the dc impedance model of the VSC-HVDC system is built, including the output impedance of the rectifier station, dc cable impedance and the input im-pedance of the inverter station. In addition, the oscillation mechanism of the VSC-HVDC system is analyzed by im-pedance-based Nyquist stability criterion. The reason why rectifier station fails to mitigate the dc-side oscillation us-ing traditional virtual resistance stability control is that the output impedance of the rectifier station exhibits negative damping characteristic outside the control bandwidth of voltage outer-loop. For this issue, the proposed control strategy can correct the output impedance of the rectifier station to exhibit positive damping characteristic outside the control bandwidth of voltage outer-loop, thus mitigating the dc-side oscillation of the VSC-HVDC system. Finally, simulation and experiment results validate the proposed control strategy and analysis.

13 February 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XZXiaoping Zhou
Xiaoping Zhou
LZLeming Zhou
Leming Zhou
YCYandong Chen
Yandong Chen
ZSZhikang Shuai
Zhikang Shuai
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
LYLing Yang
Ling Yang
In this paper, a robust grid-current-feedback reso-nance suppression (GCFRS) method for LCL-type grid-connected inverter is proposed to enhance the system damping without introducing the switching noise and eliminate the impact of control delay on system robustness against grid-impedance variation. It is composed of GCFRS method, the full duty-ratio and zero-beat-lag PWM method, and the lead-grid-current-feedback-resonance-suppression (LGCFRS) method. Firstly, the GCFRS is used to suppress the LCL-resonant peak well and avoid introducing the switching noise. Secondly, the proposed full duty-ratio and zero-beat-lag PWM method is used to elimi-nate the one-beat-lag computation delay without introducing duty cycle limitations. Moreover, it can also realize the smooth switching from positive to negative half-wave of the grid current and improve the waveform quality. Thirdly, the proposed LGCFRS is used to further minimize the control delay and make the positive or negative critical frequency of its virtual equivalent damping resistance increase above 0.5 switching frequency. Then, the system’s robustness and dynamic performance can be greatly improved. Finally, the experimental results confirm the theoreti-cal expectations and the effectiveness of the proposed method.