Li Yanlong

Mr. Li Yanlong


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2025 in Fire
Verified
Journal Article
Open access
PDF file
Jiaming ZhaoJiaming Zhao
Jiaming Zhao
CZCheng Zhang
Cheng Zhang
SFSaiya Feng
Saiya Feng
CSChen Shiyi
Chen Shiyi
GHGuanhong He
Guanhong He
WWWenbin Wei
Wenbin Wei
Metropolitan city express line tunnels are fully enclosed and often span long distances between stations, allowing multiple trains within a single interval. Traditional segmented ventilation ensures only one train per section, but ultra-long tunnels with shaftless designs introduce new challenges under fire conditions. This study investigates smoke behavior in an ultra-long inter-district tunnel during multi-train blockage scenarios. A numerical model evaluates the effects of train spacing, fire source location, and receding spacing on smoke back-layering, temperature distribution, and flow velocity. Results indicate that when train spacing exceeds 200 m and longitudinal wind speed is above 1.2 m/s, the impact of train spacing on smoke back-layering becomes negligible. Larger train spacing increases back-layering under constant wind speed, while higher wind speeds reduce it. Fire source location and evacuation spacing affect the extent and pattern of smoke spread and high-temperature zones, especially under reverse ventilation conditions. These findings provide quantitative insights into fire-induced smoke dynamics in ultra-long tunnels, offering theoretical support for optimizing ventilation control and evacuation strategies in urban express systems.

18 September 2025 in Fire
Verified
Journal Article
Open access
PDF file
XYXiaodong Yang
Xiaodong Yang
WWWenbin Wei
Wenbin Wei
YCYujia Chen
Yujia Chen
Jiaming ZhaoJiaming Zhao
Jiaming Zhao
LYLi Yanlong
Li Yanlong
SFSaiya Feng
Saiya Feng
In order to provide fire-scene parameters for fire protection design and data support for fire safety management of waiting halls in high-speed railway stations, this study systematically investigated the combustion characteristics of single, two, and three massage chairs using an industrial calorimeter. The results showed the following: The change in heat release rate in the growth stage of the massage chairs’ combustion tests was consistent with the t2 fast fire (with a growth coefficient of 0.04689). The maximum HRR was 1.2 MW for the single-massage-chair combustion test, 2.5 MW for the two-massage-chairs combustion test, and 3.5 MW for the three-massage-chairs combustion test. In the full-scale massage chairs combustion test, setting a 6.0 m fire isolation zone could effectively serve the functions of fire prevention and heat insulation. Considering a certain safety margin, and with a safety factor of 1.5 adopted, it is recommended that a fire isolation zone with a width of 9.0 m be used in the waiting halls of high-speed railway stations, which provides a direct, actionable design basis for engineering practice.

3 June 2025 in Fire
Verified
Journal Article
Open access
PDF file
PDPeng Du
Peng Du
JLJing Liu
Jing Liu
CZCheng Zhang
Cheng Zhang
ZZZhixin Zheng
Zhixin Zheng
GGGuangyue Gu
Guangyue Gu
LYLi Yanlong
Li Yanlong
Small bookstores constructed before the 1970s have a high fire risk in the context of the revitalization of historical buildings; while the setup of simple sprinklers is an effective and cheap method of extinguishing fires, the parameters of the sprinklers are uncertain. In this study, small bookstores in Beijing were selected, and physical combustion experiments with/without a sprinkler system were carried out following the provisions of the Code for the Design of Sprinkler Systems. After the experiments, an FDS model was set up using fire dynamics software. The results show that the total heat release rate (HRR) of books and desks is related to the square of time, with a coefficient of 2.528 × 10−6, and the maximum heat release rate is 40 KW. Unlike the standard test, the physical combustion experiment is significantly affected by the space. According to numerical simulations, when the sprinkler flow velocity is 60~100 L/min, the water consumption of the sprinkler is 195~218 L. This study lays the foundation for the analysis of the combustion characteristics of small bookstores and provides data support for the installation of simple sprinkler systems in small bookstores.

24 July 2025 in Fire
Verified
Journal Article
Open access
PDF file
WWWenbin Wei
Wenbin Wei
Jiaming ZhaoJiaming Zhao
Jiaming Zhao
CZCheng Zhang
Cheng Zhang
LYLi Yanlong
Li Yanlong
SFSaiya Feng
Saiya Feng
This study aims to provide a reference for the fire protection design and fire emergency response strategies for fuel islands in high-speed railway stations and other transportation buildings. By using an industrial calorimeter, this paper analyzes the combustion characteristics of a fuel island. For the fuel island setup in this test, the fuel island fire development cycle was relatively long, and the maximum fire source heat release rate reached 4615 kW. Before the fire source heat release rate reaches the maximum peak, the HRR curve slowly fluctuates and grows within the first 260 s after ignition. Within the time range of 260 s to 440 s, the fire growth rate resembled that of a t2 medium-speed fire, and within the time range of 400 s to 619 s, it more closely aligned with a t2 fast fire. It is generally suggested that the growth curve of t2 fast fire could be used for the numerical simulation of fuel island fires. The 1 h fire separation method adopted in this paper demonstrated a good fire barrier effect throughout the combustion process.