Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.
Cathode spot motion influences the physical characteristics of arc plasma and the related macroparticles (MPs) in resultant films; these MPs limit the application of arc ion plating (AIP). In this paper, a scanning radial magnetic field (SRMF) was applied to the cathode surface to control the cathode spot motion and reduce the MP contamination in the deposited films. It was shown that film surface morphologies prepared using SRMF were better than those using a static radial magnetic field (RMF). The improvement was greater with increased scanning range and frequency. Using SRMF, cathode spot motion was confined to a spiral trajectory on the cathode surface and the spots moved over a large area and at a fast-moving velocity. Both the large moving area and the fast velocity decreased the temperature on the cathode surface and thus reduced the emission of the MPs.
Thermochemical adsorption energy storage is a potential energy utilization technology. Among these technologies, the composite energy storage material prepared by K2CO3 and expanded vermiculite (EVM) shows excellent performance. In this paper, the influence of the preparation process using the impregnation method and vacuum impregnation method on K2CO3/EVM composite material is studied. The preparation plan is further optimized with the solution concentration and the expanded vermiculite particle size as variables. In the experiment, mercury intrusion porosimetry (MIP) is used to measure the porosity and other parameters. Additionally, with the help of scanning electron microscopy (SEM), the morphological characteristics of the materials are obtained from a microscopic point of view. The effects of different preparation parameters are evaluated by comparing the experimental results. The results show that the K2CO3 specific gravity of the composite material increases with the increase of the vacuum degree, up to 70.440 wt.% (the vacuum degree is 6.7 kPa). Expanded vermiculite with a large particle size (3~6 mm) can carry more K2CO3, and content per cubic centimeter of K2CO3 can be as high as 0.466 g.
26 March 2018 in IOP Conference Series: Earth and Environmental Science
The application of microfluidic technology to manipulate cells or biological particles is becoming one of the rapidly growing areas, and various microarray trapping devices have recently been designed for high throughput single-cell analysis and manipulation. In this paper, we design a double-slit microfluidic chip for hydrodynamic cell trapping at the single-cell level, which maintains a high capture ability. The geometric effects on flow behaviour are investigated in detail for optimizing chip architecture, including the flow velocity, the fluid pressure, and the equivalent stress of cells. Based on the geometrical parameters optimized, the double-slit chip enhances the capture of HeLa cells and the drug experiment verifies the feasibility of the drug delivery.
NiCrAlY coating was prepared on a stainless steel substrate by an arc ion plating machine and the annealing experiments were carried out at different temperatures using a tube furnace. The effects of annealing temperatures on the morphology, structure, chemical composition and phase structure of the coating were characterized by SEM, EDS and XRD, respectively. The change of microstructure is discussed. Dynamic mechanical analyzer results determined the suitable annealing temperature for the best damping performance. The effect of annealing temperature on the microstructure and damping properties of NiCrAlY coating are also discussed. The relationship between annealing temperature and damping properties are explained by microstrcuture, grain size and phase structure.