Aim: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can capture subject-specific physiological characteristics and longitudinal changes in patients with diverse heart diseases. Method: Arterial pulse signals at the radial artery (RA) and carotid artery (CA) were recorded using microfabricated tactile sensors and analyzed with a single-degree-of-freedom time–frequency (SDOF-TF) framework. Key CV parameters, including heart rate (HR), heart rate variability (HRV), respiration rate (RR), respiration modulation (RM), harmonic amplitudes, and normalized arterial pulse waveform (APW), were extracted from measurements at-rest and post-exercise across three visits in eighteen patients with heterogeneous CV conditions. Longitudinal changes in CV parameters within subjects and variability between subjects were assessed. Results: Compared to a healthy reference, patients exhibited altered CV profiles indicative of impaired autonomic regulation. Common trends included reduced HRV, blunted post-exercise CV responses, and attenuation of higher-order harmonics at the RA. CA-derived APW features showed enhanced sensitivity to systolic upstroke slope compared to the RA. Marked inter-subject variability was evident, reflected in at-rest values of key CV parameters and 5min post-exercise responses, highlighting the need for personalized interpretation. Longitudinal measurements revealed mixed effects of exercise on the CV system, likely influenced by concurrent medication and the short observation period. Conclusion: The SDOF-TF framework applied to arterial pulse signals effectively reveals both shared and individualized CV dysfunctions, capturing qualitative harmonic signatures, site-specific differences, and complex parameter interactions not detected by conventional methods, offering potential improvements in diagnosis and treatment monitoring for patients with diverse CV diseases.
Objectives: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can reveal subject-specific characteristics in patients with atypical CV dynamics that may be obscured in group-level analyses. Methods: Seven special-case patients—including a heart transplant (HTx) recipient and individuals with bradycardia (low heart rate), low dicrotic notch (DN), and intermittent arterial pulse waveform (APW) variations—were analyzed across three visits over the cardiac rehabilitation period. Radial artery (RA) and carotid artery (CA) signals, acquired using microfabricated tactile sensors, were processed using a single-degree-of-freedom time–frequency (SDOF–TF) framework to extract multiple CV parameters. Results: The patients exhibited highly heterogeneous CV profiles. Subjects with low heart rate (HR) demonstrated blunted post-exercise responses. Subjects with low DN morphology exhibited elevated lower-order harmonic amplitudes. Patients with intermittent features showed cyclic variations in APW morphology at-rest and during post-exercise recovery. Across all cases, RA measurements generally provided more stable and interpretable individualized patterns across visits, whereas CA measurements were more susceptible to variability related to motion artifacts (MA) and sensor-artery interaction effects. Conclusions: The SDOF–TF framework successfully identifies individualized multi-parameter CV characteristics associated with diverse complex CV conditions of the seven cases. The findings support the potential value of individualized arterial pulse analysis for personalized CV monitoring and indicate that post-exercise assessment provides more distinctive characterization of CV dynamics than conventional at-rest analysis alone.
Aim: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can reveal subject-specific characteristics in patients with atypical CV dynamics. Methods: Seven special-case patients—including a heart transplant (HTx) recipient and individuals with bradycardia (low heart rate, HR), low dicrotic notch (DN), and intermittent arterial pulse waveform (APW) variations—were analyzed across three visits over the cardiac rehabilitation (CR) period. Radial artery (RA) and carotid artery (CA) signals, acquired using micro-fabricated tactile sensors, were processed using a single-degree-of-freedom time–frequency (SDOF–TF) framework to extract multiple CV parameters. The analysis focused on descriptive characterization of subject-specific CV patterns in individual patients. Results: The patients exhibited highly heterogeneous CV profiles. Individuals with low HR exhibited relatively limited post-exercise HR changes. Individuals with low DN morphology exhibited elevated lower-order harmonic amplitudes. Individuals with intermittent APW variations exhibited cyclic changes in APW morphology at rest and during post-exercise recovery. Although CV patterns at rest differed across individuals, post-exercise assessment revealed more distinctive individual-specific differences, including differences between individuals within the same phenotype-based case subset. Across all patients and visits, RA measurements provided more stable and interpretable subject-specific CV patterns, whereas CA measurements were more susceptible to motion artifacts (MA) and sensor noise. For individuals with intermittent APW variations, the CA signals exhibited extremely poor signal quality, limiting their suitability for physiological interpretation. Conclusions: The SDOF–TF framework enabled the characterization of subject-specific, multi-parameter CV dynamics in these seven special cases. The findings illustrate the potential value of arterial pulse analysis for the individualized characterization of atypical CV dynamics. Future studies involving larger patient cohorts are needed to further investigate these findings and establish their clinical utility.
Background/Objectives: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can capture subject-specific physiological characteristics and longitudinal changes in patients with diverse heart diseases. Method: Arterial pulse signals at the radial artery (RA) and carotid artery (CA) of each patient were successfully recorded from all 18 patients using micro-fabricated tactile sensors. Signal quality was screened before analysis, and the accepted signals were analyzed using a single-degree-of-freedom time–frequency (SDOF-TF) framework. Key CV parameters, including time-based indices—heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM), as well as harmonic amplitudes and normalized arterial pulse waveform (APW)—were extracted from measurements at rest and post-exercise across three rehabilitation visits in 18 patients with heterogeneous CV conditions. Longitudinal changes in CV parameters within subjects and variability between subjects were assessed. Results: Compared with a healthy reference, the patients exhibited heterogeneous CV profiles, with lower HRV in all patients except one with AF, who showed elevated HRV, and generally reduced post-exercise CV responses. Higher-order harmonic amplitudes were attenuated at the RA, while CA-derived APW measurements showed greater sensitivity to systolic upstroke slope. Marked inter-subject variability was evident in at-rest CV parameters and 5-min post-exercise responses. Longitudinal CV responses varied across rehabilitation visits, potentially reflecting multiple contributing factors. Conclusions: The 100% pulse acquisition rate supports the feasibility of the tactile sensor technology for pulse measurement, and the combined sensor technology and SDOF-TF framework enable quantitative characterization of shared and individualized CV patterns in cardiac patients and their post-exercise recovery, including time-based indices, harmonic signatures, site-specific differences, and interactions among CV parameters. These findings warrant further investigation in larger cohorts with appropriate physiological reference measurements.