M. Encarna Mico-Amigo

Dr. M. Encarna Mico-Amigo

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CBChristopher Buckley
Christopher Buckley
MMM. Encarna Mico-Amigo
M. Encarna Mico-Amigo
MDMichael Dunne-Willows
Michael Dunne-Willows
Alan GodfreyAlan Godfrey
Alan Godfrey
AHAodhán Hickey
Aodhán Hickey
SMSarah A Moore
Sarah A Moore
Asymmetry is a cardinal symptom of gait post-stroke that is targeted during rehabilitation. Technological developments have allowed accelerometers to be a feasible tool to provide digital gait variables. Many acceleration-derived variables are proposed to measure gait asymmetry. Despite a need for accurate calculation, no consensus exists for what is the most valid and reliable variable. Using an instrumented walkway (GaitRite) as the reference standard, this study compared the validity and reliability of multiple acceleration-derived asymmetry variables. Twenty-five post-stroke participants performed repeated walks over GaitRite whilst wearing a tri-axial accelerometer (Axivity AX3) on their lower back, on two occasions, one week apart. Harmonic ratio, autocorrelation, gait symmetry index, phase plots, acceleration, and jerk root mean square were calculated from the acceleration signals. Test–retest reliability was calculated, and concurrent validity was estimated by comparison with GaitRite. The strongest concurrent validity was obtained from step regularity from the vertical signal, which also recorded excellent test–retest reliability (Spearman’s rank correlation coefficients (rho) = 0.87 and Intraclass correlation coefficient (ICC21) = 0.98, respectively). Future research should test the responsiveness of this and other step asymmetry variables to quantify change during recovery and the effect of rehabilitative interventions for consideration as digital biomarkers to quantify gait asymmetry.

19 April 2016 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MMM. Encarna Mico-Amigo
M. Encarna Mico-Amigo
IKIdsart Kingma
Idsart Kingma
EAErik Ainsworth
Erik Ainsworth
SWStefan Walgaard
Stefan Walgaard
MNMartijn Niessen
Martijn Niessen
Jaap Van DieenJaap Van Dieen
Jaap Van Dieen
The assessment of short episodes of gait is clinically relevant and easily implemented, especially given limited space and time requirements. BFS (body-fixed-sensors) are small, lightweight and easy to wear sensors, which allow the assessment of gait at relative low cost and with low interference. Thus, the assessment with BFS of short episodes of gait, extracted from dailylife physical activity or measured in a standardised and supervised setting, may add value in the study of gait quality of the elderly. The aim of this study was to evaluate the accuracy of a novel algorithm based on acceleration signals recorded at different human locations (lower back and heels) for the detection of step durations over short episodes of gait in healthy elderly subjects. Twenty healthy elderly subjects (73.7 ± 7.9 years old) walked twice a distance of 5 m, wearing a BFS on the lower back, and on the outside of each heel. Moreover, an optoelectronic three-dimensional (3D) motion tracking system was used to detect step durations. A novel algorithm is presented for the detection of step durations from low-back and heel acceleration signals separately. The accuracy of the algorithm was assessed by comparing absolute differences in step duration between the three methods: step detection from the optoelectronic 3D motion tracking system, step detection from the application of the novel algorithm to low-back accelerations, and step detection from the application of the novel algorithm to heel accelerations. The proposed algorithm successfully detected all the steps, without false positives and without false negatives. Absolute average differences in step duration within trials and across subjects were calculated for each comparison, between low-back accelerations and the optoelectronic system were on average 22.4 ± 7.6 ms (4.0 ± 1.3 % of average step duration), between heel accelerations and the optoelectronic system were on average 20.7 ± 11.8 ms (3.7 ± 1.9 %), and between low-back accelerations and heel accelerations were on average 27.8 ± 15.1 ms (4.9 ± 2.5 % of average step duration). This study showed that the presented novel algorithm detects step durations over short episodes of gait in healthy elderly subjects with acceptable accuracy from low-back and heel accelerations, which provides opportunities to extract a range of gait parameters from short episodes of gait.

19 February 2019 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
MMM. Encarna Mico-Amigo
M. Encarna Mico-Amigo
IKIdsart Kingma
Idsart Kingma
SHSebastian Heinzel
Sebastian Heinzel
SRSietse M. Rispens
Sietse M. Rispens
THTanja Heger
Tanja Heger
Jaap Van DieenJaap Van Dieen
Jaap Van Dieen
Background and Aim: Development of objective, reliable and easy-to-use methods to obtain progression markers of Parkinson’s disease (PD) is required to evaluate interventions and to advance research in PD. This study aimed to provide quantitative markers of progression in idiopathic PD from the assessment of circular gait (walking in circles) with a single body-fixed inertial sensor placed on the lower back. Methods: The assessments were performed every 6 months over a (up to) 5 years period for 22 patients in early-stage PD, 27 patients in middle-stage PD and 25 healthy controls (HC). Longitudinal changes of 24 gait features extracted from accelerometry were compared between PD groups and HCs with generalized estimating equations (GEE) analysis, accounting for gait speed, age and levodopa medication state confounders when required. Results: Five gait features indicated progressive worsening in early stages of PD: number of steps, total duration and harmonic ratios calculated from vertical (VT), medio-lateral (ML), and anterior-posterior (AP) accelerations. For middle stages of PD, three gait features were identified as potential progression markers: stride time variability, and stride regularity from VT and AP acceleration. Conclusion: Faster progressive worsening of gait features in early and middle stages of PD relative to healthy controls over 5 years confirmed the potential of accelerometry-based assessments as quantitative progression markers in early and middle stages of the disease. The difference in significant parameters between both PD groups suggests that distinct domains of gait deteriorate in these PD stages. We conclude that instrumented circular walking assessment is a practical and useful tool in the assessment of PD progression that may have relevant potential to be implemented in clinical trials and even clinical routine, particularly in a developing digital era.

20 January 2017 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MMM. Encarna Mico-Amigo
M. Encarna Mico-Amigo
IKIdsart Kingma
Idsart Kingma
GFGert Faber
Gert Faber
AKA. Kunikoshi
A. Kunikoshi
JUJ. M. T. van Uem
J. M. T. van Uem
Jaap Van DieenJaap Van Dieen
Jaap Van Dieen
Quantitative assessment of gait in patients with Parkinson’s disease (PD) is an important step in addressing motor symptoms and improving clinical management. Based on the assessment of only 5 meters of gait with a single body-fixed-sensor placed on the lower back, this study presents a method for the identification of step-by-step kinematic parameters in 14 healthy controls and in 28 patients at early-to-moderate stages of idiopathic PD. Differences between groups in step-by-step kinematic parameters were evaluated to understand gait impairments in the PD group. Moreover, a discriminant model between groups was built from a subset of significant and independent parameters and based on a 10-fold cross-validated model. The discriminant model correctly classified a total of 89.5% participants with four kinematic parameters. The sensitivity of the model was 95.8% and the specificity 78.6%. The results indicate that the proposed method permitted to reasonably recognize idiopathic PD-associated gait from 5-m walking assessments. This motivates further investigation on the clinical utility of short episodes of gait assessment with body-fixed-sensors.

20 May 2025 in JMIR Formative Research
Verified
Journal Article
Open access
MBMartin A Berge
Martin A Berge
APAnisoara Paraschiv-Ionescu
Anisoara Paraschiv-Ionescu
CKCameron Kirk
Cameron Kirk
AKArne Küderle
Arne Küderle
MMM. Encarna Mico-Amigo
M. Encarna Mico-Amigo
BVBeatrix Vereijken
Beatrix Vereijken
Background: Algorithms estimating real-world digital mobility outcomes (DMOs) are increasingly validated in healthy adults and various disease cohorts. However, their accuracy and reliability in older adults after hip fracture, who often walk slowly for short durations, is underexplored. Objective: This study examined DMO accuracy and reliability in a hip fracture cohort considering walking bout (WB) duration, physical function, days since surgery, and walking aid use. Methods: In total, 19 community-dwelling participants were real-world monitored for 2.5 hours using a lower back wearable device and a reference system combining inertial modules, distance sensors, and pressure insoles. A total of 6 DMO estimates from 164 WBs from 58% (11/19) of the participants (aged 71-90 years; assessed 32-390 days after surgery; Short Physical Performance Battery [SPPB] scores of 3-12; gait speed range 0.39-1.34 m/s) were assessed against the reference system at the WB and participant level. We stratified by WB duration (all WBs, WBs of >10 seconds, WBs of 10-30 seconds, and WBs of >30 seconds) and lower versus higher SPPB scores and observed whether days since surgery and walking aid use affected DMO accuracy and reliability. Results: Across WBs, walking speed and distance ranged from 0.25 to 1.29 m/s and from 1.7 to 436.5 m, respectively. Estimation of walking speed, cadence, stride duration, number of steps, and distance stratified by WB duration showed intraclass correlation coefficients (ICCs) ranging from 0.50 to 0.99 and mean relative errors (MREs) from –6.9% to 12.8%. Stride length estimation showed poor reliability, with ICCs ranging from 0.30 to 0.49 and MREs from 6.1% to 13.2%. Walking speed and distance ICCs in the higher–SPPB score group ranged from 0.85 to 0.99, and MREs ranged from –10.1% to –1.7%. In the lower–SPPB score group, walking speed and distance ICCs ranged from 0.17 to 0.99, and MREs ranged from 13.5% to 32.6%. There was no discernible effect of time since surgery or walking aid use. Conclusions: In total, 5 accurate and reliable real-world DMOs were identified in older adults after hip fracture: walking speed, cadence, stride duration, number of steps, and distance. Accuracy and reliability of most DMOs improved when excluding WBs of 30 seconds than for WBs of 10 to 30 seconds and for participants with higher physical function. DMOs capture daily gait as early as 1 month after surgery also in people using walking aids. However, as most WBs in this cohort were short, there was a trade-off between improving accuracy and reliability by excluding short WBs and losing a substantial amount of data. These results have important implications for establishing the clinical validity of DMOs and evaluating the effects of interventions on daily-life gait, thereby facilitating the design of optimal care pathways.

14 January 2025 in Journal of Parkinson’s Disease
Verified
Journal Article
Open access
MMM. Encarna Mico-Amigo
M. Encarna Mico-Amigo
IKIdsart Kingma
Idsart Kingma
SHSebastian Heinzel
Sebastian Heinzel
SSSusanne Solbrig
Susanne Solbrig
MHMarkus A Hobert
Markus A Hobert
Jaap Van DieenJaap Van Dieen
Jaap Van Dieen
Background: Development of objective, reliable and easy-to-use methods to detect the onset of motor changes in Parkinson's disease (PD) is required to identify the temporal window in which neuromodulatory therapies could be implemented. Turning impairments are present at early stages of PD. However, it is unclear, to date, whether circular walking is also altered in prodromal PD. Objective: Explore the predictive potential of circular walking in prodromal PD. Methods: We included 102 subjects from a nine-year prospective cohort study (with 712 participants) in the current nested case-control analysis: 16 diagnosed with PD during follow-up (incident PD) and 96 healthy controls, matched in gender, age, and education with a 1:6 ratio. Forty-one gait features were extracted from baseline assessments with accelerometers under single and dual-tasking conditions. A Cox proportional hazards regression analysis was used to test the temporal association of non-correlated gait features to the probability of being diagnosed with PD. Results: We identified associations between time from baseline measurement to PD diagnosis for eleven gait features, mostly based on harmonic ratios, step and stride variability, and index of harmonicity, partially in combination with gait speed. Most significant associations indicated that low gait symmetry and low rhythmicity were associated with larger hazard of being diagnosed with PD. Area under the curve ranged 0.63-0.69. Conclusions: Despite low sensitivity and specificity, the findings potentially reflect prodromal motor impairments of PD manifested during circular walking, assessed quantitatively with a low-cost and wearable instrument. This will contribute to the characterization of pre-diagnostic PD motor symptoms.