Background/Objectives: Finite element analysis (FEA) can predict biomechanical performance of dental implants in compromised bone. In the posterior maxilla, low bone density, thin cortex, and variable regenerated bone stiffness may lead to pathological peri-implant strains. This study examined the effects of implant diameter, cortical thickness, cancellous bone type, and regenerated bone elasticity on strain distribution in short plateau (Bicon SHORT®) implants. Methods: Three-dimensional FEA models of type III and IV maxillae with cortical layers of 1.0, 0.75, and 0.5 mm were developed. Implants of 4.5, 5.0, and 6.0 mm diameter were tested, with regenerated bone elasticity set to 25–100% of cortical values. An oblique load of 120.9 N at 75° was applied under full osseointegration, and first principal strains were compared with Frost’s 3000 με threshold. Results: Cortical strains remained at physiological levels, but cancellous bone in type IV often exceeded 3000 με, especially with smaller diameters and low regenerated stiffness. Enlarging implant diameter to 6.0 mm lowered cancellous maximal first principal strain by up to 56% in type III and 36% in type IV bone. Reduced regenerated bone elasticity markedly increased risk, particularly with cortical thickness < 0.75 mm. Conclusions: Biomechanical risk depends on implant diameter and regenerated bone quality. Wide short implants (6.0 mm) most effectively limited pathological strain under low cortical support and poor regenerated stiffness. Patient-specific FEA may guide implant choice and improve outcomes in atrophic maxilla rehabilitation.
At present, the topic of traumatism of the maxillofacial region is topical and requires the search for contemporary biomechanical solutions. It is known that the problem of mandibular traumatism ranks first among all injuries of the maxillofacial region. Treatment of mechanically failured human mandible was considered as the example of its body fracture in accordance with European classification of maxillofacial trauma. This type of injury was chosen because of its widespread, statistically supported incidence. The treatment method was based on the use of osteosynthesis systems, widely used in the healthcare systems of Western European countries. The purpose of the study was in biomechanical support of existing clinical protocols for the osteosynthesis system elements application to ensure positive treatment prospects. Finite element analysis of acting deformations and displacements in the adjacent bone tissues was carried out for the case of reconstruction of the lower jaw damaged by an oblique fracture in its middle part (body) using two mini-plates in accordance with current clinical protocol. In our case, fracture was fixated with two 1.25 mm in thickness titanium mini-plates. Two types of mini-plates with lengths of 27 mm (long) and 20.5 mm (short) between the axes of the outer holes were analyzed. The results was revealed that osteosynthesis systems technology provides the conditions for the fixed mandible ridges healing under gentle functional loading due to safe micromotions which do not exceed 150 micrometer threshold of safe displacements (0.15 mm for long mini-plate 27×2.5×1.25 mm and 0.13 mm for short mini-plate 20.5×3.5×1.25mm). Also, the largest sliding distance in the fracture section are 0.11 mm for long mini-plate 27×2.5×1.25 mm and 0.06 mm for short mini-plate 27×2.5×1.25 mm. From this viewpoint, short mini-plate is recommended as preferable. However, care should be taken in transferring the results to the clinical situation. First of all, the wider range of possible bone fractures and their actual shapes with possible deviations from a flat contour should be taken into account. Also, more adequate simulation of the crack ridges interface should be provided to answer the question on micromotion data accuracy influencing the crack fixation and the success of the bone healing.
Implant-supported cantilever crowns can serve as a viable alternative in certain clinical scenarios to circumvent additional surgical procedures either prior to or concurrently with implant placement. Despite the favorable clinical results seen with cantilever crowns, concerns have been raised regarding the long-term biomechanical implications and associated technical challenges. Multiple research investigations have demonstrated that implant-supported cantilever crowns have the potential to generate heightened stress concentrations within the underlying alveolar bone. The aim of the study is in the biomechanical analysis of stress fields in atrophic posterior maxilla with implant-supported cantilever crown. Functionally important two molars loss was analyzed to provide the implant placement in atrophic maxilla with types III and IV bone, when implantation is complicated due to insufficient bone height (less than 10 mm), low bone density and rigidity, thin cortical core (thickness less or equal to 0.5 mm). In such challenging conditions, placement of cantilever crowns was proposed as an advanced approach. The recommendations for practitioners were formulated after thorough modeling of bone-implant interface with preliminary evaluation of stress fields in adjacent bone. Two (narrow and wide) implants of two lengths were studied (4.5×5.0 mm, 4.5×8.0 mm, 6.0×5.0 mm, 6.0×8.0 mm) as the supports for two teeth loss restoration. Also, a wide spectrum of human bone elasticity parameters was studied in order to generalize the results of the study to wide range of patients (patient-specific approach). Validation of FEA algorithms was provided to receive necessary accuracy of numerical analysis and support developed clinical recommendations. Based on the conducted research results, we draw the attention of implantologists to the fact that the load-bearing capacity of proposed cantilever crown which are supported by short plateau implants is predetermined by the adjacent bone strains because bone stresses in all studied restorative structures were less than the bone ultimate strength.