Noe Rodriguez

Prof. Noe Rodriguez

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NRNoe Rodriguez
Noe Rodriguez
JCJosé Vicente Cruz-Cruz
José Vicente Cruz-Cruz
AGAlejandro Gómez-Hernández
Alejandro Gómez-Hernández
RHRodrigo Hernandez
Rodrigo Hernandez
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
This paper presents the improvement of an ultrasonic pulse generator for a pipeline inspection gauge (PIG), which uses 64 transducers for inspecting distances up to 100 km with an axial resolution fixed at 3 mm and variable speeds between 0 and 2 m/s. An ultrasonic pulse generator is composed of a high-voltage (HV) MOSFETs, driver logic and an HV power supply. We used a DC-HV DC converter device as the HV power supply because it reduces the size of the ultrasound system considerably. However, pipeline geometry and inspection effects such as hammer and shock cause a variable pulse repetition frequency (PRF), producing voltage drops, poor quality of the HV pulse generated, failures in the dimensioning of defects and damage to devices by over-voltage. Our improvement is to implement a control scheme to maintain the high quality of the HV regardless of the variable PRF. To achieve this, we characterized three transfer functions of the DC-HV DC converter, varying the connected load to 10%, 45% and 80%. For the characterization, we used the least squares technique, considering an autoregressive exogenous (ARX) model. Later, we compared three control schemes: (1) proportional-integral-derivative (PID) tuned by simultaneous optimization of several responses (SOSR), (2) PID tuned by a neural network (NN) and (3) PI tuned by the analytical design method (ADM). The metrics used to compare the control schemes were the recovery time, the maximum over-voltage and the excess energy when the shock and hammer effects happen to occur. Finally, to verify the improvement of the HV pulser, we compared the ultrasonic pulses generated for various frequencies and amplitudes using the pulse generator with and without the control scheme.

21 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ARAntonio Ramirez
Antonio Ramirez
NRNoe Rodriguez
Noe Rodriguez
STSergio Torres-Torres
Sergio Torres-Torres
GRGuillermo Ronquillo-Lomeli
Guillermo Ronquillo-Lomeli
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
Pipeline inspection gauges (PIGs) carry out automatic pipeline inspection with nondestructive testing (NDT) technologies like ultrasound, magnetic flux leakage, and eddy current. The ultrasonic straight beam allows technicians to determine the wall thickness of the pipeline through the time of flight diffraction (TOFD), providing the pipeline reconstruction and allowing the detection of several defects like dents or corrosion. If the pipeline is of a long distance, then the inspection process is automatic, and the fluid pressure pushes the PIG through the pipeline system. In this case, the PIG velocity and its axial alignment with the pipeline cannot be controlled. The PIG geometry, the pipeline deformations, and the girth welds cause a continuous chattering when the PIG is running, removing the transducers perpendicularity with the inspection points, which means that some echoes cannot be received. To reduce this problem, we propose a novel method to design a sensor carrier that takes into account the angularity and distance effects to acquire the straight beam echoes. The main advantage of our sensor carrier is that it can be used in concave and convex pipeline sections through geometric adjustments, which ensure that it is in contact with the inner pipe wall. Our improvement of the method is the characterization of the misalignment between the internal wall of the pipeline and the transducer. Later, we analyzed the conditions of the automatic pipeline inspection, the existing recommendations in state-of-the-art technology, and the different mechanical scenarios that may occur. For the mechanical design, we developed all the equations and rules. At the signal processing level, we set a fixed gain in the filtering step to obtain the echoes in a defined distance range without saturating the acquisition channels. For the validation, we compared through the mean squared error (MSE) our sensor carrier in a straight pipe section and a pipe elbow of steel versus other sensor carrier configurations. Finally, we present the design parameters for the development of the sensor carrier for different pipeline diameters.

29 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
NRNoe Rodriguez
Noe Rodriguez
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
LBLeonardo Barriga
Leonardo Barriga
In invasive mechanical ventilation (IMV), it is critical that the flow value is estimated correctly, as it is used as a trigger variable for ventilatory assistance. Furthermore, the numerical integration of the flow allows the calculation of the total volume per breath (tidal volume), which clinicians use to identify trauma or lung capacity in the patient. The current COVID-19 pandemic has demonstrated the need to develop safe and efficient techniques for measuring this spirometry variable because many mechanical ventilators delivered to hospitals were unable to measure it directly. A good device to estimate flow is a D-lite sensor, which works by the Venturi effect, is cheap, reusable, and proximal to the patient. However, the regressions applied to the flow estimation model are limited for use in real conditions. This article presents a flow estimation method that uses a D-Lite device, a fraction of inspired oxygen (FiO 2 ) cell, and two pressure sensors as critical items. Our novel method adapts the dichotomous search algorithm instead of conventional regression algorithms to estimate flow using a D-lite sensor; this change in the standard procedure allowed us a fast calibration process, a good low-flow estimation, and low computational time for flow estimation. The method was validated experimentally to compute the tidal volume according to the measurement requirement error range of +/−10%. The consideration of FiO 2 percentage in the gas mixture and the good low-flow estimation make this novel method useful for real ventilation conditions. The flow calculations have been performed at different ambient conditions and compared with gas analyzers show an average relative error of up to 4.86%. Finally, we present an analysis of the error flow estimation considering the variation in each variable. Technical recommendations for applying this novel method to achieve IMV safely are presented, based on the capabilities of the embedded system used by developers.

1 January 2022 in Applied Soft Computing
Verified
Journal Article
Closed access
ARAdrian Rubio-Solis
Adrian Rubio-Solis
UHUriel Martinez Hernandez
Uriel Martinez Hernandez
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
LGLuis Garcia-Valdovinos
Luis Garcia-Valdovinos
NRNoe Rodriguez
Noe Rodriguez
TSTomas Salgado-Jimenez
Tomas Salgado-Jimenez

14 March 2018 in IEEE Transactions on Computers
Verified
Journal Article
Open access
NRNoe Rodriguez
Noe Rodriguez
AGA. Gomez-Hernandez
A. Gomez-Hernandez
LNL. Nava-Balanzar
L. Nava-Balanzar
Hugo Jimenez HernandezHugo Jimenez Hernandez
Hugo Jimenez Hernandez
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
In this manuscript, we present a redundant data storage system based on NAND flash memory chips for in-line Pipeline Inspection Gauges (PIGs). The system is the next step for a technique that reduces data from 1,024 to 37 bytes by 80 transducers used for straight-beam ultrasonic inspection. Each inspection is costly, because PIGs check pipelines up to 100 Km, collecting data every 3 mm and reaching speeds of 2 m/s. These conditions require that the storage system must be redundant, and able to maintain a minimum data flow, thus avoiding bottlenecks. To achieve this, we analyzed the variables that influence the inspection process in real-time, and we structured our Flash Translation Layer (FTL) to eliminate the latencies generated by the computation of the Error Correcting Codes (ECC) and redundancy bytes. Our controller computes the ECC and redundancy bytes while it transfers the information to the cache register of the selected die in the memory chips. At the hardware level, we interleaved 8 NAND flash chips in a Redundant Array of Independent Disks (RAID) type-6 architecture. We tested the storage system considering the incorrect response of up to 2 chips and ensuring a throughput up to 7.28 MB/s. Finally, we expanded the analysis of the data flow, whereby this system is profitable for different pipeline diameters or compression techniques.

Verified
Journal Article
Open access
PDF file
Juan Orozco-MuñizJuan Orozco-Muñiz
Juan Orozco-Muñiz
Tomas Salgado JimenezTomas Salgado Jimenez
Tomas Salgado Jimenez
NRNoe Rodriguez
Noe Rodriguez
The Variable Buoyancy System (VBS) is a critical device in the operation of underwater gliders that should be properly sized to achieve the required vehicle propulsion; safety within the operating range; and adequate efficiency at the nominal depth rating. The VBS budget volume depends mainly on the glider hydrodynamics and the main operating states of the vehicle. A method is proposed with analytical equations to analyze the performance of underwater gliders and to estimate the resultant velocities of the vehicle as a function of the buoyancy change and the glider angle. The method is validated to analyze the glider performance of underwater gliders and is essential to get the main design requirement for the propulsion system: the VBS budget volume. The paper presents the application of the method to obtain the VBS sizing for an academic glider; a comparison with the historical hydrodynamic data of the Slocum glider; the results of the glider performance study; and the development of the characteristic charts necessary to evaluate the performance of the vehicle and its flight parameters.