Leonardo Barriga

Dr. Leonardo Barriga


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
NRNoe Rodriguez
Noe Rodriguez
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
LBLeonardo Barriga
Leonardo Barriga
In invasive mechanical ventilation (IMV), it is critical that the flow value is estimated correctly, as it is used as a trigger variable for ventilatory assistance. Furthermore, the numerical integration of the flow allows the calculation of the total volume per breath (tidal volume), which clinicians use to identify trauma or lung capacity in the patient. The current COVID-19 pandemic has demonstrated the need to develop safe and efficient techniques for measuring this spirometry variable because many mechanical ventilators delivered to hospitals were unable to measure it directly. A good device to estimate flow is a D-lite sensor, which works by the Venturi effect, is cheap, reusable, and proximal to the patient. However, the regressions applied to the flow estimation model are limited for use in real conditions. This article presents a flow estimation method that uses a D-Lite device, a fraction of inspired oxygen (FiO 2 ) cell, and two pressure sensors as critical items. Our novel method adapts the dichotomous search algorithm instead of conventional regression algorithms to estimate flow using a D-lite sensor; this change in the standard procedure allowed us a fast calibration process, a good low-flow estimation, and low computational time for flow estimation. The method was validated experimentally to compute the tidal volume according to the measurement requirement error range of +/−10%. The consideration of FiO 2 percentage in the gas mixture and the good low-flow estimation make this novel method useful for real ventilation conditions. The flow calculations have been performed at different ambient conditions and compared with gas analyzers show an average relative error of up to 4.86%. Finally, we present an analysis of the error flow estimation considering the variation in each variable. Technical recommendations for applying this novel method to achieve IMV safely are presented, based on the capabilities of the embedded system used by developers.

1 March 2015 in Measurement
Verified
Journal Article
Closed access
KHKarla-Teresa Hernández-Díaz
Karla-Teresa Hernández-Díaz
AVAlberto Vazquez-Cervantes
Alberto Vazquez-Cervantes
José-Joel Gonzalez-BarbosaJosé-Joel Gonzalez-Barbosa
José-Joel Gonzalez-Barbosa
LBLeonardo Barriga
Leonardo Barriga
AHAna M. Herrera-Navarro
Ana M. Herrera-Navarro
Hugo Jimenez HernandezHugo Jimenez Hernandez
Hugo Jimenez Hernandez

2 December 2024 in IEEE Access
Verified
Journal Article
Open access
CSCristian Hamilton Sánchez Saquín
Cristian Hamilton Sánchez Saquín
LBLeonardo Barriga
Leonardo Barriga
LBLeonardo A. Baldenegro-Pérez
Leonardo A. Baldenegro-Pérez
GRGuillermo Ronquillo-Lomeli
Guillermo Ronquillo-Lomeli
NRNoe Rodriguez
Noe Rodriguez
A novel method for camera calibration in underwater environments using convolutional networks is presented. Two modified neural network architectures, ZCalibAquaNet and BCalibAquaNet, were developed for calibration matrix estimation from chessboard images in underwater environments. The process began with the training of the InceptionResNetV2 neural network from scratch, followed by the adjustment of the dense layers for regression and calibration matrix estimation. To ensure a suitable underwater environment, the dataset used in this work was created by the authors, using a ZED 2 stereo camera with a resolution of 1280 x 720 pixels and a baseline of 12 cm. A total of 2700 images were captured in an underwater environment. Three distinct scenes clean, green and blue waters were used to study the network performance under different lighting and color conditions. For network training, the Mean Squared Error (MSE) was used as the loss function, and the L 2 norm was applied to the dense layers for 256 epochs. Additionally, 3D reconstruction of objects with known geometry in underwater environments was performed. The results showed that both networks, ZCalibAquaNet and BCalibAquaNet, provided better camera calibration and improved the measurement quality in underwater environments compared to Zhang and Bouquet models.

7 August 2018 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
FCFernando Carrizosa‐Corral
Fernando Carrizosa‐Corral
AVAlberto Vazquez-Cervantes
Alberto Vazquez-Cervantes
JMJosue Rafael Montes Martínez
Josue Rafael Montes Martínez
KHKarla-Teresa Hernández-Díaz
Karla-Teresa Hernández-Díaz
JVJulio César Solano Vargas
Julio César Solano Vargas
Hugo Jimenez HernandezHugo Jimenez Hernandez
Hugo Jimenez Hernandez

8 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SASadot Arciniega-Montiel
Sadot Arciniega-Montiel
GRGuillermo Ronquillo-Lomeli
Guillermo Ronquillo-Lomeli
RSRoberto Salas
Roberto Salas
Tomas Salgado JimenezTomas Salgado Jimenez
Tomas Salgado Jimenez
LBLeonardo Barriga
Leonardo Barriga
The perinatal mortality rate is very high throughout the world. A fetal monitor may be used remotely, and this would tackle the problem of continuous monitoring of high-risk pregnancies. There is evidence that current technology is of low reliability, and, therefore, of low precision to identify fetal health. In medical technological implementation, a safe, efficient, and reliable operation must be guaranteed, and the main problem is that remote fetal monitor gathers just a few samples, so the hypothesis of classical theory is not met. We are proposing an approach that improves the data’s lack of reliability that accompanies the use of a remote fetal monitor. The method refers to how, by using the existing technologies and the initial experimental data, it is possible to apply probabilistic models that are truly representative of each application. This leads to the characterization of properties of the statistics used to generate a representative probabilistic model without the need to consider the hard suppositions. Results show that, for every case study, it was possible to improve estimations of measurement uncertainty. The proposed method is a useful tool to increase the reliability of medical technology, especially for pieces of equipment where a health care professional is not available.

25 April 2022 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
GRGuillermo Ronquillo-Lomeli
Guillermo Ronquillo-Lomeli
NRNoe Rodriguez
Noe Rodriguez
LBLeonardo Barriga
Leonardo Barriga
ARAntonio Ramírez-Martínez
Antonio Ramírez-Martínez
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
LNLuciano Nava-Balanzar
Luciano Nava-Balanzar
Pollutant emissions into the atmosphere are recognized as a significant problem in fossil fuel combustion. The pollution emission measurement in industrial boilers is difficult and expensive but fundamental for monitoring and controlling. Frequently continuous emissions monitoring (CEM) system is out of service or useless due to obsolescence, high maintenance cost, and so on or simply is not installed. When a system for measuring pollutant emissions is not available, an alternative method must be employed to get the pollutant emission value. According to the black-box model approach, this article describes the nonlinear modeling of NOx emissions from a utility boiler. Bayesian-Gaussian (BG), multilayer perceptron (MLP), and Volterra polynomial basis functions (VPBF) neural networks are developed for model benchmarking. Experimental data from a utility boiler was acquired in order to model definition and evaluation. The models process three boiler variables oxygen excess, fuel mass flow and flue gas recirculation gates for NOx emission estimation. Models with BG show better performance than models with MLP and VPBF for NOx prediction. Implications: The technology to control NOx emissions generated by combustion operates under strict regulations. In order to reduce NOx emissions, theoretical models of NOx generation have been studied extensively, including nitrogen chemistry and the dynamic flow of gas particles which is very complex. The new technology trends would require the continuous measurement of high precision NOx emissions to achieve further reductions in NOx emissions. Currently, NOx emissions are measured by a Continuous Emission Monitoring system, which turns out to be extremely expensive and difficult to maintain, so alternative low-cost solutions are desirable. Our contribution shows how algorithms based on different artificial intelligence techniques are viable and quality alternatives for the measurement of continuous NOx emissions. The NOx emissions models based on IA algorithms are viable alternatives that have versatility and self-tuning capacity due to the fact that they are based on boiler operation parameters which have valuable information few explored nowadays.