Neil Moffat

Dr. Neil Moffat

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
NMNeil Moffat
Neil Moffat
RBRichard Bates
Richard Bates

12 June 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
JDJairo Antonio Villegas Dominguez
Jairo Antonio Villegas Dominguez
NMNeil Moffat
Neil Moffat
DMDzmitry Maneuski
Dzmitry Maneuski
OFOscar Ferrer
Oscar Ferrer
GPGiulio Pellegrini
Giulio Pellegrini
SHSalvador Hidalgo
Salvador Hidalgo

19 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SOSebastian Onder
Sebastian Onder
PGPhilipp Gaggl
Philipp Gaggl
JBJürgen Burin
Jürgen Burin
AGAndreas Gsponer
Andreas Gsponer
MKMatthias Knopf
Matthias Knopf
TBThomas Bergauer
Thomas Bergauer

25 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlbert Doblas Moreno
Albert Doblas Moreno
DFDavid Flores
David Flores
SHSalvador Hidalgo
Salvador Hidalgo
NMNeil Moffat
Neil Moffat
GPGiulio Pellegrini
Giulio Pellegrini
PFPablo Fajardo
Pablo Fajardo
Pixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for surface damage irradiation by developing a new generation of iLGADs, the periphery of which is optimized to improve the performance of irradiated sensors. The fabricated iLGAD sensors exhibit good electrical performances before and after X-ray irradiation.

11 January 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NMNeil Moffat
Neil Moffat
JOJose Alfonso Soto Oton
Jose Alfonso Soto Oton
GRGemma Rius
Gemma Rius
ECEnric Cabruja
Enric Cabruja
GPGiulio Pellegrini
Giulio Pellegrini
We introduce an innovative graphene-on-silicon photodiode designed for low penetrating radiation. Its standout feature lies in its remarkably-thin dead layer in the entrance window, setting it apart from existing photodetectors. Conventional photodetectors suffer from sensitivity limitations in the low wavelength or energy, respectively, for light or particles, due to their shallow penetration depth. Most conventional photodiodes employ a junction implant which suffers from recombination of low-penetrating photons/particles within the dead layer. Instead, we utilise the nearly transparent properties of single-layer graphene to create a depletion layer that minimises the dead layer. We combine a single junction ring (highly doped $$n^{++}$$ bias ring) with single-layer graphene. The graphene acts as a field plate, extended over the junction ring and covering the entire entrance window (5 $$\times$$ 5 $$mm^2$$ active area), while being electrically isolated by an ultrathin, high K dielectric layer. In operation, the photodiode undergoes depletion upon applying a reverse bias as expected, which primarily occurs within the region beneath the field plate. We conducted Transient Current Technique measurements as the best method to assess the charge collection uniformity of the device. Remarkably, the results reveal a consistent total 100% uniformity across the entire detector area. Nevertheless, while the collection time is position-dependent, increasing as the laser incidence point moves farther away from the bias ring, responsivity measurements show excellent response in both the deep ultra violet and vacuum ultra violet regions with $$\ge$$ 100% external quantum efficiency at wavelengths below 150 nm.

1 November 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
PSP. Svihra
P. Svihra
RBR. Bates
R. Bates
JBJ. Braach
J. Braach
EBE. Buschmann
E. Buschmann
DDD. Dannheim
D. Dannheim
YOY. Otarid
Y. Otarid
This contribution reports on characterisation results of a large-area (2 cm2) small pitch (55 µm) inverse Low-Gain Avalanche Detector (iLGAD), bonded to a Timepix3 readout chip. The ilGAD sensors were produced by Micron Semiconductor Ltd with the goal to obtain good gain uniformity and maximise the fill-factor — an issue present with standard small-pitch LGAD designs. We have conducted detailed performance evaluations using both X-ray calibrations and beam tests. An X-ray fluorescence setup has been used to obtain energy calibration and to identify the optimal operating settings of the new devices, whereas the extensive beam tests allowed for a detailed evaluation of the detector performance. The beam-tests were performed at the CERN SPS North Area H6 beamline, using a 120 GeV/c pion beam. The reference tracking and time-stamping is achieved by a Timepix3-based beam telescope setup. The results show a gain of around 5 with very good uniformity, measured across the whole gain area, as well as a hit time resolution down to 1.3 ns without correcting for the time-walk effects. Furthermore, it is shown that the gain opens the possibility of a good X-ray energy resolution down to 4.5 keV.