ELİF YILMAZ BİÇER

Dr. ELİF YILMAZ BİÇER

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2025 in Journal of the American Ceramic Society
Verified
Journal Article
Closed access
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
EÖEsra Kaynak Öztürk
Esra Kaynak Öztürk
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör

Verified
Journal Article
Open access
PDF file
BGBeyza Güney
Beyza Güney
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
DDDilan Gizem Doğan
Dilan Gizem Doğan
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
Background: Zirconia ceramics are generally used in monolithic restorations, and their microstructural, mechanical, and optical properties continue to improve. Several factors affect the mechanical properties of these restorations; however, the combined effects of yttria content and margin design on the fracture resistance remain unclear. Methods: Sixty monolithic zirconia crowns were fabricated and assigned to six groups (n = 10) based on three different yttria contents (strength-gradient multilayer zirconia containing 3 mol% yttria tetragonal zirconia polycrystals in the dentin region and 5 mol% yttria-partially stabilized zirconia in the occlusal region: 3Y-TZP/5Y-PSZ [ZP], 3 mol% yttria tetragonal zirconia polycrystals: 3Y-TZP [HTML], and 4 mol% yttria-partially stabilized zirconia: 4Y-PSZ [STML]), and two different margin designs (chamfer and rounded shoulder). Crowns were adhesively bonded to standardized 3-dimensional-printed resin dies and subjected to thermal and mechanical aging (10,000 thermocycles at 5–55 °C, and 1.2 million mechanical cycles at 50 N, 1.6 Hz). Fracture resistance values were recorded in Newtons, and fracture types were evaluated. Data were analyzed using a two-way analysis of variance (ANOVA), and Bonferroni adjustment was used for multiple comparisons (α = 0.05). Results: A significant interaction between yttria content and margin design was found (p = 0.005). In the chamfer margin design groups, ZP (2208.5 ± 501.9 N) and HTML (2069.6 ± 463.3 N) showed significantly higher fracture resistance than STML (1444 ± 303.2 N) (p < 0.05). In the rounded shoulder margin design groups, no significant differences were observed among ZP (1662.8 ± 293.8 N), HTML (1940.9 ± 341.6 N), and STML (1795.6 ± 529.6 N) (p > 0.05). ZP and HTML showed higher fracture resistance values with the chamfer margin design, while STML showed higher fracture resistance with the rounded shoulder margin design. Conclusions: The fracture resistance of zirconia restorations is influenced by both the margin design and the yttria content. Designing the margin geometry based on the type of zirconia to be used can enhance the mechanical properties of the restorations and support clinical decision-making.

8 March 2026 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
CACemal Aydın
Cemal Aydın
Objective: This in vitro study aimed to evaluate the effects of substructure color and restoration thickness on the final color of shade‐gradient ultra‐translucent zirconia ceramics. Material and Methods: A total of 180 flat‐shaped ultra‐translucent zirconia specimens (5Y‐PSZ) with thicknesses of 0.4, 0.6, and 0.8 mm ( n = 60) were fabricated and cemented onto composite substructures in six colors (A1, A2, B1, B2, C2, D2). Color parameters were measured before and after cementation, and color differences (Δ E 00 ) were calculated using the CIEDE2000 formula. The data were evaluated using the two‐way repeated measures of ANOVA, Kruskal–Wallis, Tukey HSD, and Bonferroni tests ( α = 0.05). Results: Substructure color and restoration thickness had significant effects on Δ E 00 ( p < 0.001) after cementation, with values exceeding the acceptability threshold (1.8) in all groups. Before and after cementation, A2 remained below the acceptability threshold relative to target color A1 and B2 achieved acceptable color matching with increased thickness. Conclusions: Restoration thickness and substructure color significantly influenced the final color of shade‐gradient zirconia ceramics. A2 provided better color matching, while B2 required a minimum thickness of 0.8 mm for acceptable results. Clinical Significance: Increased zirconia thickness enhances masking of darker substructures. Additionally, the influence of the substructure color must be carefully considered, particularly in thinner ultra‐translucent zirconia ceramics, to ensure predictable, harmonious color matching.

1 January 2026 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
BGBeyza Güney
Beyza Güney
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
The objective of the present in vitro study is to evaluate the color prediction of shade-gradient 5 mol% yttria-partially stabilized zirconia (5Y-PSZ) ceramics in different thicknesses using try-in pastes, unpolymerized resin cements, and polymerized resin cements. Specimens with thicknesses of 0.4 mm, 0.6 mm, and 0.8 mm were fabricated using 5Y-PSZ zirconia ceramic. Substructure specimens were prepared from composite resin in A1 shade. Color parameters were measured after try-in paste application, before resin cement polymerization, and after resin cement polymerization. The color differences between the try-in paste and the unpolymerized resin cement (ΔE00-1), the try-in paste and the polymerized resin cement (ΔE00-2), and the unpolymerized resin cement and polymerized resin cement (ΔE00-3) were calculated using the CIEDE2000 formula. Data were statistically analyzed using the two-way repeated-measures ANOVA and the Bonferroni adjustment (α = 0.05). Two-way repeated-measures ANOVA revealed no interaction between thickness and prediction method (P = .128), but both factors significantly affected ΔE00 values (P < .05). Among the thickness groups, 0.4 mm specimens showed the highest ΔE00 values (1.45 ±0.9), while 0.6 mm and 0.8 mm specimens demonstrated significantly lower ΔE00 values (P < .05). Regarding the prediction method, all groups showed statistically significant differences (P < .05), with ΔE00-1 exhibiting the highest ΔE00 value (1.38 ±0.7), followed by ΔE00-2 and ΔE00-3. In thin restorations (0.4 mm), color prediction became more challenging. Visually perceptible color differences were observed among try-in pastes and resin cements after polymerization; therefore, the use of unpolymerized resin cement yielded more reliable color prediction.

5 May 2026 in British Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
EÇEsma Nur Çetin
Esma Nur Çetin
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
BBBilge Turhan Bal
Bilge Turhan Bal
SNSecil Karakoca Nemli
Secil Karakoca Nemli

25 November 2025 in Polymers
Verified
Journal Article
Open access
PDF file
EÖEsra Kaynak Öztürk
Esra Kaynak Öztürk
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
BGBeyza Güney
Beyza Güney
SSSina Saygili
Sina Saygili
NANagehan Aktas
Nagehan Aktas
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
This study investigated the effects of resin cement shade and thermocycling on the color parameters and final appearance of SLA-printed photopolymer resins. Specimens with a thickness of 1 mm were fabricated and categorized into eight groups based on four different cement shades (universal-A2, clear, white, and opaque) and two applications (cementation and thermal aging). Differences in color parameters (ΔL*, Δa*, and Δb*) were measured after cement polymerization and thermocycling, and overall color differences (ΔE00-1 and ΔE00-2) were calculated. Two-way ANOVA revealed significant interactions between cement shade and thermocycling for ΔL*, Δa*, and Δb* (p < 0.05). After cementation, L* decreased for universal-A2, clear, and white cements, but increased for opaque cement. Furthermore, thermocycling altered L*, a*, and b* values differently among the experimental groups. Cement shade significantly influenced ΔE00, with universal-A2 and clear cements showing higher values than white and opaque cements (p < 0.05). All ΔE00 values exceeded the clinically acceptable limit (>1.8). The findings suggest that careful selection of the cement shade is therefore critical to achieving optimal esthetic outcomes with the tested 3D-printed resin. Formlabs SLA-printed permanent resin, although labeled as an A2 shade, behaves more like white or opaque shades, highlighting inconsistencies between labeled and actual color.