Beyza Güney

Dr. Beyza Güney

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BGBeyza Güney
Beyza Güney
ANAsude Dilek Nalbant
Asude Dilek Nalbant
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
This study aimed to evaluate the effect of different manufacturing techniques and thermal aging on the fracture resistance of provisional crowns and fixed partial dentures. Methods: A total of 60 provisional crowns and 60 provisional fixed partial dentures were fabricated using three manufacturing techniques: conventional manufacturing (CM), subtractive manufacturing (SM), and additive manufacturing (AM). An index created from SM-manufactured restorations was used to produce the CM group. Artificial abutments were created by duplicating scanned phantom teeth using model resin. Half of the restorations (n = 10 per group) were subjected to thermal aging (5–55 °C, 5000 cycles). The fracture resistance values of the specimens were tested using a universal testing machine. Data were analyzed using a two-way ANOVA and Tukey’s post hoc tests (α = 0.05). The highest mean fracture resistance was observed in the SM group without aging, both for crowns (1645.4 ± 346.8 N) and fixed partial dentures (1291.13 ± 564.15 N). The two-way ANOVA revealed statistically significant differences among the groups, and thermal aging significantly reduced the fracture resistance (p < 0.05). Both the manufacturing method and thermal aging significantly influenced the fracture resistance of provisional crowns and fixed partial dentures. In fixed partial dentures, a significant effect of aging was associated with the reduced durability of restorations fabricated using the subtractive manufacturing method.

Verified
Journal Article
Open access
PDF file
BGBeyza Güney
Beyza Güney
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
DDDilan Gizem Doğan
Dilan Gizem Doğan
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
Background: Zirconia ceramics are generally used in monolithic restorations, and their microstructural, mechanical, and optical properties continue to improve. Several factors affect the mechanical properties of these restorations; however, the combined effects of yttria content and margin design on the fracture resistance remain unclear. Methods: Sixty monolithic zirconia crowns were fabricated and assigned to six groups (n = 10) based on three different yttria contents (strength-gradient multilayer zirconia containing 3 mol% yttria tetragonal zirconia polycrystals in the dentin region and 5 mol% yttria-partially stabilized zirconia in the occlusal region: 3Y-TZP/5Y-PSZ [ZP], 3 mol% yttria tetragonal zirconia polycrystals: 3Y-TZP [HTML], and 4 mol% yttria-partially stabilized zirconia: 4Y-PSZ [STML]), and two different margin designs (chamfer and rounded shoulder). Crowns were adhesively bonded to standardized 3-dimensional-printed resin dies and subjected to thermal and mechanical aging (10,000 thermocycles at 5–55 °C, and 1.2 million mechanical cycles at 50 N, 1.6 Hz). Fracture resistance values were recorded in Newtons, and fracture types were evaluated. Data were analyzed using a two-way analysis of variance (ANOVA), and Bonferroni adjustment was used for multiple comparisons (α = 0.05). Results: A significant interaction between yttria content and margin design was found (p = 0.005). In the chamfer margin design groups, ZP (2208.5 ± 501.9 N) and HTML (2069.6 ± 463.3 N) showed significantly higher fracture resistance than STML (1444 ± 303.2 N) (p < 0.05). In the rounded shoulder margin design groups, no significant differences were observed among ZP (1662.8 ± 293.8 N), HTML (1940.9 ± 341.6 N), and STML (1795.6 ± 529.6 N) (p > 0.05). ZP and HTML showed higher fracture resistance values with the chamfer margin design, while STML showed higher fracture resistance with the rounded shoulder margin design. Conclusions: The fracture resistance of zirconia restorations is influenced by both the margin design and the yttria content. Designing the margin geometry based on the type of zirconia to be used can enhance the mechanical properties of the restorations and support clinical decision-making.

18 June 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
BTBaris erkut Turk
Baris erkut Turk
BBBersu Bedirhandede
Bersu Bedirhandede
DDDilan Gizem Doğan
Dilan Gizem Doğan
BGBeyza Güney
Beyza Güney
Background/Objectives: Patient-specific subperiosteal implants are increasingly used to treat severely atrophic ridges due to advances in digital planning and additive manufacturing. This study aimed to evaluate the effects of material type and implant configuration on stress distribution in subperiosteal implant systems and to compare their overall biomechanical performance using a multi-criteria decision framework. Methods: A three-dimensional model of a severely atrophic maxilla was reconstructed to simulate four clinical scenarios combining two configurations (one-piece and two-piece) and two materials (titanium and 60% carbon fiber-reinforced polyetheretherketone). Finite element analysis was conducted to assess stress distribution within the implant body, fixation screws, prosthetic framework, and surrounding bone under vertical and oblique loading conditions. Maximum and minimum principal stresses were evaluated in bone, whereas von Mises stresses were calculated for implant components. The resulting biomechanical indicators were subsequently integrated using an entropy weight–TOPSIS multi-criteria decision analysis. Results: Principal stresses in the surrounding bone showed minimal variation between titanium and 60% carbon fiber-reinforced polyetheretherketone across all configurations. Implant configuration had a more pronounced effect on implant body stress. Under oblique loading, the two-piece configuration demonstrated substantially higher implant stresses than the one-piece design, whereas under vertical loading, lower implant stresses were observed in the two-piece configuration. The multi-criteria analysis ranked the one-piece titanium model highest under oblique loading and the two-piece titanium model highest under vertical loading. Conclusions: Implant configuration and loading direction influenced biomechanical behavior more than material selection in patient-specific subperiosteal implants.

30 September 2026 in Journal of Prosthodontics
Verified
Journal Article
Closed access
BBBersu Bedirhandede
Bersu Bedirhandede
BGBeyza Güney
Beyza Güney
DDDilan Gizem Doğan
Dilan Gizem Doğan
BTBaris erkut Turk
Baris erkut Turk

25 November 2025 in Polymers
Verified
Journal Article
Open access
PDF file
EÖEsra Kaynak Öztürk
Esra Kaynak Öztürk
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
BGBeyza Güney
Beyza Güney
SSSina Saygili
Sina Saygili
NANagehan Aktas
Nagehan Aktas
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
This study investigated the effects of resin cement shade and thermocycling on the color parameters and final appearance of SLA-printed photopolymer resins. Specimens with a thickness of 1 mm were fabricated and categorized into eight groups based on four different cement shades (universal-A2, clear, white, and opaque) and two applications (cementation and thermal aging). Differences in color parameters (ΔL*, Δa*, and Δb*) were measured after cement polymerization and thermocycling, and overall color differences (ΔE00-1 and ΔE00-2) were calculated. Two-way ANOVA revealed significant interactions between cement shade and thermocycling for ΔL*, Δa*, and Δb* (p < 0.05). After cementation, L* decreased for universal-A2, clear, and white cements, but increased for opaque cement. Furthermore, thermocycling altered L*, a*, and b* values differently among the experimental groups. Cement shade significantly influenced ΔE00, with universal-A2 and clear cements showing higher values than white and opaque cements (p < 0.05). All ΔE00 values exceeded the clinically acceptable limit (>1.8). The findings suggest that careful selection of the cement shade is therefore critical to achieving optimal esthetic outcomes with the tested 3D-printed resin. Formlabs SLA-printed permanent resin, although labeled as an A2 shade, behaves more like white or opaque shades, highlighting inconsistencies between labeled and actual color.

1 January 2026 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
EBELİF YILMAZ BİÇER
ELİF YILMAZ BİÇER
BGBeyza Güney
Beyza Güney
MGMerve Bankoğlu Güngör
Merve Bankoğlu Güngör
The objective of the present in vitro study is to evaluate the color prediction of shade-gradient 5 mol% yttria-partially stabilized zirconia (5Y-PSZ) ceramics in different thicknesses using try-in pastes, unpolymerized resin cements, and polymerized resin cements. Specimens with thicknesses of 0.4 mm, 0.6 mm, and 0.8 mm were fabricated using 5Y-PSZ zirconia ceramic. Substructure specimens were prepared from composite resin in A1 shade. Color parameters were measured after try-in paste application, before resin cement polymerization, and after resin cement polymerization. The color differences between the try-in paste and the unpolymerized resin cement (ΔE00-1), the try-in paste and the polymerized resin cement (ΔE00-2), and the unpolymerized resin cement and polymerized resin cement (ΔE00-3) were calculated using the CIEDE2000 formula. Data were statistically analyzed using the two-way repeated-measures ANOVA and the Bonferroni adjustment (α = 0.05). Two-way repeated-measures ANOVA revealed no interaction between thickness and prediction method (P = .128), but both factors significantly affected ΔE00 values (P < .05). Among the thickness groups, 0.4 mm specimens showed the highest ΔE00 values (1.45 ±0.9), while 0.6 mm and 0.8 mm specimens demonstrated significantly lower ΔE00 values (P < .05). Regarding the prediction method, all groups showed statistically significant differences (P < .05), with ΔE00-1 exhibiting the highest ΔE00 value (1.38 ±0.7), followed by ΔE00-2 and ΔE00-3. In thin restorations (0.4 mm), color prediction became more challenging. Visually perceptible color differences were observed among try-in pastes and resin cements after polymerization; therefore, the use of unpolymerized resin cement yielded more reliable color prediction.