Trinh Hai Anh

Dr. Trinh Hai Anh

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
VDVan Viet Dam
Van Viet Dam
TATrinh Hai Anh
Trinh Hai Anh
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
DTDinh Hai Trinh
Dinh Hai Trinh
There are various advancements in biomaterials and methods for bone augmentation. This article aims to review the recent advances in bone augmentation for dental implants. Relevant articles on bone augmentation for dental implants were searched in PubMed/Medline, Scopus, Google Scholar, and Science Direct published in English literature published between January 1996 and March 2021. Relevant studies on bone grafts for dental implants were included and critically analyzed in this review. Various biomaterials can be used to augment bone for implant placement. Each graft procedure has advantages and disadvantages in each clinical application and needs to choose the graft material with a high success rate and less morbidity.

25 April 2022 in The Open Dentistry Journal
Verified
Journal Article
Open access
PDF file
VDVan Viet Dam
Van Viet Dam
TNThe Hanh Nguyen
The Hanh Nguyen
TATrinh Hai Anh
Trinh Hai Anh
DDDa Thi Dung
Da Thi Dung
THTrinh Dinh Hai
Trinh Dinh Hai
Background: Objective: The objective of this narrative review is to present an overview of dentin hypersensitivity and of the prevalence, etiology, mechanism, diagnosis, and clinical management.Methods: Available articles (research, reviews, commentary, views, or editorial) on hypersensitivity were searched and reviewed from January 1990 till March 2021 in Pubmed, Scopus, Google Scholar, and Science Direct. Relevant studies in English were included and critically analyzed in this article.Results: Dentin hypersensitivity causes severe pain. The most effective and least invasive remedy is using desensitizing toothpaste. In addition, based on the dentin hypersensitivity severity, management can be done professionally in-office and through self-applied at-home treatments.Conclusion: Although dentin hypersensitivity causes severe pain, it can be treated using a proper remedy. Correct diagnosis helps in the proper management of dentine hypersensitivity.Management of dentinal hypersensitivity should be done with more conservative strategies first, followed by irreversible dental interventions.

19 September 2019 in Implant Dentistry
Verified
Journal Article
Open access
TATrinh Hai Anh
Trinh Hai Anh
VDVan Viet Dam
Van Viet Dam
BLBach Le
Bach Le
PPPisha Pittayapat
Pisha Pittayapat
PTPasutha Thunyakitpisal
Pasutha Thunyakitpisal
The aim of this study was to compare the results of indirect sinus augmentation with and without the addition of a biomaterial. Thirty patients aged 40 to 60 years participated in this randomized controlled clinical trial. After closed sinus lift operation, patients were randomly and equally divided into blood clot control and acemannan14 sponge graft groups. Simultaneous implant placement was then performed. Cone beam computed tomography was performed immediately and at 3 and 6 months postoperation. Bone formation was evaluated by the radiographic endo-sinus bone gain percentage around the implant. Compared with the control group, the acemannan-treated group had a significantly greater radiographic endo-sinus bone gain percentage of approximately 2.4- and 2-fold at 3 and 6 months postsurgery, respectively (P < 0.05). The addition of a biomaterial (Acemannan) with indirect sinus augmentation and simultaneous implant placement significantly enhances bone formation at 3 and 6 months postsurgery.

14 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VSViritpon Srimaneepong
Viritpon Srimaneepong
Artak HeboyanArtak Heboyan
Artak Heboyan
Azeem Ul Yaqin SyedAzeem Ul Yaqin Syed
Azeem Ul Yaqin Syed
TATrinh Hai Anh
Trinh Hai Anh
PAPokpong Amornvit
Pokpong Amornvit
Dinesh RokayaDinesh Rokaya
Dinesh Rokaya
The loss of one or multiple fingers can lead to psychological problems as well as functional impairment. Various options exist for replacement and restoration after hand or finger loss. Prosthetic hand or finger prostheses improve esthetic outcomes and the quality of life for patients. Myoelectrically controlled hand prostheses have been used to attempt to produce different movements. The available articles (original research articles and review articles) on myoelectrically controlled finger/hand prostheses from January 1922 to February 2021 in English were reviewed using MEDLINE/PubMed, Web of Science, and ScienceDirect resources. The articles were searched using the keywords “finger/hand loss”, “finger prosthesis”, “myoelectric control”, and “prostheses” and relevant articles were selected. Myoelectric or electromyography (EMG) signals are read by myoelectrodes and the signals are amplified, from which the muscle’s naturally generated electricity can be measured. The control of the myoelectric (prosthetic) hands or fingers is important for artificial hand or finger movement; however, the precise control of prosthetic hands or fingers remains a problem. Rehabilitation after multiple finger loss is challenging. Implants in finger prostheses after multiple finger loss offer better finger prosthesis retention. This article presents an overview of myoelectric control regarding finger prosthesis for patients with finger implants following multiple finger loss.

1 September 2021 in The Open Dentistry Journal
Verified
Journal Article
Open access
PDF file
VDVan V. Dam
Van V. Dam
TATrinh Hai Anh
Trinh Hai Anh
DDDao T. Dung
Dao T. Dung
THTrinh D. Hai
Trinh D. Hai
Finite element is widely applied in dentistry to study the stress distributions on adjoining bone, the biomechanics of dental implant and bone; implant and bone interface and study its fatigue behaviors of the implant. This article presents various applications of finite element in implant dentistry. Available articles were searched and reviewed from March 1980 till September 2020 from Pubmed, Scopus, Google Scholar, and Science direct. Relevant studies were included and critically analyzed. Finite element is an important tool in implant dentistry to study the stress distributions on adjoining bone, the biomechanics of dental implant and bone; implant and bone interface, and fatigue behaviors.

4 January 2023 in Open Access Macedonian Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
DHDinh Dieu Hong
Dinh Dieu Hong
THTrinh Dinh Hai
Trinh Dinh Hai
VPVu Le Phuong
Vu Le Phuong
TATruong Thi Mai Anh
Truong Thi Mai Anh
DHDo Thi Thu Huong
Do Thi Thu Huong
TATrinh Hai Anh
Trinh Hai Anh
BACKGROUND: Dentin hypersensitivity (DH) is a short pain when dentin is exposed to external stimuli such as: Thermal, vapor, rubbing, osmotic, or chemical stimuli without pathological or any other dental defect and in normal teeth, that level of stimulation is not sufficient to cause pain. Besides tooth decay and periodontal disease, DH is the top concern of Odonto-Stomatology doctors. AIM: The aim of this study was to study the prevalence of DH in Hanoi, Vietnam, in two groups (workers at Hanvico Company and dental students at the University of Medicine and Pharmacy, VNU, Hanoi, Vietnam). MATERIALS AND METHODS: The study was conducted on 500 subjects which consisted of 288 workers at Hanvico Company and 212 Odonto-Stomatology students at the University of Medicine and Pharmacy, VNU. The study subjects were examined intraorally and diagnosed with DH to vapor and tactile stimuli using the Yeaple Probe electronic probe. RESULTS: It was found that the prevalence of DH is 20.4% in Hanoi, Vietnam, with no difference between men and women. The highest prevalence of DH is in group 40–49 years of age group. CONCLUSION: It was found that there is a moderate prevalence of DH in Hanoi, Vietnam. The cervical wear, tooth wear, gingival shrinkage, and a diet high in acid showed a high prevalence of DH.