Khadar Duale

Dr. Khadar Duale

cmpw-pan
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2020 in Polymers
Verified
Journal Article
Open access
PDF file
MZMagdalena Zięba
Magdalena Zięba
PCPaweł Chaber
Paweł Chaber
KDKhadar Duale
Khadar Duale
Magdalena Martinka MaksymiakMagdalena Martinka Maksymiak
Magdalena Martinka Maksymiak
MBMaciej Basczok
Maciej Basczok
Grazyna AdamusGrazyna Adamus
Grazyna Adamus
Periodontitis (PD) is a chronic inflammatory disease of periodontal tissues caused by pathogenic microorganisms and characterized by disruption of the tooth-supporting structures. Conventional drug administration pathways in periodontal disease treatment have many drawbacks such as poor biodistribution, low selectivity of the therapeutic effect, burst release of the drug, and damage to healthy cells. To overcome this limitation, controlled drug delivery systems have been developed as a potential method to address oral infectious disease ailments. The use of drug delivery devices proves to be an excellent auxiliary method in improving the quality and effectiveness in periodontitis treatment, which includes inaccessible periodontal pockets. This review explores the current state of knowledge regarding the applications of various polymer-based delivery systems such as hydrogels, liposomes, micro-, and nanoparticles in the treatment of chronic periodontal disease. Furthermore, to present a more comprehensive understanding of the difficulties concerning the treatment of PD, a brief description of the mechanism and development of the disease is outlined.

31 May 2007 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
BDBridgette J. Duncombe
Bridgette J. Duncombe
KDKhadar Duale
Khadar Duale
ABAnnabelle Buchanan-Smith
Annabelle Buchanan-Smith
ASAnthony J. Stace
Anthony J. Stace

2 December 2020 in Polymers
Verified
Journal Article
Open access
PDF file
ADAdrian Domiński
Adrian Domiński
TKTomasz Konieczny
Tomasz Konieczny
KDKhadar Duale
Khadar Duale
MDMonika Domińska
Monika Domińska
GPGabriela Pastuch-Gawolek
Gabriela Pastuch-Gawolek
Piotr KurcokPiotr Kurcok
Piotr Kurcok
Nanoparticles based on amphiphilic copolymers with tunable physicochemical properties can be used to encapsulate delicate pharmaceutics while at the same time improving their solubility, stability, pharmacokinetic properties, reducing immune surveillance, or achieving tumor-targeting ability. Those nanocarriers based on biodegradable aliphatic polycarbonates are a particularly promising platform for drug delivery due to flexibility in the design and synthesis of appropriate monomers and copolymers. Current studies in this field focus on the design and the synthesis of new effective carriers of hydrophobic drugs and their release in a controlled manner by exogenous or endogenous factors in tumor-specific regions. Reactive groups present in aliphatic carbonate copolymers, undergo a reaction under the action of a stimulus: e.g., acidic hydrolysis, oxidation, reduction, etc. leading to changes in the morphology of nanoparticles. This allows the release of the drug in a highly controlled manner and induces a desired therapeutic outcome without damaging healthy tissues. The presented review summarizes the current advances in chemistry and methods for designing stimuli-responsive nanocarriers based on aliphatic polycarbonates for controlled drug delivery.

29 June 2017 in Polymers
Verified
Journal Article
Open access
PDF file
Wanda SikorskaWanda Sikorska
Wanda Sikorska
Joanna RydzJoanna Rydz
Joanna Rydz
KWKatarzyna Wolna-Stypka
Katarzyna Wolna-Stypka
Marta MusiołMarta Musioł
Marta Musioł
Grazyna AdamusGrazyna Adamus
Grazyna Adamus
Marek KowalczukMarek Kowalczuk
Marek Kowalczuk
The main aim of the present study was to determine the behavior of the specimens from Ecovio, in the form of dumbbell-shaped samples and films, during degradation in selected cosmetic ingredients such as water and paraffin. The (bio)degradation test of the prototype cosmetic package (sachet) made from a PBAT (poly[(1,4-butylene adipate)-co-(1,4-butylene terephthalate)]) and PLA (polylactide) blend was investigated under industrial composting conditions, and compared with the sample behavior during incubation in cosmetic media at 70 °C. During the degradation tests, the changes of the samples were evaluated using optical microscopy, 1H NMR (proton nuclear magnetic resonance) and GPC (gel permeation chromatography) techniques. The structures of the degradation products were investigated using ESI-MSn (mass spectrometry with electrospray ionization on positive and negative ions) analysis. The thermal properties of selected materials were determined by DSC (differential scanning calorimetry) and TGA (thermogravimetric analysis) analysis. It was concluded that the PBAT and PLA blend studied had a good stability during aging in cosmetic media, and could be recommended for long-shelf-life compostable packaging of cosmetics, especially with oily ingredients.

12 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
IEItohowo Ekere
Itohowo Ekere
Brian JohnstonBrian Johnston
Brian Johnston
Fideline Tchuenbou-MagaiaFideline Tchuenbou-Magaia
Fideline Tchuenbou-Magaia
DTDave Townrow
Dave Townrow
SWSzymon Wojciechowski
Szymon Wojciechowski
Iza RadeckaIza Radecka
Iza Radecka
Presented herein are the results of a novel recycling method for waste Tetra Pak® packaging materials. The polyethylene (PE-T) component of this packaging material, obtained via a separation process using a “solvents method”, was used as a carbon source for the biosynthesis of polyhydroxyalkanoates (PHAs) by the bacterial strain Cupriavidus necator H16. Bacteria were grown for 48–72 h, at 30 °C, in TSB (nitrogen-rich) or BSM (nitrogen-limited) media supplemented with PE-T. Growth was monitored by viable counting. It was demonstrated that C. necator utilised PE-T in both growth media, but was only able to accumulate 40% w/w PHA in TSB supplemented with PE-T. Only 1.5% w/w PHA was accumulated in the TSB control, and no PHA was detected in the BSM control. Extracted biopolymers were characterised by nuclear magnetic resonance (NMR), Fourier-transform infrared (FTIR) spectroscopy, electrospray tandem mass spectrometry (ESI-MS/MS), gel permeation chromatography (GPC), and accelerator mass spectrometry (AMS). The characterisation of PHA by ESI-MS/MS revealed that PHA produced by C. necator in TSB supplemented with PE-T contained 3-hydroxybutyrate, 3-hydroxyvalerate, and 3-hydroxyhexanoate co-monomeric units. AMS analysis also confirmed the presence of 96.73% modern carbon and 3.27% old carbon in PHA derived from Tetra Pak®. Thus, this study demonstrates the feasibility of our proposed recycling method for waste Tetra Pak® packaging materials, alongside its potential for producing value-added PHA, and the ability of 14C analysis in validating this bioconversion process.

24 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
Joanna RydzJoanna Rydz
Joanna Rydz
JWJakub Wlodarczyk
Jakub Wlodarczyk
JAJennifer Gonzalez Ausejo
Jennifer Gonzalez Ausejo
Marta MusiołMarta Musioł
Marta Musioł
Wanda SikorskaWanda Sikorska
Wanda Sikorska
HJHenryk Janeczek
Henryk Janeczek
The use of (bio)degradable polymers, especially in medical applications, requires a proper understanding of their properties and behavior in various environments. Structural elements made of such polymers may be exposed to changing environmental conditions, which may cause defects. That is why it is so important to determine the effect of processing conditions on polymer properties and also their subsequent behavior during degradation. This paper presents original research on a specimen’s damage during 70 days of hydrolytic degradation. During a standard hydrolytic degradation study of polylactide and polylactide/polyhydroxyalkanoate dumbbell-shaped specimens obtained by 3D printing with two different processing build directions, exhibited unexpected shrinkage phenomena in the last degradation series, representing approximately 50% of the length of the specimens irrespective of the printing direction. Therefore, the continuation of previous ex-ante research of advanced polymer materials is presented to identify any possible defects before they arise and to minimize the potential failures of novel polymer products during their use and also during degradation. Studies on the impact of a specific processing method, i.e., processing parameters and conditions, on the properties expressed in molar mass and thermal properties changes of specimens obtained by three-dimensional printing from polyester-based filaments, and in particular on the occurrence of unexpected shrinkage phenomena after post-processing heat treatment, are presented.