Yoshiyuki Hirano

Dr. Yoshiyuki Hirano

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
YHYoshiyuki Hirano
Yoshiyuki Hirano
SKSatoshi Kodaira
Satoshi Kodaira
HSHikaru Souda
Hikaru Souda
AMAkihiko Matsumura
Akihiko Matsumura
MTMasami Torikoshi
Masami Torikoshi
Facilities for heavy ion therapies are steadily increasing in number worldwide. One of the advantages of heavy ions is their high relative biological effect (RBE). In a model used at NIRS (National Institute of Radiological Sciences), linear energy transfer (LET) spectra are required to estimate biological dose (physical dose × RBE). The CR-39 plastic charged-particle detector (CR-39) is suitable for measurement of LET. For the present study, done at the Gunma University Heavy Ion Medical Center (GHMC), we measured LET spectra at 11 depths in spread-out Bragg peak (SOBP) irradiation by a 12 C beam of 380 MeV/u. The lower threshold of the CR-39 to measure LET was about 5 keV µ m −1 due to poor sensitivity for low LET. Then we calculated biological dose and survival fraction distributions and compared them with treatment planning results at GHMC. We used Monte Carlo simulation (Geant4) to calculate LET spectra. The simulation results were in good agreement with the experimental spectra. Moreover, the biological dose and survival fraction distributions estimated from the CR-39 reproduced the treatment planning. The CR-39 is suitable for estimating biological dose in carbon ion therapy.

9 November 2019 in Medical Physics
Verified
Journal Article
Closed access
PDF file
YHYoshiyuki Hirano
Yoshiyuki Hirano
SKSatoshi Kodaira
Satoshi Kodaira
HSHikaru Souda
Hikaru Souda
KOKohei Osaki
Kohei Osaki
MTMasami Torikoshi
Masami Torikoshi

9 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SLSung Hyun Lee
Sung Hyun Lee
NSNaoki Sunaguchi
Naoki Sunaguchi
ANAkie Nagao
Akie Nagao
YHYoshiyuki Hirano
Yoshiyuki Hirano
HSHiroshi Sakurai
Hiroshi Sakurai
MTMutsumi Tashiro
Mutsumi Tashiro
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μμA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise.

23 June 2020 in Journal of Physics Communications
Verified
Journal Article
Open access
PDF file
YHYoshiyuki Hirano
Yoshiyuki Hirano
MKMasataka Komori
Masataka Komori
DODaichi Onoda
Daichi Onoda
TNTakayuki Nagae
Takayuki Nagae
SYSeiichi Yamamoto
Seiichi Yamamoto
Radioluminescence by protons and carbon ions of energy lower than the Cherenkov threshold (∼260 keV) in water has been observed. However, the origin of the luminescence has not been investigated well. In the present work, we imaged radioluminescence in water using synchrotron radiation that was of sufficiently lower energy (11 keV) than the Cherenkov threshold and we measured its spectrum using a high-sensitivity cooled CCD camera and optical longpass filters having 5 different thresholds. In addition, to determine effects of impurities in water, the water target was changed from ultrapure water to tap water. Monte Carlo simulation (Geant4) was also performed to compare its results with the experimentally obtained radioluminescence distribution. In the simulation, photons were generated in proportion to the energy deposition in water. As a result, the beam trajectory was clearly imaged by the radioluminescence in water. The spectrum was proportional to λ −3.4±0.4 under an assumption of no peaks. In the spectrum and distribution, no differences were observed between ultrapure water and tap water. TOC (total organic carbon) contents of ultrapure water and tap water as an impurity were measured and these were 0.26 mg l−1 and 2.3 mg l−1, respectively. The radioluminescence seemed to be attributable to water molecules not impurities. The radioluminescence distribution of the simulation was consistent with the experimental distribution and this suggested that radioluminescence was proportional to dose, which is expected to allow use for dose measurement.

13 November 2024 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
CPChonlada Pitakchaianan
Chonlada Pitakchaianan
KKKanyanan Kosinarkaranun
Kanyanan Kosinarkaranun
PKPantiwa Kumsut
Pantiwa Kumsut
THTatsuhide Hamasaki
Tatsuhide Hamasaki
RHRyuta Hazama
Ryuta Hazama
YKYuka Kato
Yuka Kato
This study aimed to measure tritium (3H) concentrations in Thailand. Nationwide tap water samples were collected in July 2021. Rainwater samples were collected monthly during May–October 2020, April–October 2021, and February–March 2022 in Chonburi province and in Chiang Mai province during July–November 2021, January 2022, and March–June 2022. The measurements of 3H activity concentrations were conducted by Osaka Sangyo University (OSU) and were compared with measurements by the Thailand Institute of Nuclear Technology (TINT). The results from OSU and TINT showed that 3H concentrations in tap water were matched in the ranged from 0.08 ± 0.03 to 0.28 ± 0.04 Bq L−1, while those in rainwater samples collected from Chonburi province and Chiang Mai province are also matched in the ranged from 0.11 ± 0.02 to 0.21 ± 0.03 Bq L−1 and 0.19 ± 0.02 to 0.57 ± 0.04 Bq L−1, respectively. Our measured result suggests that 3H concentration in tap water and rainwater shows a similar relation depending on latitude.

1 January 2024 in Journal of Advanced Simulation in Science and Engineering
Verified
Journal Article
Open access
PDF file
YHYoshiyuki Hirano
Yoshiyuki Hirano
TATsukasa Aso
Tsukasa Aso
YHYoshuya Horii
Yoshuya Horii
In X-ray irradiation, decreasing oxygen concentration correlates with a reduction in radiosensitivity. However, this effect is minimal in heavy ion irradiation due to the generation of oxygen along the ion track, called as the "oxygen in the heavy ion track hypothesis." We verified this hypothesis using Geant4-DNA by calculating oxygen generation and time change in distribution for 35 MeV/u and 200 MeV/u carbon ions, and 1 MeV electrons within a cell nucleus. The results showed, under hypoxic conditions (0% dissolved oxygen), the oxygen concentration increased to a maximum of 3.7% in a localized region around the track, persisting for about 100 ns after the penetration of 35 MeV/u carbon ion, while the increase for 1 MeV electrons was negligible. This finding supports the validity of the oxygen in the heavy ion track hypothesis.