1 December 2015 in Medical Physics
1 June 2018 in Journal of Physics Communications
Although luminescence of water during irradiations of proton and carbon-ion lower energy than the Cerenkov-light threshold were found recently, the sources of the luminescence were not yet obvious. To estimate the sources of the luminescence, we measured the light spectrum of the luminescence of water during carbon-ion irradiations and estimated the sources of the luminescence. Using an ultraviolet (UV) light sensitive charge coupled device (CCD) camera, we measured the luminescence images of water during carbon-ion beam irradiations by changing optical filters, derived the light spectra of the luminescence of water and compared with the calculated results. The intensity of the measured light spectrum of the luminescence of water at the Bragg peak region was decreased as the wavelength of light proportional to ~λ −2.0 where λ is the wavelength of the light, indicating the source of the luminescence of water can be electromagnetic pulse produced by the dipole displacement inside the water molecules. In the shallow part of the water prior to the Bragg peak, where the Cerenkov-light is included, the spectrum showed steeper curve that is proportional to ~λ −2.6, which was similar to the calculated spectrum of Cerenkov-light including the refractive index changes of water with the wavelength of light. From these results, the luminescence of water is thought to be mainly come from electromagnetic pulse produced by the dipole displacement inside the water molecules.
13 March 2009 in Physics in Medicine & Biology
The pencil-beam algorithm is valid only when elementary Gaussian beams are small enough compared to the lateral heterogeneity of a medium, which is not always true in actual radiotherapy with protons and ions. This work addresses a solution for the problem. We found approximate self-similarity of Gaussian distributions, with which Gaussian beams can split into narrower and deflecting daughter beams when their sizes have overreached lateral heterogeneity in the beam-transport calculation. The effectiveness was assessed in a carbon-ion beam experiment in the presence of steep range compensation, where the splitting calculation reproduced a detour effect amounting to about 10% in dose or as large as the lateral particle disequilibrium effect. The efficiency was analyzed in calculations for carbon-ion and proton radiations with a heterogeneous phantom model, where the beam splitting increased computing times by factors of 4.7 and 3.2. The present method generally improves the accuracy of the pencil-beam algorithm without severe inefficiency. It will therefore be useful for treatment planning and potentially other demanding applications.
1 June 2018 in Physics in Medicine & Biology
Although luminescence of water lower in energy than the Cerenkov-light threshold during proton and carbon-ion irradiation has been found, the phenomenon has not yet been implemented for Monte Carlo simulations. The results provided by the simulations lead to misunderstandings of the physical phenomenon in optical imaging of water during proton and carbon-ion irradiation. To solve the problems, as well as to clarify the light production of the luminescence of water, we modified a Monte Carlo simulation code to include the light production from the luminescence of water and compared them with the experimental results of luminescence imaging of water. We used GEANT4 for the simulation of emitted light from water during proton and carbon-ion irradiation. We used the light production from the luminescence of water using the scintillation process in GEANT4 while those of Cerenkov light from the secondary electrons and prompt gamma photons in water were also included in the simulation. The modified simulation results showed similar depth profiles to those of the measured data for both proton and carbon-ion. When the light production of 0.1 photons/MeV was used for the luminescence of water in the simulation, the simulated depth profiles showed the best match to those of the measured results for both the proton and carbon-ion compared with those used for smaller and larger numbers of photons/MeV. We could successively obtain the simulated depth profiles that were basically the same as the experimental data by using GEANT4 when we assumed the light production by the luminescence of water. Our results confirmed that the inclusion of the luminescence of water in Monte Carlo simulation is indispensable to calculate the precise light distribution in water during irradiation of proton and carbon-ion.
12 December 2008 in Physical Review C
We have studied the production of the projectile-like fragments and produced in interactions of 200 to 400 MeV/nucleon carbon ions with water, using emulsion detectors. In this Brief Report we present the first published production cross section of the projectile-like fragment in the energy region above 100 MeV/nucleon. The measured production cross sections of these nuclides were compared to calculations using a semiempirical model. We found that the measured cross sections deviate from the calculated values by a factor up to about six. This information is of importance for benchmarking and improving heavy ion nuclear reaction models.
3 August 2011 in Physics in Medicine & Biology
We aimed to estimate the scattered radiation from dental metallic crowns during head and neck radiotherapy by irradiating a jaw phantom with external photon beams. The phantom was composed of a dental metallic plate and hydroxyapatite embedded in polymethyl methacrylate. We used radiochromic film measurement and Monte Carlo simulation to calculate the radiation dose and dose distribution inside the phantom. To estimate dose variations in scattered radiation under different clinical situations, we altered the incident energy, field size, plate thickness, plate depth and plate material. The simulation results indicated that the dose at the incident side of the metallic dental plate was approximately 140% of that without the plate. The differences between dose distributions calculated with the radiation treatment-planning system (TPS) algorithms and the data simulation, except around the dental metallic plate, were 3% for a 4 MV photon beam. Therefore, we should carefully consider the dose distribution around dental metallic crowns determined by a TPS.